Camco OLYMPIAN Wave3 Скачать руководство пользователя страница 6

6

OPERATING INSTRUCTIONS

IMPORTANT: 

On initial lighting from a cold start, a 

slight odor or propane smell may be noticed for a short 
period of time. This is normal. If odor persists, do not 
continue to use heater. Shut the heater off and have it 
serviced.

IMPORTANT: When operating the heater in the 
horizontal position, it is harder to start than when it is in 
the vertical position. Because of this, it may take longer 
for complete ignition to occur, and the propane odor 
may last for a longer period. If, however, it does not go 
away, the heater should be shut off and serviced.

After heater is turned off, wait at least 5 minutes before 
relighting the heater.

If the heater is to be left OFF for a considerable period of 
time, the gas supply to the heater should be turned off as 
close to the gas source as possible (See illustration on  
pg. 3 under Gas Supply).
In the case of wall-mounted heaters, this can be at the 
manual gas valve near the heater or further upstream (See 
illustration on pg. 3 under Gas Supply).
In the case of portable use, the gas should be turned off at 
the LP Gas storage cylinder valve. 
Do not attempt to service or clean heater while it is hot. 
Failure to follow this instruction can result in painful burns.

Use only your hand to push in or turn the gas control 
knob. Never use tools. If the knob will not push in or 
turn by hand, don’t try to repair it; call a qualified 
service technician. Force or attempted repair may 
result in a fire or explosion.

Do not use this appliance if any part has been under 
water. Immediately call a qualified service technician 
to inspect the appliance and to replace any part of the 
control system and any gas control that has been under 
water.

Air Supply

This heater consumes air from the room in which it is 
installed. To assure complete combustion, an adequate 
fresh-air supply to the room is necessary.

 

It is good 

practice to have at least two openings, one high and one 
low. The room must have a total of at least 24 square inches 
free-air opening (i.e. an opening of 4" x 6"=24 square inches). 
Provide additional ventilation of at least 2 square inches for 
every 1,000 BTUs per hour of input for any additional fuel 
burning appliances used at the same time. If the room is 
tightly sealed or insulated so that natural infiltration is low, 
additional ventilation is required (see below).

Some shelter materials such as fabric tents are often 
thought of as not being airtight, but do become almost 
impervious to air and gas passage when wet or covered 
with snow. Special precautions must be taken to provide 
enough air for efficient combustion and for breathing by the 
occupants (see above).

Содержание OLYMPIAN Wave3

Страница 1: ... in a place that will block the heat rays Your Olympian heater has undergone rigorous safety performance and quality assurance testing before leaving the factory It is designed to deliver years of trouble free service The INSTALLER must leave this set of instructions with the owner after installation is completed IMPORTANT Installers must have the owner fill out and mail the warranty card supplied...

Страница 2: ...your gas supplier LP Gas Warning Odor If a gas leak happens you should be able to smell the gas because of the odorant put in the LP Gas That s your signal to go into immediate action Do not operate electric switches light matches or use your phone Don t do anything that could ignite the gas Get everyone out of the building vehicle trailer or area IMMEDIATELY Close all gas tank or cylinder supply ...

Страница 3: ... it goes completely empty or by having it refilled before it is completely empty SAFETY INFORMATION FOR USE OF LP GAS cont SAFETY INFORMATION FOR USE OF LP GAS cont Gas Supply The installation must conform to local codes In the absence of local codes the installation must conform with American National Standard National Fuel Gas Code known as NFPA 54 and ANSI Z223 1 2002 or the latest edition Avai...

Страница 4: ...e installed in a variety of fixed locations It also may be used as a portable heater by using optional leg stands Consistent with other requirements keep the gas supply line from the tank to the heater as short as possible The installation including that of the gas supply system must conform with all applicable state and local codes and with the National Fuel Gas Code ANSI Z223 1 Installation shou...

Страница 5: ...e back of the case is 1 3 4 This is the maximum recess depth 5 Using the ring as a template carefully drill 7 64 diameter screw holes through the heater case at the side and top Be careful of internal gas lines 6 Fasten the recess mounting ring to the heater case using the 6 x 3 8 lg panhead tapping screws included in the recess mounting kit 7 Fasten the heater and mounting ring assembly to the wa...

Страница 6: ...ul burns Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any p...

Страница 7: ...eep the gas valve open 7 When ignition occurs you will see small blue flames dancing over the catalyst pad face while it heats up This flaming is normal during start up of the heater as this begins the catalytic combustion process Flaming may occur several times during the heating up period 8 Release the control knob push know in slightly and immediately turn it to HIGH heat setting Done properly ...

Страница 8: ...hould be turned off as close to the gas source as possible In the case of portable use the gas should be turned off at the propane LP supply cylinder In the case of wall mounted heaters there should be a manual gas valve installed near the heater Service With good care and normal operating conditions your Olympian Catalytic Heater should provide many years of warmth and comfort The following servi...

Страница 9: ...pane Use of other LP Gases such as those too high in sulfur propylene or other hydrocarbons may injure the catalyst pad Gas or sludge from the inside of old or dirty cylinders may block out the catalyst and prevent it from working Dirty or improper gas may plug the orifice and restrict the gas supply to the catalyst pad Symptoms of this are Heater won t light or will only light partially Gas odor ...

Страница 10: ...ter model and serial number The heater is designed as a non vented gas fired space heater Such heaters have many uses in residential agricultural industrial trade service and recreational applications Its use is intended for purposes described and limited by any applicable standards Camco cannot anticipate all of the many applications for which catalytic heaters may be used This heater should not ...

Страница 11: ...s liability for indirect or consequential damage to property Warranty repairs must be made by Camco Mfg Inc Leg Stands To make Olympian Wave heaters portable Leg stands fit all heaters models Wave 3 Wave 6 and Wave 8 Part No 57701 Custom Fitted Dust Covers Model Part No For wall mount heaters Wave 3 57706 Wave 6 57713 Wave 8 57715 For portable heaters with leg stands Wave 3 57722 Wave 6 57723 Wave...

Страница 12: ...s Chrome Recess Kit for Wave 6 57692 22 95 Chrome Recess Kit for Wave 8 57695 27 55 subtotal 6 75 Sales Tax NC Residents only Shipping Handling TOTAL Payment Method Check MasterCard _ ___________________________________ VISA __________________________________________ Card Expiration Date ______________________________ Signature _________________________________________ Ship to Name _______________...

Отзывы: