background image

CALREC 

Putting Sound in the Picture

 

7

AfterSalesModifications

Please be aware that any modifications 
other than those made or approved by 
Calrec Audio Limited or their agents, may 
invalidate the console’s warranty.  This 
includes changes to cabling provided by 
Calrec and variations to the recommended 
installation as detailed in Calrec 
documentation.

Modifications to this equipment by any 
party other than Calrec Audio Limited 
may invalidate EMC and safety features 
designed into the equipment.  Calrec 
Audio Limited can not be liable for any 
legal proceedings or problems that may 
arise relating to such modifications. 

If in doubt, please contact Calrec Audio 
Limited for guidance prior to commencing 
any modification work.

Installation

In many installations the AC power 
connectors will not be readily accessible, 
effectively making the equipment 
permanently connected.  The installation 
should be carried out in accordance with all 
applicable installation rules and regulations.

ServicePersonnel

The AC power disconnect devices are 
the 2 x IEC (IEC60320-1 C13/C14) 
couplers located at the rear of each unit. 
WARNING: The apparatus has a dual 
power system.  It is essential that BOTH 
AC power IEC couplers are disconnected 
to prevent exposure to hazardous voltage 
within the unit.

ThirdPartyEquipment

Integrating third party equipment into 
a Calrec system may compromise the 
product’s ability to comply with the  
radiated emission limits set in the EMC 
(Electro Magnetic Compatibility) standard 
EN55022. 

Calrec Audio Limited can not be 
responsible for any non-conformities 
due to use of third party equipment.  If 
in doubt, please contact Calrec Audio 
Limited for guidance prior to integrating 
any third party equipment.

ESD(Static)HandlingProcedures

In its completed form, this equipment has 
been designed to have a high level of 
immunity to static discharges.  However, 
when handling individual boards and 
modules, many highly static sensitive 
parts are exposed. In order to protect 
these devices from damage and to protect 
your warranty, please observe static 
handling procedures, for example, use an 
appropriately grounded anti-static wrist 
band.  Calrec will supply an electrostatic 
cord and wrist strap with all of its digital 
products. 

All modules and cards should be returned 
to Calrec Audio Limited in anti-static 
wrapping.  Calrec Audio Limited can 
supply anti-static wrapping upon request. 

This applies particularly to digital products 
due to the types of devices and very 
small geometries used in their fabrication, 
analogue parts can, however, still be 
affected.

RoHSLegislation

In order to comply with European RoHS 
(Reduction of Hazardous Substances) 
legislation,  Calrec PCB and cable 
assemblies are produced with lead-free 
(tin/copper/silver) solder instead of tin/
lead solder.

In the unlikely event of a customer 
having to carry out any re-soldering on 
Apollo, Artemis or Hydra2 hardware, 
it is imperative that lead-free solder is 
used; contaminating lead-free solder with 

UKAS AND RAB REGISTRATION

LEAD FREE STICKER

LEAD FREE

leaded solder is likely to have an adverse 
effect on the long-term reliability of the 
product.  Circuit boards assembled with 
lead-free solder can be identified (in 
accordance with IPC/JEDEC standards) 
by a small oval logo (see below) on the 
top-side of the circuit board near the PCB 
reference number (8xx-xxx).  The same 
logo is used on the connector hoods of 
soldered cable assemblies. 

If in doubt, please check with a Calrec 
customer support engineer before 
carrying out any form of re-soldering

ISO9001andRABRegistered

Calrec Audio Ltd has been issued 
the ISO9001: 2008 standard by the 
Governing Board of ISOQAR.

The award, for both UKAS and RAB 
registration (see below), is the most 
comprehensive of the ISO9000 
international standards.  Granted in 
recognition of excellence across design, 
development, manufacture and after-
sales support, the certification follows a 
rigorous and thorough review of Calrec’s 
internal and external communication and 
business procedures.

Содержание SUMMA

Страница 1: ...calrec com Putting Sound in the Picture Networked Audio Production System SUMMA INSTALLATION MANUAL...

Страница 2: ...r International usage Calrec Audio Ltd reserve the right to change specifications without notice E O E The established policy of Calrec Audio Ltd is to seek improvements to the design specifications a...

Страница 3: ...types Layout 39 Connections 39 Card layout 39 Installing removing cards 39 Redundancy 39 Reset sync interface card 40 Standard status LEDs 40 Control Processor Module 40 DSP 41 Router 41 Power supply...

