Safety Summary

WARNING

 

CAUTION

To avoid personal injury and/or product damage,

 review and comply 

with the following safety precautions. These precautions apply to both 

operating and maintenance personnel and must be followed during all 

phases of operation, service, and repair of this instrument.

Only qualified personnel should use this probe.

 This high voltage 

probe is designed to be used by personnel who are trained, experienced, 

or otherwise qualified to recognize hazardous situations and who are 

trained in the safety precautions necessary to avoid possible injury when 

using such a device. 

This instrument is intended for usage within Measurement Category I 

(CAT I) only. 
Do not work alone

 when working with high voltages.

Do not apply to the input any potential that exceeds the maximum 

rating of the probe.
For your own safety, inspect the probes

 for cracks and frayed or broken 

leads before each use. If defects are noted, DO NOT USE the probe.

Hands, shoes, floor and work bench must be dry. 
Avoid making measurements under humidity,

 dampness or other 

environmental conditions that might affect safety.

Turn the high voltage source off before connecting or disconnecting

 

the probe whenever possible.

The probe body should be kept clean

 and free of any conductive 

contamination.

Do not remove the probe casing.

 Removal of the probe’s casing may 

expose you to electric shock.

Keep fingers behind the probe’s finger guard

 during use.

Always properly ground the probe

 with the lead before contacting high 

voltage circuits with the probe tip. Always disconnect the probe tip from 

Содержание CT4026

Страница 1: ...CT4026 User Manual...

Страница 2: ...T I only Do not work alone when working with high voltages Do not apply to the input any potential that exceeds the maximum rating of the probe For your own safety inspect the probes for cracks and fr...

Страница 3: ...indoor Pollution Degree 2 environment Measurements made by this instrument may be outside specifications if the instrument is used in non office type environments Such environments may include rapid...

Страница 4: ...irective 2012 19 EU of the European Parliament and the Council of the European Union on waste electrical and electronic equipment WEEE and in jurisdictions adopting that Directive is marked as being p...

Страница 5: ...26 is an 18 kV High Voltage divider probe for use with both digital and analog oscilloscopes Features z Measures up to 18 kV DC ACpk or 12 kVrms AC z DC to 150 MHz bandwidth z Voltage dividing of 1000...

Страница 6: ...uation ratio setting to 100 1 3 WARNING If possible always turn the high voltage source off before connecting or disconnecting the probe 4 WARNING Connect the probe grounding lead via alligator clip t...

Страница 7: ...curacy of the waveform being measured by matching the probe to the oscilloscope s input capacitance Compensation should be adjusted whenever the probe is connected to or transferred between oscillosco...

Страница 8: ...ic cover to access these trimmers 5 Change the square wave output to 200 kHz or to the frequency you will be using in your testing 6 Turn the 200 kHz Trimmer for a flat topped square wave Figures 2 4...

Страница 9: ...800 572 1028 caltestelectronics com 4 Figure 4 shows a perfectly compensated probe Figure 4 Good Compensation...

Страница 10: ...Resistance 200 M Input Capacitance 1 5 pF Rise Time 2 4 ns Signal Noise 60 dB 1 KHz 50 dB 1 MHz Accuracy DC Volts 3 Accuracy AC Volts 3 at 1 kHz Cable Length 6 6 ft 2 m Designed for Use in Pollution D...

Страница 11: ...be sure to comply with the Voltage vs Frequency Derating Curve Figure 5 Voltage Derating Curve 6 Cleaning Clean only the exterior probe body and cables Use a soft cotton cloth lightly moistened with a...

Страница 12: ...been subject to abuse misuse damage or accident or have been connected installed or adjusted contrary to the instructions furnished by Cal Test Electronics or that have been repaired by unauthorized p...

Страница 13: ...800 572 1028 caltestelectronics com 8 Notes...

Страница 14: ...800 572 1028 caltestelectronics com 9 Notes...

Страница 15: ...800 572 1028 caltestelectronics com 10 Notes...

Страница 16: ...2018 Cal Test Electronics 450893 001 Rev A...

Отзывы: