14
Adjusting Air Shutter
1.
Remove 4 burner control knobs from range.
• Exposes 2 screws on burner control panel.
2.
Remove 2 screws from burner control panel.
• Panel drops slightly after screws are removed.
3.
Grasp bottom of burner control panel, gently lift and
pull out panel until clear of burner valve stems.
• After burner control panel clears valve stems,
continue to roll panel until free from range. Set
aside. See
Pivot Point in figure.
• Gas valve and orifice hood are visible after burner
control panel is removed.
A
B
C
D
A—Burner Control Knob
B—Pivot Point
C—Burner Control Panel
D—Screw
Burner Control Panel
4.
Slide air shutter open or closed depending on
appearance of burner flame.
• If flame is yellow and does not hold its shape, open
air shutter.
• If flame is blowing or noisy, close air shutter.
5.
Reassemble burner control panel.
Open
Close
Adjusting Air Shutter
Correct
Not centered
Too small
Too large
Burner Caps
Test and Adjust Surface Burner Flame
WARNING
!
To avoid electric shock that can cause personal injury
or death, disconnect main electrical supply to range
before servicing.
Turn on burner. See
Operating Surface Burners section
for burner operating instructions. Surface burner should
ignite within 4 seconds. Properly adjusted surface burner
flames are clean and blue with a distinct inner cone
approximately ¼ inch to ½ inch long. Some yellow flame
is normal when burning LP/Propane.
See Adjusting Air Shutter section,
• If burner flame is blowing or noisy, reduce airflow to
burner.
• If burner flame does not hold its shape, increase airflow
to burner.
A
Burner
A—¼ inch to ½ inch long
Surface Burner Flame
Burner Installation
(cont.)
Содержание CSG7601