Страница 4: ...on and redundancy 66 Connection configuration 66 SW P 08 I O mapping configuration 66 Ember Remote Control 67 Remote Control Calrec Serial Control Protocol 68 CSCP versions 68 Faders controlled by CSC...

Страница 5: ...calrec com Putting Sound in the Picture SUMMA INFORMATION...

Страница 6: ...r and for assistance with exportation documents Standard of Service Ensuring the highest standards is a priority if you have any comments on the level of service product quality or documentation offer...

Страница 7: ...ards and modules many highly static sensitive parts are exposed In order to protect these devices from damage and to protect your warranty please observe static handling procedures for example use an...

Страница 8: ...with the dust cover fitted Cleaning For cleaning the front panels of the equipment we recommend using a soft anti static cloth lightly dampened with water if required Explanation of Warning Symbols T...

Страница 9: ...umma Core Power Router Control Processor and DSP redundancy is optional for a Summa with 128 channels and is provided as standard for a Summa with 180 channels SFPs One of the following four options L...

Страница 10: ...10 SUMMA Networked Audio Production System...

Страница 11: ...calrec com Putting Sound in the Picture SUMMA GETTING STARTED...

Страница 12: ...Control Processor Talkback Microphone Output Headphone Inputs Left Right 1 2 1 2 For more information on fibre and different connection types please see Connection Information on page 45 The two contr...

Страница 13: ...CALREC Putting Sound in the Picture 13 SUMMA CONSOLE TO CORE CONNECTIONS 2...

Страница 14: ...e the I O box from the console s required list see Summa User Manual 4 Remove the I O box from Hydra database in H2O I O box and port labels tab 5 Remove Shows memories patches which reference the I O...

Страница 15: ...ighbour making the 8th most significant bit equate to a decimal value of 128 All fixed format I O box ID switches are orientated the same way though some boxes such as MADI units use a different style...

Страница 16: ...er to the Calrec labelling printed on the circuit board around the switch to clarify its orientation When viewing the card from the side the most significant bit is on the left and the least significa...

Страница 17: ...orrect SFP for your connection type For a redundant system two connections are required primary and secondary In the diagram below the primary connection is the solid line and the secondary connection...

Страница 18: ...18 SUMMA Networked Audio Production System Getting Started CONNECTING FIXED FORMAT I O TO THE CORE Note The connections to the Pre 2015 core and 2015 core are the same...

Страница 19: ...connections While Calrec hardware can be run off one power connection it is advised for redundancy that you connect a separate power source to the primary and secondary power inlets In the following...

Страница 20: ...ostic tools for interacting with the Summa system and the wider Hydra2 network The laptop has one gigabit ethernet port which should be connected to the Surface 2 MAC 6 on some models connection on th...

Страница 21: ...e stamped making them easier to identify When you first start up your summa system it is important to set the current date and time To do this Tap SYSTEM SETTINGS in the top right hand corner of the t...

Страница 22: ...be connected to one of the USB ports on the front of the control processor to serve the same purpose Tap SYSTEM SETTINGS in the top right of the screen and select LAN CONFIGURATION from the left hand...

Страница 23: ...cking and reprogramming This will allow hardware to be replaced with off the shelf spares or with hardware from other systems without requiring manual configuration and reprogramming FIGURE 1 SYSTEM S...

Страница 24: ...ng out system wide software upgrades users should choose to back up the user data as a precaution via the Software Updater application Should a system lose user data e g a controller card failure in a...

Страница 25: ...calrec com Putting Sound in the Picture SUMMA CONTROL SURFACE...

Страница 26: ...multi function control cells and permanent metering for all faders within the 12 fader sections All Summa surfaces also have an additional 8 fader section The following diagrams show the different su...

Страница 27: ...CALREC Putting Sound in the Picture 27 12 8 FADER TOP VIEW 24 8 FADER TOP VIEW 875 50 mm 34 47 1308 0 mm 51 5...

Страница 28: ...28 SUMMA Networked Audio Production System Control Surface 36 FADER TOP VIEW WIDTH 1740 5 mm 68 5...

Страница 29: ...6137 Connection to 8 Fader Section CPU J1 USB and Reset Board RI6147 Connection to 8 Fader Section CPU J4 USB 2 USB 3 USB 1 Mic Preamp O P J6 I P J5 Status LED Reset Located on surface Talkback Microp...

Страница 30: ...5 0 5 10 20 30 40 50 60 10 5 0 5 10 20 30 40 50 60 User Buttons Layers 10 5 0 5 10 20 30 40 50 60 10 5 0 5 10 20 30 40 50 60 10 5 0 5 10 20 30 40 50 60 10 5 0 5 10 20 30 40 50 60 10 5 0 5 10 20 30 40...

