
Troubleshooting
51
Use & Care Manual
I
F YOU CAN
’
T FIND AN ANSWER TO YOUR PROBLEM IN THE CHART BELOW
,
OR IF THE PROBLEM
CANNOT BE FIXED
,
YOU WILL NEED TECHNICAL HELP
. C
ONTACT YOUR
A
UTHORIZED
S
ERVICE
C
ENTER OR
C
USTOMER
C
ARE
.
P
ROBLEM
P
OSSIBLE CAUSES
W
HAT TO DO
C
OOKTOP
S
OME BURNERS WILL NOT LIGHT
.
F
LAMES DO NOT BURN ALL AROUND THE BURNER
CAP
.
B
URNER PARTS OR IGNITERS MAY BE
WET
,
DIRTY
,
OR MISALIGNED
.
C
HECK THAT THE BURNER PARTS ARE CLEAN
,
DRY
,
AND CORRECTLY ASSEMBLED
.
C
HECK THAT THE IGNITERS ARE CLEAN AND DRY
. S
EE
‘C
ARE AND CLEANING
’
FOR
INSTRUCTIONS
.
B
URNER FLAMES VERY LARGE AND YELLOW
.
B
URNER BEZEL PORTS ARE CLOGGED
. B
URNER PORTS OR BURNER CAPS ARE NOT
POSITIONED PROPERLY
. C
OOKTOP IS BEING OPERATED WITH THE WRONG TYPE
OF GAS
. R
EGULATOR IS NOT INSTALLED
,
IS FAULTY
,
OR IS SET FOR THE WRONG
TYPE OF GAS
.
C
LEAN BURNER BEZEL RING PORTS WITH STRAIGHTENED PAPER CLIP
,
NEEDLE
,
OR
WIRE
. R
EMOVE AND CAREFULLY RE
-
INSTALL BURNER BEZEL AND CAPS
. E
NSURE THAT
THE TYPE OF COOKTOP MATCHES THE NATURAL GAS SUPPLY
. C
HECK INSTALLATION
,
REPLACE REGULATOR
,
OR SET REGULATOR FOR PROPER GAS
.
S
PARKING BUT NO FLAME IGNITION
.
G
AS SHUT
-
OFF VALVE IS IN THE
‘OFF’
POSITION
.
T
URN SHUT
-
OFF VALVE TO THE
‘ON’
POSITION
.
I
GNITERS SPARK CONTINUOUSLY AFTER FLAME
IGNITION
.
P
OWER SUPPLY POLARITY IS REVERSED
. I
GNITERS ARE WET OR DIRTY
.
H
AVE POLARITY CORRECTED
. D
RY OR CLEAN IGNITERS
.
B
URNER FLAME GOES OUT AT LOW SETTING
.
L
OW GAS SUPPLY PRESSURE
. A
IR INTAKE HOLES AROUND KNOBS ARE
OBSTRUCTED
.
C
ONTACT GAS COMPANY
. R
EMOVE OBSTRUCTION
.
T
HE FLAMES HAVE
SUDDENLY GONE OUT
.
A
DRAFT OR A SPILL HAS EXTINGUISHED THE FLAME
.
N
O ACTION REQUIRED
. T
HE BURNER WILL DETECT THIS AND AUTOMATICALLY RELIGHT
.
H
OWEVER
,
IF THERE HAS BEEN A LARGE SPILL
,
WE RECOMMEND TURNING THE
BURNERS OFF AND CLEANING THE BURNERS AND SUMP AREA
. S
EE
CARE AND CLEANING FOR INSTRUCTIONS
.
T
HERE IS A POWER FAILURE
–
CAN
I
STILL USE THE
COOKTOP BURNERS
?
P
OWER OUTAGE IN YOUR AREA
.
T
HE COOKTOP BURNERS CAN STILL BE USED
. T
O LIGHT THEM
:
1. H
OLDING A LIGHTED MATCH TO THE FLAME SPREADER
,
PUSH IN ON THE CONTROL
KNOB AND TURN COUNTERCLOCKWISE TO
LITE.
2. W
HEN THE FLAME IS BURNING ALL THE WAY AROUND THE BURNER
,
YOU MAY
ADJUST THE HEAT
.
I
MPORTANT
!
I
F THE FLAME IS BLOWN OUT DURING A POWER FAILURE
,
TURN THE KNOB
IMMEDIATELY TO
OFF,
AS THE BURNER WILL NOT AUTOMATICALLY RELIGHT AND GAS
MAY ESCAPE
.
PLEASE VISIT US AT: WWW.CALORICAPPLIANCES.CA
Содержание CPR SERIES
Страница 2: ...2 Use Care Manual PLEASE VISIT US AT WWW CALORICAPPLIANCES CA Welcome...
Страница 13: ...Installation Introduction 13 Use Care Manual PLEASE VISIT US AT WWW CALORICAPPLIANCES CA...
Страница 17: ...Installation Introduction 17 Use Care Manual PLEASE VISIT US AT WWW CALORICAPPLIANCES CA...