Safety Summary

To avoid personal injury and/or product damage, review and comply with 

the following safety precautions. These precautions apply to both operating 

and maintenance personnel and must be followed during all phases of 

operation, service, and repair of this probe.

WARNING

 statement calls attention to an operating procedure, 

practice, or condition, which, if not followed correctly, could result in injury 

or death to personnel.

CAUTION

 statement calls attention to an operating procedure, practice, 

or condition, which, if not followed correctly, could result in damage to or 

destruction of parts or the entire product. 

Do Not Work Alone

Do not work alone when working with high voltages.

Inspect the Probe

Inspect the probe and accessories for cracks and frayed or broken leads 

before each use. If defects or damages are noted, DO NOT USE the 

probe.

Dry Conditions

Hands, shoes, floor, and work bench must be dry. Avoid making 

measurements under humidity, dampness, or other environmental 

conditions that might affect safety.

Do Not Remove the Probe’s Casing

Removal of the probe’s casing may expose you to electric shock. If 

necessary, disconnect the inputs and outputs of the probe before opening 

the case.

Hazardous Contact

To avoid injury, remove jewelry such as rings, watches, and other metallic 

objects. Do not touch exposed connections and components when power 

is present.

Unexpected Charges

Hazardous voltages may be present in unexpected locations in circuitry 

being tested when a fault condition in the circuit exists.  

 

Содержание CT4192

Страница 1: ...CT4192 User Manual...

Страница 2: ...ne Do not work alone when working with high voltages Inspect the Probe Inspect the probe and accessories for cracks and frayed or broken leads before each use If defects or damages are noted DO NOT US...

Страница 3: ...r Not for Critical Applications This probe is not authorized for use in contact with the human body or for use as a component in a life support device or system Do Not Substitute Parts Do not install...

Страница 4: ...ainst any unintended operation Compliance Statements Disposal of Old Electrical Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This...

Страница 5: ...3dB z z Up to 700 V DC AC peak common mode z z Selectable attenuation settings of 10x 100x z z Power indicator z z High accuracy 1 z z Powered by 4 AA batteries included z z Power adapter CT3723 optio...

Страница 6: ...erview CT 4192 Description CT4192 1 M Hook probes black and red Attenuation Function Switch Output BNC Connector Power On Off Switch Power Indicator Red Offset Adjust External Power Connection Figure...

Страница 7: ...teries being sure to match polarity with the printed indicators inside the compartment Then Slide the cover back and replace the rubber boot See Figure 2 AA AA AA AA Figure 2 Battery Connection Altern...

Страница 8: ...V switch the attenuation ratio to 10x in order to get higher resolution and less noise ratio For voltages up to 700 V set the attenuation ratio to 100x 4 Plug the hook probes onto the test leads and c...

Страница 9: ...5 50 V div These values apply when the oscilloscope is set to the typical 1 M impedance input When the scope is set to 50 input the actual vertical scale will be doubled 10 V div for the 10x setting...

Страница 10: ...Default Setup and Auto on the oscilloscope 5 Press the Channel 1 button then press the probe softkey and set the attenuation to match that of the probe 6 Set the oscilloscope to DC coupled mode and t...

Страница 11: ...ntial Input Voltage DC AC peak 70 V 10x 700 V 100x Maximum Common Mode Input Voltage DC AC peak 70 V 10x 700 V 100x Absolute Max Rated Input Voltage each side to ground 1000 Vrms Input Resistance Capa...

Страница 12: ...de Operating 3 000 m Nonoperating 15 300 m Safety Specifications IEC 61010 031 CAT II Mechanical Characteristics Weight 400 g with probe and rubber boot Dimensions 170 x 63 x 21 mm BNC Cable Length 95...

Страница 13: ...Derating Curve The derating curve of the absolute maximum input voltage in common mode is shown as follows 1 000 10 000 100 10 1 10 100 Frequency MHz Volgage Vrms CT4192 Maximum Input Voltage Deratin...

Страница 14: ...persons will not be covered by this warranty Cal Test Electronics reserves the right to discontinue models change specifications price or design of this device at any time without notice and without...

Страница 15: ...450866 001 Rev B caltestelectronics com 14 Notes...