Страница 31: ...ed for when deciding on the number and placement of Hydra2 I O boxes during the ordering process Talkback Mic and Headphone Connections Summa s built in talkback microphone is situated close to the Su...

Страница 32: ...32 SUMMA Networked Audio Production System Control Surface FRONT PANEL CONNECTIONS Headphone Output...

Страница 33: ...power inlet is a SAMTEC MPSC plug and the surface PSU connects via a SAMTEC MPSC socket A single latch locks the surface PSU in place and a large handle provides an easy way to support it during conn...

Страница 34: ...This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept interference reci...

Страница 35: ...full set of CUT and ON button caps CUT BUTTON Summa has a bank of 12 User Buttons which can be assigned using the GPIO system to control external devices See GPIO in the User Manual for more informati...

Страница 36: ...36 SUMMA Networked Audio Production System...

Страница 37: ...calrec com Putting Sound in the Picture SUMMA PROCESSING CORE...

Страница 38: ...ensure air can flow through the card frame No clearance is required above or below the core for cooling Support The weight at the rear of the core should be adequately supported to prevent stress on...

Страница 39: ...essing modules The first and last slots are for power supplies a PSU in either slot can power a fully populated core Two PSU s are fitted and the load shared to provide redundancy FRONT VIEW POPULATED...

Страница 40: ...urface 2 ports are only used for very large consoles with a second pair of surface switches or for sidecars containing their own surface switches Any of the 3 LAN ports can be used for CSCP mixer remo...

Страница 41: ...hot spare router module The Summa router card has 8 SFP ports that can be fitted with copper or fibre SFP s to allow connection of Hydra2 I O boxes and connections to other consoles or standalone Hydr...

Страница 42: ...th copper or fibre SFPs and are the data connection point for the control surface The left hand MAC7 port of the left hand primary control processor card connects to the primary surface switch within...

Страница 43: ...unobstructed to ensure air can flow through the card frame No clearance is required above or below the core for cooling Support The weight at the rear of the core should be adequately supported to pr...

Страница 44: ...gurable by the customer so any value with the exception of the values listed below can be selected Logically multiple consoles owned by the same customer should have the same customer ID but again thi...

Страница 45: ...calrec com Putting Sound in the Picture SUMMA CONNECTION INFORMATION...

Страница 46: ...numbered router ports right hand column Likewise for fixed format I O boxes the primary SFP module is the opposite way around to the secondary SFP module The modules are orientated so that the releas...

Страница 47: ...The SFP module will then be free to be removed SFP slot covers Dust covers should be fitted to all SFP slots that do not have SFP modules fitted in them in order to maintain connection reliability Lo...

Страница 48: ...n seriously impair performance Cable manufacturers advise that kinked cables should be discarded and replaced as the damage caused cannot be addressed simply by straightening them out Cables should no...

Страница 49: ...rmance and reliability of high speed data cabling Certification level test equipment can give a simple pass fail response but in doing so will test various important factors as well as pin out Certifi...

Страница 50: ...ects and equipment location become more important SFP modules are available for both singlemode and multimode fibre types It is important to select the correct SFP for the type of fibre being used in...

Страница 51: ...er Budget Fibre Type Max Distance SX Multimode LC Duplex 7 5 dB 62 5 125 m 275 m 50 125 m 550 m LX Singlemode LC Duplex 8 dB 8 125 m 10 km LX Singlemode bi di LC Simplex 11 5 dB 9 125 m 10 km LH Singl...

Страница 52: ...resses to the core which can cause damage over time Avoid snagging on other cables or conduit which will cause excessive tensions when pulling and can cause kinks and excessive bends in the fibre When...

Страница 53: ...otective cover over the end of the cable to avoid re contamination or insert the fibre back into the previously cleaned receptacle for immediate use Additional Notes Do not tip the can of Clean Dry Ai...

Страница 54: ...k reference as other cores interruptions to both audio and data carried by routers can be caused This can lead to false error warnings and I O boxes going offline Therefore it is essential to consider...

Страница 55: ...the network configuration If the order that cards are fitted in a modular frame is important in your installation please discuss this with your Calrec project engineer prior to delivery If for any re...

Страница 56: ...ction Information FIXED FORMAT MADI HYDRA2 I O REAR INTERFACE Connect from Primary Router card Connect from Secondary Router card MODULAR HYDRA2 I O CONTROLLER CARD FRONT INTERFACE Connect from Primar...

Страница 57: ...CALREC Putting Sound in the Picture 57 PROCESSING 2015 CORE ROUTER I O PORTS FOR CONNECTING TO I O BOXES Primary I O Ports Secondary I O Ports...

Страница 58: ...tween different manufacturers hardware GPO outputs The fixed format I O box GPIO card and the WY5858 modular GPIO card both have 8 changeover relays each with access to the normally open normally clos...

Страница 59: ...Normally Made 11 Relay 8 Common 24 Normally Open 12 Normally Made 25 Ground 13 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 25 Pin Female D Type Wiring side of connecting cable 1 C...

Страница 60: ...40 GPO 2 NO 24 NO 8 NC 41 NC 25 GPO 3 NO 9 NO 42 NC 26 NC 10 GPO 4 NO 43 NO 27 NC 11 NC 44 GPO 5 NO 28 NO 12 NC 45 NC 29 GPO 6 NO 13 NO 46 NC 30 NC 14 GPO 7 NO 47 NO 31 NC 15 NC 48 GPO 8 NO 32 NO 16...

Страница 61: ...T Normally Open relay Calrec GPIO card NO NO Function Pin GPI 1 1 34 GPI 2 18 2 GPI 3 35 19 GPI 4 3 36 GPI 5 20 4 GPI 6 37 21 GPI 7 5 38 GPI 8 22 6 Supply 5V 17 Supply 0V 50 Function Pin GPO 1 NO 39 N...

Страница 62: ...els by adding additional links to form Trunk Links Trunk links should only be fitted if they have been configured Please contact Calrec Customer Support or your local representative for guidance on tr...

Страница 63: ...CALREC Putting Sound in the Picture 63 MAIN ROUTER PORTS AVAILABLE FOR ROUTER TO ROUTER CONNECTIONS Primary Router Ports Secondary Router Ports...

Страница 64: ...64 SUMMA Networked Audio Production System...

Страница 65: ...calrec com Putting Sound in the Picture SUMMA REMOTE CONTROL AND PRODUCTION AUTOMATION...

Страница 66: ...continue SW P 08 communications via the connection made to the primary card s front panel If supported by the 3rd party controller a secondary connection can also be made to the secondary router card...

Страница 67: ...ty controller a secondary connection can also be made to the secondary router card in the same core providing additional redundancy against cable port and external third party switch controller failur...

Страница 68: ...ut buses all 16 for Summa Control over and read back of the first 20 Aux bus output levels all 16 for Summa Read back of the path types allocated to the 192 faders CSCP V2 1 provides all the functiona...

Страница 69: ...CALREC Putting Sound in the Picture 69 PORTS AVAILABLE FOR CSCP CONNECTIONS Primary Calrec Controller Ports Secondary Calrec Controller Ports...

Страница 70: ...ssing core and can be confirmed by running the Program Updater GUI on the support laptop If the default addresses are not suitable please supply alternative IP addresses and a subnet mask which can be...

Страница 71: ...rollers can route the normally active port to the Calrec primary card and the backup to the secondary For 3rd party controllers that operate on RS422 Calrec can also supply in line RS232 422 cable con...

Страница 72: ...configuration screen Select the COM port to which you have connected the Perle unit the default is COM 1 Also under the Configuration Destination menu select Serial Enter the port settings in the rele...

Страница 73: ...e subnet mask for each port can be changed and also the IP addresses themselves can be changed Click APPLY if any changes are made Note Web Manager page changes can be slow and do not always fully dis...

Страница 74: ...ion System Remote Control and Production Automation PERLE WEB MANAGER NETWORK IP ADDRESS PAGE PERLE WEB MANAGER NETWORK ADVANCED PAGE 192 168 1 10 192 168 2 10 192 168 1 10 255 255 0 0 255 255 0 0 192...

Страница 75: ...CALREC Putting Sound in the Picture 75 PERLE WEB MANAGER SERIAL SERIAL PORT PAGE PERLE WEB MANAGER SERIAL SERIAL PORT PORT 1 GENERAL PAGE 192 168 1 10 192 168 1 10 192 168 1 10...

Страница 76: ...76 SUMMA Networked Audio Production System PERLE WEB MANAGER SERIAL SERIAL PORT PORT 1 HARDWARE PAGE ADDITIONAL HOSTS 192 168 1 10...

Страница 77: ...calrec com Putting Sound in the Picture SUMMA SETUP USER LOGGING...

