Caloric CVU306C-SS Скачать руководство пользователя страница 3

 

IMPORTANT SAFETY PRECAUTIONS 

READ AND SAVE THESE 

INSTRUCTIONS CAUTION 

For residential use only. Do not use to exhaust hazardous or explosive materials and/or vapors. 

 

CAUTION 

Range hood may have very sharp edges; please wear protective gloves when installing, cleaning 
or servicing the unit. 

This  appliance  must  be  installed  by  a  qualified  technician.  The  manufacturer  declines  all 
responsibility in case of failure to adhere to safety standards. Install this hood in accordance with 
all the specified requirements

 

WARNING 

To reduce the risk of fire, electric shock or injury to persons, observe the following: 

 

Use  this  unit only  in  the  manner  intended  by the manufacturer.  If  you  have  any  questions, 
contact the manufacturer.

 

 

Before servicing or cleaning the unit, switch power off at the service panel and lock the service 
disconnecting  means  to  prevent  power  from  being  switched  on  accidentally.  If  the  service 
disconnecting means cannot be locked, securely fasten a noticeable warning device, such as a 
tag, to the service panel.

 

 

Installation work and electrical wiring must be done by a qualified person in accordance with 
all applicable codes & standards, including Fire-rated construction.

 

 

Sufficient air is needed for proper combustion and exhausting of gases through the chimney 
(chimney) of fuel burning equipment to prevent back-drafting.

 

 

Follow the heating equipment 

manufacturer’s

 guideline  and safety standards such as those 

published by the 

National Fire Protection Association 

(NFPA) and the local code authorities.

 

 

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

 

 

Ducted fans must always be vented to the outdoors.

 

 

Do not make alterations to the original wiring.

 

 

Do not attempt to repair or replace any part of your hood unless it is specifically 
recommended in this manual.

 

 

All other servicing issue should be referred to a qualified technician

.

 

 

CAUTION: 

To reduce risk of fire and to properly exhaust air, be sure to duct air outside - do not vent exhaust air into 
spaces within such as walls, ceilings, attics, crawl spaces, or garages. 

Automatically operated device - to reduce risk of injury disconnect from power supply before servicing. 

Содержание CVU306C-SS

Страница 1: ...ON GUIDE USE AND CARE MANUAL Installer Leave this manual with the homeowner Homeowner Keep this guide for future reference Installateur Laissez ce manuel au propri taire Propri taire Conservez ce guid...

Страница 2: ...ALLATION OF THE UNIT MUST RESPECT ALL CODES IMPORTANT Keep these instructions in order to provide them to the electrical inspector in your area INSTALLER Please leave these instructions with the owner...

Страница 3: ...h as a tag to the service panel Installation work and electrical wiring must be done by a qualified person in accordance with all applicable codes standards including Fire rated construction Sufficien...

Страница 4: ...e of the cookingelement WARNING TO REDUCE THE RISK OF INJURY TO PERSONS INTHE EVENT OF A COOKTOP GREASE FIRE OBSERVE THE FOLLOWING Smother flames with a close fitting lid cookie sheet or metal tray an...

Страница 5: ...river Flathead screwdriver Adjustable wrench Utility knife Scissors to cut duct tape Aluminum duct tape Marker or pencil Level Measuring tape PARTS INCLUDED Baffle filters Top cover for square exhaust...

Страница 6: ...but is not guaranteed by us may be incomplete and or may change without notice A Floor to ceiling height variable B Floor to counter top height standard 36 C Recommended height between cooking surface...

Страница 7: ...he electrical supply does not meet above requirements call a licensed electrician before proceeding Route house wiring as close as possible to the installation location in the ceiling or back wall The...

Страница 8: ...be vented vertically through the roof through 6 15 3 cm round metal aluminum vent or vented horizontally through the wall through a rectangular vent measuring 3 x 10 The size of the vent should beuni...

Страница 9: ...wall To vent through a wall a 90 elbow may be needed This range hood is factory set for vertical venting using round or rectangular vent adapter but can be converted to horizontal venting by swapping...

Страница 10: ...on of the venting pipe from the hood to theoutside A straight short vent run will allow the hood to performmore efficiently Tryto avoid as many transitions elbows and long runs as possible This may re...

Страница 11: ...ABINET CUT OUT seen from the rear centerline Mounting screws Electrical Access Opening Rear duct access Wood filler support strips not included Top duct exhaust access Mounting screw attachment WALL E...

Страница 12: ...om the inside of the hood place hood mounting screws in the exact center of each knockout holes and secure to the cabinet bottom Tighten all screws until secure Be careful when using electrical screwd...

Страница 13: ...to enter timer mode Increase value button To increase blower speed to increase timer and to reset cumulative timer Clock DigitalDisplay button Todisplay current time when motor is OFF Shows current bl...

Страница 14: ...normal mode Power Off Delay Timer inactivated rapidly press the Power Control On Off button twice to turn off the blower motor Lights Press the Light button once to turn on the lights and once again t...

Страница 15: ...e filters are intended to filter out residue and grease from cooking and are required to be kept clean Filters should be cleaned after every 30 hours of use or once a month depending on use Remove and...

Страница 16: ...uses LED light fixture 3W Max 12VLED Make sure the range hood is unplugged or turn OFF the breaker Make sure the lights are cool to touch Placea flat head screwdriver betweenthe light housingand the...

Страница 17: ...repair center Damage resulting from accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with electrical codes or use of consumables or cleanin...

Страница 18: ...TOUS LES CODES LOCAUX NATIONAUX EN VIGUEUR IMPORTANT Conservez ces instructions afin de pouvoir les remettre l inspecteur lectricien de votre r gion INSTALLATEUR Veuillez laisser ces instructions ave...

Страница 19: ...ion et de raccordement lectriques doivent tre effectu s par une personne qualifi e conform ment aux codes et aux standards de construction incluant ceux concernant la protection contre les incendies L...

Страница 20: ...acuation Utilisez le bon format de casserole Servez vous toujours de casseroles et d ustensiles appropri s la dimension de la surface de cuisson AVERTISSEMENT AFIN D VITER TOUT RISQUE DE BLESSURES LOR...

Страница 21: ...ate Couteau tout usage Ciseaux pour couper du ruban pour conduit Ruban m tallique pour conduits Marqueur ou crayon Niveau Ruban mesurer PI CES INCLUSES Filtres chicanes Couvert pour vacuation rectangu...

Страница 22: ...r et ils peuvent par ailleurs tre incomplets et ou chang s sans pr avis A Hauteur du plancher au plafond Variable B Hauteur du plancher au comptoir habituellement standard 36 C Hauteur recommand e ent...

Страница 23: ...120V 60Hz fournie mais noninstall e S assurer que la hotte est correctement install e et mise laterre Si l alimentation lectrique ne r pond pas aux exigences consultez un lectricien avant de poursuiv...

Страница 24: ...n aluminium rond de 6 15 3 cm ou horizontalement travers le mur par un conduit de 3 x 10 La taille de l vent doit treuniforme Si vous ventilez vers le toit ne pas utiliser plus de trois coudes 90 Ne p...

Страница 25: ...e terminer que par le toit ou le mur seulement Pour vacuer travers un mur un coude 90 peut tren cessaire Cette hotte est con ue pour une vacuation verticale l aide d un adaptateur d vacuation rond ou...

Страница 26: ...s du dos et autres blessures Planifiez le circuit d vacuation vers l ext rieur Planifiez le parcours le plus court et le plus rectiligne possible et utilisez aussi peu de coudes que possible vitez d i...

Страница 27: ...DIAGRAMME DE LA D COUPE pour vacuation horizontale arri re Axe central Bandes de remplissage en bois non comprises Trou d acc s conduit du dessus Vis de montage MUR Ouverture pour acc s lectrique Vis...

Страница 28: ...centre exact de chaque trou de passage et fixez les au dessous de l armoire Serrez toutes les vis jusqu ce qu elles soient bien fix es Soyez prudent lorsque vous utilisez un tournevis lectrique afin d...

Страница 29: ...int Indique la vitesse actuelle du ventilateur moteur F1 F3 Lumi re Pour allumer teindre les lumi res DEL Contr les R glage de la vitesse du ventilateur Appuyez une fois sur le bouton Marche Arr t pou...

Страница 30: ...e en acier inoxydable Pour les d p ts de salet ou de graisse plus importants utilisez un liquide d graisseur Pour nettoyer la surface de la hotte utilisez un nettoyant pour acier inoxydable vitez tout...

Страница 31: ...uvelles lampes ne fonctionnent pas v rifiez que chaque lampe soit correctement ins r e dans sa douille avant de demander l intervention d un agent de service REMPLACEMENT DES LUMIERES AU DEL suite ATT...

Страница 32: ...limit e ne s applique pas en cas d une mauvaise installation d une mauvaise utilisation de n gligence d incendie ou autres causes ext rieures d alt rations r paration non conforme ou encore d un usag...

Страница 33: ...re de r paration agr Caloric abus incendie inondation catastrophe naturelle inappropri installation installation non conforme aux codes lectriques ou utilisation de consommables ou de produits de nett...

Отзывы: