![Cambium Networks PMP 450 Series Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/cambium-networks/pmp-450-series/pmp-450-series_release-notes_3729927048.webp)
Release Notes
System Release 13.4
pmp-0979 - July 2015
Page
48 of
50
Products
Affected
Tracking
Description
All
CPY-10687
False radar detection on 5.x GHz ETSI & FCC AP for 10, 7
and 5 MHz Channel band width. If false radar detections
occur, set the SM receive target level to a lower value to
reduce the impact.
PMP/PTP
450 5.4
GHz
CPY-10763
ETSI LBT is not supported on radios using a 5ms frame.
PMP 450
AP
CPY-10846
Some of the SM OIDs listed in the WHISPSM MIB will also
work on APs.
PMP 430
AP
CPY-11040
PMP 430 APs might have a "Cannot update rcvd quality with
invalid LUID 1" error. Please contact Cambium Support if
your PMP 430 AP displays this error.
PMP 450
CPY-11057
QinQ configuration does not work with VLAN ID “1”.
PTP 450
CPY-11299
In ETSI regions, users might see their BHS transmit at a
lower power after an LBT event.
All
CPY-11466
SNMP object regFailSeqNum returns value type integer
instead of counter32