Chapter 5: Installation
Installing external antennas to a connectorized
ODU
Page
39
Attaching the PMP 450 Series AP and antenna to the mount point
1
Attach the upper bracket of the antenna to the mount point by closing the rear strap around the
pole and tightening the (2) serrated flange nuts using a 13mm spanner wrench. These must be
tightened evenly on the pol to avoid jumping/stripping threads.
Figure 106 Attaching the AP antenna upper bracket to the pole
2
Attach the lower bracket of the antenna to the mount point by closing the rear strap around the
pole and tightening the (2) serrated flange nuts using a 13mm spanner wrench. These must be
tightened evenly on the pole to avoid jumping/stripping threads.
Figure 107 Attaching the AP antenna lower bracket to the pole
3
Use a local map, compass, and/or GPS device as needed to determine the direction that one or
more APs require to each cover the 90° sector.