If an emergency (or anti-entrapment) switch is
desired in the vestibule, then wire that switch directly
to one of the operator inputs. Usually the exterior
door is used in this case.
Once the desired operation is achieved, proceed to
Section 4, for
System Inspection Instructions
.
Section 4 _________________
System Inspection Instructions
After the Installation and operational check of the
system:
1. Place warning label on the door (as per ANSI
A156.10 or A156.19 guidelines). This will
advise the person entering the swing side
zone that the door will move.
2. Instruct the owner on door system operation
and how to test it. This should be checked
on a daily basis.
3. Instruct the owner on what to do if the door or
any of its components become damaged.
4. Strongly recommend to the owner that the
complete entry be inspected twice a year as
part of the service agreement.
Section 5_________________
Technical Data
Model
CX-29
Size
3 ¼” x 2 ¼” x ¾”
Mounting
Velcro or double-sided tape
Enclosure
Protective paper sleeve.
Operating voltage
12 / 24 Volts, AC / DC
Current Draw
18 mA standby,
40 mA max.
Response time
0.3 seconds
Inputs
2 x “dry” contacts,
2 x “wet” contacts:
(3-30 V AC/DC, Optically
isolated, non-polarity
sensitive).
Relay Output
2 x Form C (SPDT)
Relay contact rating
3 amps @ 20 VDC
Time Delays
DOR #1 1 to 30 seconds
DOO # 2 1 to 30 seconds
DOR #2 1
– 30 seconds
Electrical Life
1,000,000 operations
@ ½ rated capacity
Section 6_________________
Warranty
Camden Door Controls guarantees the CX-29 to be
free from manufacturing defects for 3 years from date
of sale. If during the first 3 years the
CX-29 fails to perform correctly, it may be returned to
our factory where it will be repaired or replaced (at
our discretion) without charge. Except as stated
herein, Camden extends no warranties expressed or
implied regarding function, performance or service.