WARNING
PLEASE MAKE SURE NOT TO DO DAMAGE ELECTRICAL WIRING OR OTHER NON-APPARENT EQUIPMENT WHEN
CUTTING. WHEN CONSTRUCTING THE CARPENTRY, ALWAYS FOLLOW ALL APPLICABLE BUILDING CODES AND
STANDARDS.
WARNING
: AT LEAST TWO (2) PERSONS ARE NECESSARY TO LIFT AND POSITION THEHOOD.
WARNING
: BE CAREFUL WHEN INSTALLING THE HOOD AS IT MAYHAVESHARP EDGES.
WE RECOMMEND
THAT YOU WEAR PROTECTIVEGLOVES.
CAUTION
: DO NOT REMOVE THE PROTECTIVE PLASTIC FILM COVERING THE HOOD AT THISSTAGE.
LOCATION PREPARATION
•
It is recommended that the exhaust
system be
set up before the hood is installed.
•
Before cutting, make sure that the separation distances for the fittings in the walls and/or roof are adequate.
•
Before mounting the cabinet to the wall, cut the opening in the bottom of the cabinet beforehand.
1.
Disconnect the power source.
2.
Determine the method of discharge
to be
used: discharge through the wall or roof.
3.
Choose a flat surface for
the hood
assembly. Place the protective material on
this surface.
4.
Using two or more people, lift the hood over the
covered surface
.
PREPARING THE CUT-OUT
1.
Use a jigsaw or reciprocal saw to cut an opening in the bottom of the cabinet, inside the frame
.
NOTE
:
For frameless cupboards, a ¾" (1.9 cm) front and rear edge is required to form a frame in the bottom of
the cabinet. A ¾" (1.9 cm) thick support rod (not included) may be required for certain
types of
cabinets.
OPENING DIMENSIONS
3/4”
Model CVI28-SS
3/4”
A = Opening in the cupboard
3/4”
Model CVI34-SS
3/4”
16.5”
28”
16.5
’’
34
’’