Страница 78: ...is 1 second if commented out missing or too low it will default to 1 sec Note that this also affects the refresh period of the shaft and fader level logging so if you want more resolution on fader mov...

Страница 79: ...e F Input RB Input LB Input Leg Routing LBRB Input MS Input Patch disabled Input Select Input Tone Input Trim Input Trim Link Master Input Gain Master Nudge Input Gain Master Input Phantom Power Maste...

Страница 80: ...n Listen Dyn Automix Link Select F Dyn Automix Weight F Dyn Comp Attack F Dyn Comp Knee F Dyn Comp Ratio Fine F Dyn Comp Ratio F Dyn Comp Recovery F Dyn Comp DSP Threshold U F Dyn Comp Threshold F Dyn...

Страница 81: ...s are saved as txt files and has a naming convention that allows easy sorting of oldest to newest e g if started at 30th September 2015 at 15 14 39 then this becomes 150930_151439_UserControlLog txt O...

Страница 82: ...82 SUMMA Networked Audio Production System...

Страница 83: ...calrec com Putting Sound in the Picture SUMMA SPECIFICATIONS...

Страница 84: ...dio Sub Groups 8 mono stereo or 5 1 Track Outputs 32 mono or stereo Aux Outputs 16 mono or stereo Direct Outputs 1 per Channel Mix Minus Outputs 1 per Channel Insert Sends Returns 1 per Channel Group...

Страница 85: ...ss 108 W 109 W 109 W Power Dissipation Heat Dark Mode 69 W 70 W 70 W Cooling The control surface is cooled by natural air convection The air intake is on the underside of the console and the outtake i...

Страница 86: ...sipation Heat Maximum Brightness 208 W 210 W 210 W Power Dissipation Heat Dark Mode 115 W 116 W 116 W Cooling The control surface is cooled by natural air convection The air intake is on the underside...

Страница 87: ...W Cooling The core is cooled by fan assisted convection Fan speed is monitored and system status warnings are generated if any fan slows or stops The Summa Core is fitted with 9 x 40mm low power low s...

Страница 88: ...Heat Output and Efficiency The Heat output from fixed format Hydra2 I O units depends on the supply voltage and loading Typically it is 0 55 times the RMS VA Volts x Amperes at 230V and 0 7 times the...

Страница 89: ...ls on modular I O Heat Output and Efficiency The Heat output from modular Hydra2 I O units depends upon the quantity and card types fitted please refer to the Hydra2 installation manual for more detai...

Страница 90: ...to 100kHz SRC THD N 117dB 1kHz 0 00014 Format AES EBU AES3 24 bit Interface 110 Ohm balanced XLR or D Type Jitter 0 015UI 2 5ns peak Analogue Digital Conversion 24 Bit Input Electronically Balanced I...

Страница 91: ...to 20kHz 0 5dB 48KHz Synchronization NTSC PAL Video Tri Level Internal Crystal Reference TTL Wordclock 48kHz AES EBU AES3 Digital Input 48kHz LATENCY 48KHZ SAMPLE RATE From To Via Samples ms AES3 inpu...

Страница 92: ...NCED DIGITAL INPUTS MODULAR I O ONLY system set for SRC on I P SRC on I P to Digital Outputs with 0 dB gain N A off 138 dB on 130 dB to Analogue Outputs with 0 dB gain 18 dBu 0 dBFS off 111 dB on 111...

Страница 93: ...N A HYDRA2 AES3 BALANCED DIGITAL OUTPUTS MODULAR I O ONLY system set for SRC on I P SRC on I P from Digital Inputs with 0 dB gain N A off 138 dB on 130 dB from Analogue Inputs with 0 dB gain 18 dBu 0...

Страница 94: ...IM6215 8 Fader Panel P G IM6158 Monitor Panel ML6157 Touchscreen MU6170 8 Fader Section CPU UN6143 Power Surface PSU ZN6163 Power Distribution Board ZN6142 Headphone and Talkback Board Circuit Board P...

Страница 95: ...704 087 ON Button Cap 704 079 Key Mat IM6158 L 704 081 Key Mat IM6158 R 704 082 User Button Cap 704 084 Key Mat CA6161 Fader Upper 704 080 Rotary Controller with push switch 230 795 Rotary Controller...

Страница 96: ...926 192 Iss 9 Calrec Audio Ltd Nutclough Mill Hebden Bridge West Yorkshire England UK HX7 8EZ Tel 44 0 1422 842159 Fax 44 0 1422 845244 Email Enquiries calrec com calrec com...

Отзывы: