Caloric CVU306C-SS Скачать руководство пользователя страница 26

 

INSTALLATION 
ÉLECTRIQUE 
AVERTISSEMENT 

LE  RACCORDEMENT  ÉLECTRIQUE  DOIT  ÊTRE  EFFECTUÉ  PAR  UN  PERSONNEL  QUALIFIÉ  EN  RESPECTANT  LES 
NORMES  ET  RÈGLEMENTS  EN  VIGUEUR.  CET  APPAREIL  DOIT  ÊTRE  RELIÉ  À  UNE  MISE  À  LA  TERRE.  AVANT 

D’EFFECTUER  LE  BRANCHEMENT,  COUPEZ  L’ALIMENTATION  ÉLECTRIQUE  DEPUIS  LA  BOÎTE  DE  CIRCUIT 

PRINCIPALE. 

UN MAUVAIS BRANCHEMENT PEUT ENTRAÎNER UN RISQUE D’ÉLECTROCUTION. CONSULTEZ UN ÉLECTRICIEN SI 

LES INSTRUCTIONS DE MISE À LA TERRE NE SONT PAS TOUT À FAIT COMPRISES OU SI UN DOUTE PERSISTE QUANT 

À SAVOIR SI L’APPAREIL EST CORRECTEMENT RELIÉ À LA TERRE. NE PAS UTILISER DE RALLONGE ÉLECTRIQUE. SI 
LE  CORDON  D’ALIMENTATION  EST  TROP  COURT,  DEMANDEZ  À  UN  ÉLECTRICIEN  D’INSTALLER  UNE  PRISE  DE 
COURANT PRÈS DE L’APPAREIL.

 

 

Cet appareil doit être relié à une prise correctement installée et mise à la terre. En cas de court-

circuit  électrique,  la  mise  à  la  terre  réduit  le  risque  d’électrocution  en  fournissant  un  câble 

d’évacuation pour le courant.

 

 

PRÉPARATION 

     

AVERTISSEMENT

 

Au moins deux personnes sont requises pour 

déplacer et installer cette hotte. S’il vous plaît 

suivre les in

structions afin d’éviter les blessures 

du dos et autres blessures.

 

 

 

Planifiez  le  circuit  d'évacuation  vers  l'extérieur.  Planifiez  le  parcours  le  plus  court  et  le  plus 

rectiligne possible et utilisez aussi peu de coudes que possible. Évitez d’installer un t

rop grand 

nombre de coudes et de transitions car cela réduira la performance de la hotte. Des conduits 

plus grands peuvent être nécessaires lors de l’installation d’une canalisation plus

 longue.

 

 

Pour installer sous le placard avec fond encastré, attachez de larges bandes de remplissage de 

bois de 4’’ (non fournies) de chaque côté. Voir Figure

 1.

 

 

En  utilisant  les  références  dans  les  mesures  et  schémas  d'installation,  créez  une  ouverture 
d'accès pour les fils électriques et l'évacuation de la hotte sous l'armoire.

 

ATTENTION  :  Si  vous  déplacez  LA  CUISINIÈRE  POUR  INSTALLER  LA  HOTTE  ;  COUPEZ  'ALIMENTATION

 

ÉLECTRIQUE  

DIRECTEMENT   À  LA  BOÎTE  DE  CIRCUIT  ÉLECTRIQUE   PRINCIPAL  OU   ENCORE ÉTEINDRE 

LE GAZ 

(s’il s’agit d’un appareil AU GAZ)

 

 

Figure 

Figure 

2

 

 

Percez les trous d'arrêt (pour le montage sous l'armoire) sur la hotte tel qu’illustré à la Figure

 2.

 

 

Si nécessaire, fixez deux supports en caoutchouc avec du ruban adhésif aux coins arrières de la hotte.

 

 

Risque de blessures sérieuses

 

Les palmes du ventilateur peuvent causer des 

blessures graves. Restez à l'écart du ventilateur 

lorsque le moteur tourne.

 

Содержание CVU306C-SS

Страница 1: ...ON GUIDE USE AND CARE MANUAL Installer Leave this manual with the homeowner Homeowner Keep this guide for future reference Installateur Laissez ce manuel au propri taire Propri taire Conservez ce guid...

Страница 2: ...ALLATION OF THE UNIT MUST RESPECT ALL CODES IMPORTANT Keep these instructions in order to provide them to the electrical inspector in your area INSTALLER Please leave these instructions with the owner...

Страница 3: ...h as a tag to the service panel Installation work and electrical wiring must be done by a qualified person in accordance with all applicable codes standards including Fire rated construction Sufficien...

Страница 4: ...e of the cookingelement WARNING TO REDUCE THE RISK OF INJURY TO PERSONS INTHE EVENT OF A COOKTOP GREASE FIRE OBSERVE THE FOLLOWING Smother flames with a close fitting lid cookie sheet or metal tray an...

Страница 5: ...river Flathead screwdriver Adjustable wrench Utility knife Scissors to cut duct tape Aluminum duct tape Marker or pencil Level Measuring tape PARTS INCLUDED Baffle filters Top cover for square exhaust...

Страница 6: ...but is not guaranteed by us may be incomplete and or may change without notice A Floor to ceiling height variable B Floor to counter top height standard 36 C Recommended height between cooking surface...

Страница 7: ...he electrical supply does not meet above requirements call a licensed electrician before proceeding Route house wiring as close as possible to the installation location in the ceiling or back wall The...

Страница 8: ...be vented vertically through the roof through 6 15 3 cm round metal aluminum vent or vented horizontally through the wall through a rectangular vent measuring 3 x 10 The size of the vent should beuni...

Страница 9: ...wall To vent through a wall a 90 elbow may be needed This range hood is factory set for vertical venting using round or rectangular vent adapter but can be converted to horizontal venting by swapping...

Страница 10: ...on of the venting pipe from the hood to theoutside A straight short vent run will allow the hood to performmore efficiently Tryto avoid as many transitions elbows and long runs as possible This may re...

Страница 11: ...ABINET CUT OUT seen from the rear centerline Mounting screws Electrical Access Opening Rear duct access Wood filler support strips not included Top duct exhaust access Mounting screw attachment WALL E...

Страница 12: ...om the inside of the hood place hood mounting screws in the exact center of each knockout holes and secure to the cabinet bottom Tighten all screws until secure Be careful when using electrical screwd...

Страница 13: ...to enter timer mode Increase value button To increase blower speed to increase timer and to reset cumulative timer Clock DigitalDisplay button Todisplay current time when motor is OFF Shows current bl...

Страница 14: ...normal mode Power Off Delay Timer inactivated rapidly press the Power Control On Off button twice to turn off the blower motor Lights Press the Light button once to turn on the lights and once again t...

Страница 15: ...e filters are intended to filter out residue and grease from cooking and are required to be kept clean Filters should be cleaned after every 30 hours of use or once a month depending on use Remove and...

Страница 16: ...uses LED light fixture 3W Max 12VLED Make sure the range hood is unplugged or turn OFF the breaker Make sure the lights are cool to touch Placea flat head screwdriver betweenthe light housingand the...

Страница 17: ...repair center Damage resulting from accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with electrical codes or use of consumables or cleanin...

Страница 18: ...TOUS LES CODES LOCAUX NATIONAUX EN VIGUEUR IMPORTANT Conservez ces instructions afin de pouvoir les remettre l inspecteur lectricien de votre r gion INSTALLATEUR Veuillez laisser ces instructions ave...

Страница 19: ...ion et de raccordement lectriques doivent tre effectu s par une personne qualifi e conform ment aux codes et aux standards de construction incluant ceux concernant la protection contre les incendies L...

Страница 20: ...acuation Utilisez le bon format de casserole Servez vous toujours de casseroles et d ustensiles appropri s la dimension de la surface de cuisson AVERTISSEMENT AFIN D VITER TOUT RISQUE DE BLESSURES LOR...

Страница 21: ...ate Couteau tout usage Ciseaux pour couper du ruban pour conduit Ruban m tallique pour conduits Marqueur ou crayon Niveau Ruban mesurer PI CES INCLUSES Filtres chicanes Couvert pour vacuation rectangu...

Страница 22: ...r et ils peuvent par ailleurs tre incomplets et ou chang s sans pr avis A Hauteur du plancher au plafond Variable B Hauteur du plancher au comptoir habituellement standard 36 C Hauteur recommand e ent...

Страница 23: ...120V 60Hz fournie mais noninstall e S assurer que la hotte est correctement install e et mise laterre Si l alimentation lectrique ne r pond pas aux exigences consultez un lectricien avant de poursuiv...

Страница 24: ...n aluminium rond de 6 15 3 cm ou horizontalement travers le mur par un conduit de 3 x 10 La taille de l vent doit treuniforme Si vous ventilez vers le toit ne pas utiliser plus de trois coudes 90 Ne p...

Страница 25: ...e terminer que par le toit ou le mur seulement Pour vacuer travers un mur un coude 90 peut tren cessaire Cette hotte est con ue pour une vacuation verticale l aide d un adaptateur d vacuation rond ou...

Страница 26: ...s du dos et autres blessures Planifiez le circuit d vacuation vers l ext rieur Planifiez le parcours le plus court et le plus rectiligne possible et utilisez aussi peu de coudes que possible vitez d i...

Страница 27: ...DIAGRAMME DE LA D COUPE pour vacuation horizontale arri re Axe central Bandes de remplissage en bois non comprises Trou d acc s conduit du dessus Vis de montage MUR Ouverture pour acc s lectrique Vis...

Страница 28: ...centre exact de chaque trou de passage et fixez les au dessous de l armoire Serrez toutes les vis jusqu ce qu elles soient bien fix es Soyez prudent lorsque vous utilisez un tournevis lectrique afin d...

Страница 29: ...int Indique la vitesse actuelle du ventilateur moteur F1 F3 Lumi re Pour allumer teindre les lumi res DEL Contr les R glage de la vitesse du ventilateur Appuyez une fois sur le bouton Marche Arr t pou...

Страница 30: ...e en acier inoxydable Pour les d p ts de salet ou de graisse plus importants utilisez un liquide d graisseur Pour nettoyer la surface de la hotte utilisez un nettoyant pour acier inoxydable vitez tout...

Страница 31: ...uvelles lampes ne fonctionnent pas v rifiez que chaque lampe soit correctement ins r e dans sa douille avant de demander l intervention d un agent de service REMPLACEMENT DES LUMIERES AU DEL suite ATT...

Страница 32: ...limit e ne s applique pas en cas d une mauvaise installation d une mauvaise utilisation de n gligence d incendie ou autres causes ext rieures d alt rations r paration non conforme ou encore d un usag...

Страница 33: ...re de r paration agr Caloric abus incendie inondation catastrophe naturelle inappropri installation installation non conforme aux codes lectriques ou utilisation de consommables ou de produits de nett...

Отзывы: