This option allows users to choose whether the radio pop a dialog box to alert user
when the temperature is too high for radio to work in current channel.
This option only allows users to check whether to alert user, when temperature is
very high. The radio will detect temperature all the time in despite of whether user has
checked this option.
Note: the Local Alarm On/Off is unchecked, this item can not available.
Forward Power
This option allows users to choose to alert user of potential PA failure.
When the forward power is below the Low Forward Power, a warning will be indicated
to user via the display as long as the Forward Power option is enabled
When the forward power value is measured to be zero, the PA power will be cutoff
immediately regardless the setting value in this field and alarm.
This option only allow users to check whether to alert user, when the forward power is
low. The radio will detect forward power periodically during transmission in despite of
whether user has checked this option.
Tx PLL Unlock
This option alerts users to choose whether the radio pop a dialog box to alert user
when the transmission is Unlock for radio to work in current channel.
Rx PLL Unlock
This option allows users to set whether the repeater will give users an alert when the
RX PLL unlocks.
Over/Low Voltage
This option alerts users when the voltage is too high or too low for radio to work.
This option only alert users when voltage is abnormal. The radio will detect voltage
and protect itself all the time regardless of whether or not this option is checked.
Fan Control Setting
Fan Control Mode
To Select fan control mode
Always On: the fan keep on always.
Temperature Control:the fan on or off depend on the repeater current work
temperature.