Never use the electric power cable to

suspend the pump.

Attach the power supply cable to the delivery pipe

or to the safety rope with cable clamps. The

power cable should not be taut: allow for a certain

degree of slackness to avoid the risk of strain

caused by expansion of the pipe during

operation. 

3.3. Fixed installation with automatic

coupling feet and guide rails.

The automatic coupling system allows for quick

and efficient inspection operations.

The coupling foot is fastened to the bottom of the

sump together with the delivery pipe; two guiding

tubes connect it to the anchoring bracket secured

to the edge of the sump cover.

The pump is lowered along the guiding tubes until

it reaches the exact coupling position; the seal

will be tight thanks to the weight of the pump.

This operation can be repeated any number of

times and it makes checking and inspection

operations easier; the pump is simply extracted

from the sump by means of a chain (even if the

system is flooded).

4. Electrical connection

Electrical connection must be carried

out only by a qualified electrician in

accordance with local regulations.

Follow all safety standards.

The unit must be always earthed, also with a

non-metallic delivery pipe.

Make sure the frequency and mains voltage

correspond with the name plate data.
For use in swimming pools (not when persons are

in the pool), garden ponds and similar places, a

residual current device

with I∆N not exceeding

30 mA must be installed in the supply circuit.
Install a 

device for disconnection from the

mains 

(switch) with a contact separation of at

least 3 mm on all poles.

When extension cables are used, make sure the

cable wires are of adequate size to avoid voltage

drops and that the connection stays dry.

4.1. Single-phase pumps GXCM, GXVM

Supplied with

incorporated thermal

protector, with

power cable type

H07 RN8-F, 4G1 mm

2

and with  float

switch.

Control box with

capacitor supplied

on request.

Electrical diagram

4.2. Single-phase pumps GMCM, GMVM

Supplied with incorporated capacitor and thermal

protector, with power cable type H07 RN8-F,

3G1.5 mm

2

with plug and float switch.

4.3. Three-phase pumps GXC, GXV

Install in the control box an overload-protective

device in accordance with the name-plate current.

4.4. Three-phase pumps GMC, GMV

Fitted with 2 thermal protectors which are connected

in series and inserted between two different phases.

The thermal protectors, in the three-phase motors,

provide protection against overloading and not

against operation with a blocked rotor.

The control box must therefore also be fitted with

a suitable hot-wire ammeter relay cuopled with

the control contactor.
Follow the electrical circuit diagram indicated below

With three-phase pumps, when the water level is

not under direct visible control, install a float

switch connected to the control box to protect the

pump against dry running and to set the water

levels to stop and automatically start the pump.

green/yellow

black

blue

maroon

grey

grey

Motor

3 ~ 220-240 V

3 ~ 380-415 V

To the terminal connection

points of the contactor

Thermal protectors

to connect  to the

contator coil

4.93.002/2

M

1

black 

grey (blue) 

maroon

green/yellow

4.

93

.0

02

/3