Chapter 8: Installation Instructions for Configurations with Channe
Filter-Based Branching
Channel Filter-Based Branching – Configurations
Page 8-126
Procedure
1.
Assemble the OCU Mounting Kit. See
Assembling the OCU Mounting Kit
2.
Assemble two OCUs, both using a Left Rail Configuration. Attach an PTP 820C HP radio to each
OCU, and connect the radio-OCU assemblies to the Branching Pole Profile as shown in the
following figure. See
Assembling the OCU
.
Left
(1)
Left
(2)
3.
Connect the OMT to the antenna. See Steps 1-4 in
2+0 Dual Polarization Remote Mount.
4.
On the side of the OCU facing the pole, attach a Termination to each of the four radio ports. See