If  an  emergency    (or  anti-entrapment)  switch  is 
desired in the vestibule, then wire that switch directly 
to  one  of  the  operator  inputs.  Usually  the  exterior 
door is used in this case. 

 

Once  the  desired  operation  is  achieved,  proceed  to 
Section 4, for 

System Inspection Instructions

 

Section 4 _________________ 
System Inspection Instructions 

After  the  Installation  and  operational  check  of  the 
system: 

1.  Place warning label on the door (as per ANSI 

A156.10  or  A156.19  guidelines).    This  will 
advise  the  person  entering  the  swing  side 
zone that the door will move. 

2.  Instruct  the  owner  on  door  system  operation 

and  how  to  test  it.    This  should  be  checked 
on a daily basis. 

3.  Instruct the owner on what to do if the door or 

any of its components become damaged. 

4.  Strongly  recommend  to  the  owner  that  the 

complete  entry  be  inspected  twice  a  year  as 
part of the service agreement. 

Section 5_________________ 
Technical Data 

Model   

 

CX-29 

Size 

 

 

3 ¼” x 2 ¼” x ¾” 

Mounting 

 

Velcro or double-sided tape 

Enclosure 

 

Protective paper sleeve. 

Operating voltage  

12 / 24 Volts, AC / DC 

Current Draw 

18 mA standby, 
40 mA max. 

Response time   

0.3 seconds 

Inputs   

 

2 x “dry” contacts,  

                                       

2 x “wet” contacts: 

                                         (3-30 V AC/DC, Optically 
                                         isolated, non-polarity 
                                         sensitive). 

Relay Output 

 

2 x Form C (SPDT) 

Relay contact rating 

3 amps @ 20 VDC 

Time Delays 

DOR  #1   1 to 30 seconds 
DOO # 2   1 to 30 seconds 
DOR  #2   1 

– 30 seconds 

Electrical Life 

1,000,000 operations 
@ ½ rated capacity 

 

 

Section 6_________________ 
Warranty 

Camden  Door  Controls  guarantees  the  CX-29  to  be 
free from manufacturing defects for 3 years from date 
of  sale.    If  during  the  first  3  years  the 
CX-29 fails to perform correctly, it may be returned to 
our  factory  where  it  will  be  repaired  or  replaced  (at 
our  discretion)  without  charge.    Except  as  stated 
herein, Camden extends no  warranties expressed or 
implied regarding function, performance or service. 

Questions? 

Call us toll-free at 1-877-226-3369 

Page 3 of 8 

Part number: 40-82B134 
Filename: CX-29 Instructions.doc 
Revision: 11/29/2011 1:28 PM 

Содержание CX-29

Страница 1: ...hout fear of malfunction SEE DIAGRAM 01 Additionally we provide a direct connection from an apartment interphone panel Only Relay 1 strike will operate when a voltage is applied to this input A vestib...

Страница 2: ...elay and the operator relay is adjusted by DOO RL2 and the hold open time for the operator is adjusted by pot DOR RL2 Connect the door position switch to DRY 2 Terminals 15 16 The switch can be a magn...

Страница 3: ..._______ Technical Data Model CX 29 Size 3 x 2 x Mounting Velcro or double sided tape Enclosure Protective paper sleeve Operating voltage 12 24 Volts AC DC Current Draw 18 mA standby 40 mA max Response...

Страница 4: ...uring 5502 Timberlea Blvd Mississauga Ontario L4W 2T7 12 24 V AC DC Power Dry Input ie Push Switch Wet Input ie Radio Receiver Electric Strike Door Operator MOV Wire MOV supplied directly to strike or...

Страница 5: ...T7 12 24 V AC DC Power Electric Lock MOV Wire MOV supplied directly to strike or magnet Power for Strike Fire Alarm Panel with Wet output Select N O Mode 2 N C Mode 3 optional Wall Switch FIRE If usin...

Страница 6: ...12 24 V AC DC Power Optional Vestibule mounted Convenience Switch Only active when Lock relay energized Switch opens door Electric Strike Door Operator MOV Wire MOV supplied directly to strike or mag...

Страница 7: ...ence Switch Only active when Lock relay energized Switch opens door Electric Strike Door Operator MOV Wire MOV supplied directly to strike or magnet Power for Strike Apartment Interphone Panel DRY con...

Страница 8: ...TE 04 14 11 Camden Door Controls 5502 Timberlea Blvd Mississauga Ontario L4W 2T7 12 24 V AC DC Power Door 2 Push Switch Door 2 Operator Door 1 Operator Wet output ie RF receiver optional Wet output ie...