4
.1
Communications
Menu Definitions
:
R
1
Baud Rate 1200 to 115200 baud (9600), 8, n, 1
R
2
Output 0 - (Gross, Tare, Net)- "CR, LF, CR, LF [32 bytes of 2Eh],
Format
CR, LF, CR, LF, Gross (lb or kg), :, six ASCII characters
[indicated weight], CR, LF, Tare (lb or kg), sp, :, six
ASCII characters (indicated weight), CR, LF, CR, LF, CR
LF, CR, LF" [100 bytes total output
]
.
1 - (Weight only)- "Six ASCII Characters [indicated weight],
CR, LF" [8 bytes total output].
2 - (Net only)- "NT, Sp, Six ASCII Characters [indicated
weight], Sp, lb or kg, CR, LF" [14 bytes total output].
3 - (Gross only)- "GR, Sp, Six ASCII Charactes [indicated
weight], Sp, lb or kg, CR, LF" [14 bytes total output].
R
3
Output Type 0 - Output on command, standard print.
Output as selected by R2 Output Format.
If "Q" is received on the serial port the scale will output
the same as if the PRINT key were Pressed.
The same holds true for Z = Zero
U = lb/kg
D = GRS/NET
T = TARE
1 - Slave Display Output (numeric only) continuous
Stx, Six ASCII Characters (indicated weight), CR, LF
[9 bytes total output].
2 - Slave Display Output (alphanumeric) continuous
Stx GR or NT or TR, six ASCII Characters (indicated
weight), lb or kg, CR, LF [15 bytes total output].
3 - RF Link Output.
4 - Used for QSI terminal.
4
.0 COMMUNICATIONS SETUP
CAMBRIDGE SCALE WORKS, INC.
12
MANUAL P/N 5999-1014-01