Camco OLYMPIAN Wave3 Скачать руководство пользователя страница 8

8

OPERATING INSTRUCTIONS (cont.)

Red Glowing on Heating Element

The red glowing on the face of the heater (particularly noticeable in the dark) will 
resemble charcoal glowing when hot. This is a normal phenomenon of catalization. 
A properly operating heater will slightly “glow” on about 40% of the bottom area 
of the heating element. At times, a high glow “spot” may be seen on the heating 
element. This is normal. The glowing phenomenon diminishes over a period of years 
usage.

CARE OF HEATER

General

•  Any changes or alterations to this heater or its controls (or 

attempts to clean the catalytic pad) can result in damage, 
compromised operation, decreased performance and /or 
risk of accident.

•  Alterations to the heater or its control can result in the 

heater’s faulty operation, which may create hazardous 
conditions.

•  If the instructions in this manual are not followed exactly, 

a fire or explosion many result causing property damage, 
personal injury or loss of life.

Cleaning

The heater and its surroundings should be kept clean and 
free of dust.

•  It is recommended that the heater be kept covered at all 

times when not in use. Custom-made dust covers are 
available from the factory or your local dealer (see chart 
below for part number). DO NOT COVER HEATER WHILE 
IT IS HOT.

 

Wall Mounted 

Portable

Wave 3 

57706 

57722

Wave 6 

57713 

57723

Wave 8 

57715 

57724

•  The exterior of the heater can be cleaned with a damp 

cloth. Avoid the direct use of any aerosol or spray-on 
cleaners. Do not use abrasive material or cleaners on the 
decals or control knob. Take care not to get moisture, 
cleaners or solvents on the catalytic element surface.

•  Never touch, vacuum or wash off the catalyst pad. This 

may destroy the active catalytic platinum surface and 
make the pad inoperable.

Off Season

•  If the heater is to be left “OFF” for a considerable period of 

time, the propane (LP) gas supply to the heater should be 
turned off as close to the gas source as possible. 

•  In the case of portable use, the gas should be turned off 

at the propane (LP) supply cylinder.

•  In the case of wall-mounted heaters, there should be a 

manual gas valve installed near the heater.

Service

With good care and normal operating conditions, your 
Olympian™ Catalytic Heater should provide many years of 
warmth and comfort.

The following service tips will assist you in taking 
care of the heater.

•  Locate and use the heater where it is least likely to be 

subject to impact, exposure to adverse weather or in 
direct contact with cooking products or cleaning agents.

•  The gas supply system to the heater should be checked 

periodically by a qualified LP Gas service technician. If 
the heater will not light, will not stay lit, or does not put 
out the normal amount of heat, the very first thing to do 
is check the gas supply. Find out if the gas is available 
at the heater. Check LP Gas regulator to ensure correct 
manifold pressure.

•  Operation of the heater should be checked by a qualified 

LP Gas service technician when the heater has been 
out of service for a considerable period (intermittent 
operation) and in any event at least once a year.

•  For continued high efficiency operation, it is 

recommended that the catalyst pad be replaced every 
seven years, 

and sooner if abnormal operation of the 

pad is noticed

.

 Catalyst pad replacement must be done at 

the factory or by a certified LP Gas technician.

•  The heater has no moving parts except in the gas supply 

and control system. Because of this, part replacement is 
minimal and only a few parts can be replaced in the field. 
The parts described herein can be easily replaced in the 
field.

•  Users should not attempt to repair or change any parts of 

the heater. All repairs must be performed at the factory or 
by a qualified LP Gas technician.

Piezo Electric Igniter

If no spark is obtained when the igniter button is pressed 
several times, the Piezo Igniter (Part #57800) or Ceramic Spark 
Plug (Part #57784) may need replacement. These parts are 
available through the factory.

Содержание OLYMPIAN Wave3

Страница 1: ... in a place that will block the heat rays Your Olympian heater has undergone rigorous safety performance and quality assurance testing before leaving the factory It is designed to deliver years of trouble free service The INSTALLER must leave this set of instructions with the owner after installation is completed IMPORTANT Installers must have the owner fill out and mail the warranty card supplied...

Страница 2: ...your gas supplier LP Gas Warning Odor If a gas leak happens you should be able to smell the gas because of the odorant put in the LP Gas That s your signal to go into immediate action Do not operate electric switches light matches or use your phone Don t do anything that could ignite the gas Get everyone out of the building vehicle trailer or area IMMEDIATELY Close all gas tank or cylinder supply ...

Страница 3: ... it goes completely empty or by having it refilled before it is completely empty SAFETY INFORMATION FOR USE OF LP GAS cont SAFETY INFORMATION FOR USE OF LP GAS cont Gas Supply The installation must conform to local codes In the absence of local codes the installation must conform with American National Standard National Fuel Gas Code known as NFPA 54 and ANSI Z223 1 2002 or the latest edition Avai...

Страница 4: ...e installed in a variety of fixed locations It also may be used as a portable heater by using optional leg stands Consistent with other requirements keep the gas supply line from the tank to the heater as short as possible The installation including that of the gas supply system must conform with all applicable state and local codes and with the National Fuel Gas Code ANSI Z223 1 Installation shou...

Страница 5: ...e back of the case is 1 3 4 This is the maximum recess depth 5 Using the ring as a template carefully drill 7 64 diameter screw holes through the heater case at the side and top Be careful of internal gas lines 6 Fasten the recess mounting ring to the heater case using the 6 x 3 8 lg panhead tapping screws included in the recess mounting kit 7 Fasten the heater and mounting ring assembly to the wa...

Страница 6: ...ul burns Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any p...

Страница 7: ...eep the gas valve open 7 When ignition occurs you will see small blue flames dancing over the catalyst pad face while it heats up This flaming is normal during start up of the heater as this begins the catalytic combustion process Flaming may occur several times during the heating up period 8 Release the control knob push know in slightly and immediately turn it to HIGH heat setting Done properly ...

Страница 8: ...hould be turned off as close to the gas source as possible In the case of portable use the gas should be turned off at the propane LP supply cylinder In the case of wall mounted heaters there should be a manual gas valve installed near the heater Service With good care and normal operating conditions your Olympian Catalytic Heater should provide many years of warmth and comfort The following servi...

Страница 9: ...pane Use of other LP Gases such as those too high in sulfur propylene or other hydrocarbons may injure the catalyst pad Gas or sludge from the inside of old or dirty cylinders may block out the catalyst and prevent it from working Dirty or improper gas may plug the orifice and restrict the gas supply to the catalyst pad Symptoms of this are Heater won t light or will only light partially Gas odor ...

Страница 10: ...ter model and serial number The heater is designed as a non vented gas fired space heater Such heaters have many uses in residential agricultural industrial trade service and recreational applications Its use is intended for purposes described and limited by any applicable standards Camco cannot anticipate all of the many applications for which catalytic heaters may be used This heater should not ...

Страница 11: ...s liability for indirect or consequential damage to property Warranty repairs must be made by Camco Mfg Inc Leg Stands To make Olympian Wave heaters portable Leg stands fit all heaters models Wave 3 Wave 6 and Wave 8 Part No 57701 Custom Fitted Dust Covers Model Part No For wall mount heaters Wave 3 57706 Wave 6 57713 Wave 8 57715 For portable heaters with leg stands Wave 3 57722 Wave 6 57723 Wave...

Страница 12: ...s Chrome Recess Kit for Wave 6 57692 22 95 Chrome Recess Kit for Wave 8 57695 27 55 subtotal 6 75 Sales Tax NC Residents only Shipping Handling TOTAL Payment Method Check MasterCard _ ___________________________________ VISA __________________________________________ Card Expiration Date ______________________________ Signature _________________________________________ Ship to Name _______________...

Отзывы: