background image

450866-001 Rev. B                                      caltestelectronics.com                                                            13

7  Service & Warranty Information

Limited One-Year Warranty

Cal Test Electronics warrants this product to be free from defective 

material or workmanship for a period of 1 year from the date of original 

purchase. Under this warranty, Cal Test Electronics is limited to 

repairing the defective device when returned to the factory, shipping 

charges prepaid, within the warranty period. 
Units returned to Cal Test Electronics that have been subject to abuse, 

misuse, damage, or accident, or have been connected, installed, or 

adjusted contrary to the instructions furnished by Cal Test Electronics, 

or that have been repaired by unauthorized persons, will not be 

covered by this warranty. 
Cal Test Electronics reserves the right to discontinue models, change 

specifications, price, or design of this device at any time without notice 

and without incurring any obligation whatsoever. 
The purchaser agrees to assume all liabilities for any damages and/or 

bodily injury which may result from the use or misuse of this device by 

the purchaser, his employees, or agents. 
This warranty is in lieu of all other representations or warranties 

expressed or implied and no agent or representative of Cal Test 

Electronics is authorized to assume any other obligation in connection 

with the sale and purchase of this device. 

Service

If you have a need for calibration or repair services, technical, or sales 

support, please contact us: 

22820 Savi Ranch Parkway

Yorba Linda, CA 92887

800-572-1028 or 714-221-9330

caltestelectronics.com

Содержание CT4192

Страница 1: ...CT4192 User Manual...

Страница 2: ...ne Do not work alone when working with high voltages Inspect the Probe Inspect the probe and accessories for cracks and frayed or broken leads before each use If defects or damages are noted DO NOT US...

Страница 3: ...r Not for Critical Applications This probe is not authorized for use in contact with the human body or for use as a component in a life support device or system Do Not Substitute Parts Do not install...

Страница 4: ...ainst any unintended operation Compliance Statements Disposal of Old Electrical Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This...

Страница 5: ...3dB z z Up to 700 V DC AC peak common mode z z Selectable attenuation settings of 10x 100x z z Power indicator z z High accuracy 1 z z Powered by 4 AA batteries included z z Power adapter CT3723 optio...

Страница 6: ...erview CT 4192 Description CT4192 1 M Hook probes black and red Attenuation Function Switch Output BNC Connector Power On Off Switch Power Indicator Red Offset Adjust External Power Connection Figure...

Страница 7: ...teries being sure to match polarity with the printed indicators inside the compartment Then Slide the cover back and replace the rubber boot See Figure 2 AA AA AA AA Figure 2 Battery Connection Altern...

Страница 8: ...V switch the attenuation ratio to 10x in order to get higher resolution and less noise ratio For voltages up to 700 V set the attenuation ratio to 100x 4 Plug the hook probes onto the test leads and c...

Страница 9: ...5 50 V div These values apply when the oscilloscope is set to the typical 1 M impedance input When the scope is set to 50 input the actual vertical scale will be doubled 10 V div for the 10x setting...

Страница 10: ...Default Setup and Auto on the oscilloscope 5 Press the Channel 1 button then press the probe softkey and set the attenuation to match that of the probe 6 Set the oscilloscope to DC coupled mode and t...

Страница 11: ...ntial Input Voltage DC AC peak 70 V 10x 700 V 100x Maximum Common Mode Input Voltage DC AC peak 70 V 10x 700 V 100x Absolute Max Rated Input Voltage each side to ground 1000 Vrms Input Resistance Capa...

Страница 12: ...de Operating 3 000 m Nonoperating 15 300 m Safety Specifications IEC 61010 031 CAT II Mechanical Characteristics Weight 400 g with probe and rubber boot Dimensions 170 x 63 x 21 mm BNC Cable Length 95...

Страница 13: ...Derating Curve The derating curve of the absolute maximum input voltage in common mode is shown as follows 1 000 10 000 100 10 1 10 100 Frequency MHz Volgage Vrms CT4192 Maximum Input Voltage Deratin...

Страница 14: ...persons will not be covered by this warranty Cal Test Electronics reserves the right to discontinue models change specifications price or design of this device at any time without notice and without...

Страница 15: ...450866 001 Rev B caltestelectronics com 14 Notes...

Страница 16: ...2017 Cal Test Electronics 450866 001 Rev B...

Отзывы: