background image

Page 15 of 16 

 

Configuring the Link 

The Web EMS provides wizards to configure radio links. The wizards guide you through configuration of the basic radio 
parameters and services necessary to establish a working pipe link.  

To configure a 1+0 link using the Quick Configuration wizard, select Quick Configuration > PIPE > Single Carrier > 1+0. 
Page 1 of the 1+0 Quick Configuration wizard opens. 

 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

Set the transmission and 

received radio frequency in MHz.

Enter the desired TX signal level 

(TSL). The range of values depends 

on the frequency and RFU type.

Select 

On 

or 

Off 

to mute or 

unmute the TX output of the RFU.

Select the MRMC script you want 

to assign to the radio.

Select the ACM mode: 

Fixed 

or 

Adaptive

.

If you selected 

Fixed 

in the 

Operational Mode 

field, the 

Profile 

field 

appears instead of these fields. Select the ACM profile for the radio in 

the 

Profile 

field.

If you selected 

Adaptive 

in the 

Operational Mode 

field, enter the 

maximum and minimum profiles for the script in these fields.

• 

Fixed ACM mode applies constant TX and 

RX rates.

• 

In Adaptive ACM mode, TX and RX rates are 

dynamic. An ACM-enabled radio system 

automatically chooses which profile to use 

according to channel fading conditions.

Select 

Yes 

to configure in-band 

management or 

No 

if you do not 

need in-band management.
If you selected 

Yes 

above, select 

the management VLAN.

Select this box if you want to use the 

Ethernet interface as well as the radio 

interface for in-band management.

Review the parameters and click 

Submit 

to 

complete configuration of the link. After you 

click 

Submit

, the unit is reset.

2

3

4

5

Select the Attached Interface type for 

the service that will connect the radio 

and Ethernet interfaces:

Select a radio 

interface for the link.

Select an Ethernet interface or LAG for the link. 

Click 

Create LAG 

to open a wizard that guides 

you through the steps to create a LAG. 

• 

s-tag

 – All S-VLANs and untagged 

frames are classified into the service.

• 

dot1q

 – All C-VLANs and untagged 

frames are classified into the service.

1

Содержание PTP 820E

Страница 1: ...Quick Installation Instructions PTP 820E System Release 10 9 ...

Страница 2: ...terial Accordingly any copyrighted material of Cambium its licensors or the 3rd Party software supplied material contained in the Cambium products described in this document may not be copied reproduced reverse engineered distributed merged or modified in any manner without the express written permission of Cambium Furthermore the purchase of Cambium products shall not be deemed to grant either di...

Страница 3: ...ore detailed instructions Installation Guide for PTP 820E Detailed instructions for hardware assembly of all supported PTP 820E link types User Guide for PTP 820C PTP 820S and PTP 820E Detailed instructions for software configuration PTP 820E Rear View Left and Front View Right PTP 820E Interfaces Cable Gland Construction ...

Страница 4: ...Page 4 of 16 PoE Injector PoE Injector Interfaces ...

Страница 5: ...e the transparent pressure window located on the antenna interface For horizontal polarization locate the twist with the letter H at 3 o clock and fasten the two screws For vertical polarization locate the twist with the letter V at 3 o clock and fasten the two screws ...

Страница 6: ...ntenna using the four M8 captive screws and washers that are supplied assembled in the PTP 820E and tighten the screws When tightening the captive screws use 20 Nm torque In order to avoid misalignment screws should be tightened progressively ...

Страница 7: ...Page 7 of 16 Cabling To connect an optical Ethernet cable and SFP ...

Страница 8: ...Page 8 of 16 To connect an electrical Ethernet cable To connect a DC power cable ...

Страница 9: ...No grounding is required for optical SFP cables External shielded CAT5E cable should be grounded to the antenna tower at the top next to the PTP 820 unit and the bottom of the external run and every 50m using the kit CAT5E_gnd_kit ...

Страница 10: ...nt and tighten the PoE Injector to a wall using two M6 bolts and anchors Use Anchor Stainless Steel with flanged Hexagonal nut M6X70 1 2 Drill two 6mm diameter holes with 100mm between the center of the holes Insert the anchors with the bolts place the washers on the bolts and tighten the nuts 3 ...

Страница 11: ...the adaptor through the wall mounting holes using M6 screws and washers 4 2 Connect ETSI adapting ears to a 19 rack adaptor using four M6 screws Mount the 19 rack adaptor with the ETSI ears on the ETSI rack using four M6 screws and cage nuts To ground a PoE Injector 1 On the right side of the PoE Injector loosen the screw plain washer and serrated washer 2 Place the cable lug supplied with the PoE...

Страница 12: ...cordance with applicable national code and regulations rated maximum 20A shall be installed for full power disconnection in a building installation Any outdoor antenna cable shield shall be permanently connected to protective earth in a building installation Connecting to the Unit 1 Connect your laptops LAN port to the MGT port on the PTP 820E 2 Configure an IP address on the laptop within the sam...

Страница 13: ...e opens Select IPv4 or IPv6 The unit will use the selected protocol when initiating communications Description of unit optional You can enter an IP address in IPv4 format use the IP address field or IPv6 format use the IPv6 Address field Before configuring the radio link ensure that both ends of the link have unique IP addresses ...

Страница 14: ...ays a yellow background and an activation key violation warning After a 48 hour grace period all other alarms are hidden until the capacity and features in use are brought within the activation key s capacity and feature set Demo mode is available which enables all features for 60 days When demo mode expires the most recent valid activation key goes into effect To enter a new activation key select...

Страница 15: ...ional Mode field enter the maximum and minimum profiles for the script in these fields Fixed ACM mode applies constant TX and RX rates In Adaptive ACM mode TX and RX rates are dynamic An ACM enabled radio system automatically chooses which profile to use according to channel fading conditions Select Yes to configure in band management or No if you do not need in band management If you selected Yes...

Страница 16: ... the voltage measured at the BNC port is not accurate and should be used only as an aid Verify that the Radio Bit Error Rate BER is 10E 11 or higher If working with ATPC verify that ATPC is operating as expected RSL reference level To display the BER using the Web EMS go to the Aggregate PM report Radio PM Statistics Aggregate To display the current RSL RX using the Web EMS go to the Radio Paramet...

Отзывы: