VALEUR DISJONCTEUR
CIRCUIT
ELECTRIQUE
2.5A
VENTILATEUR 1 ET 2
COMPRESSEUR 1 ET 2
23.8A
1.7A
VOYANT
ALIMENTATION
L3
L2
L1
MONITEUR DE
PHA
SES
DISJONCTEUR
CIRCUIT ELECTRIQUE
6 (N/F
)
5
4 (N/F
)
3
2 (N/F
)
1
TEMPORISATION 1
(12 HEURES)
VOYANT
DEGIVRAGE
THERMOST
AT
DE GIVRA
GE
CIRCUIT 1
THERMOST
AT
DE GIVRA
GE
CIRCUIT 2
CIRCUIT 1
VO
YANT
DEF
A
UT
CIRCUIT 2
VO
YANT DEF
A
UT
CONT
A
CT DEF
A
UT
COMPRES
SUER 1
PRES
SOST
AT BP
(SE COUPE A H EN
BA
SSE PRES
SION
)
PRES
SOST
AT HP
CIRCUIT 1 FRIGORIFIQUE
(SE COUPE A L EN
HA
UTE PRES
SION
)
PRES
SOST
AT BP
(SE COUPE A H EN
BA
SSE PRES
SION
)
CONT
A
CT DEF
A
UT
COMPRES
SUER 2
PRES
SOST
AT HP
CIRCUIT 2 FRIGORIFIQUE
(SE COUPE A L EN
HA
UTE PRES
SION
)
COMP 1
RECHAUFFEUR COMP 1
ELECTROVANNE (ARRET
LIGNE LIQUIDE)
CIRCUIT 1
COMP 2
A1
A2
CONTACTEUR
VENTILATEUR 1
6 (N/O)
5
3
4 (N/O)
1
2 (N/O)
CONTACTEUR
COMP 2
22 (N/F)
64 (N/O)
63 (AUX)
VENTILATEUR 1
VENTILATEUR 2
RECHAUFFEUR COMP 2
6 (N/F)
5
4 (N/F)
3
2 (N/F)
1
6 (N/F)
4 (N/F)
2 (N/F)
5
3
1
6 (N/F)
4 (N/F)
2 (N/F)
5
3
1
DISJONCTEUR VENTILATEUR 2
DISJONCTEUR
COMPRESSEUR 1
DISJONCTEUR
COMPRESSEUR 2
ELECTROVANNE
(ARRET LIGNE LIQUIDE)
CIRCUIT 2
NEUTRE
(COM) 1
3 (N/F
) [VEILLE (0)]
[MARCHE (I)]
(N/O) 2
COMMUT
ATEUR
VEILLE
CONT
A
CT 4 ET 6 EN
BA
SSE TEMPERA
TURE
SONDE
THERMOST
AT
BORNES
D'ALIMENTATION
HORLOGE
TEMPORISATION
2 (6 MINS)
TEMPORISATION 3
(7 MINS)
VOYANT DEBIT D'EAU
COMPRESSEUR 2
MCB AUX
COMPRESSEUR 1
MCB AUX
VO
YANT
DEF
A
UT
DEMARRA
GE AMOR
TI
AVEC DISJONCTEUR
THERMIQUE
SI INST
ALLE
BORNES
D'ASSERVISSEMENT
CONT
A
CT DEBIT
D'EA
U (INTERNE)
CONT
A
CT DEF
A
UT
VENTILA
TEUR 1
CONT
A
CT DEF
A
UT
VENTILA
TEUR 2
DEMARREUR OU
CONT
A
CTEUR DE
DEBIT (EXTERNE)
PRO
TECTION THERMIQUE
VENTILA
TEUR 1
PRO
TECTION MO
TEUR
COMPRES
SOR 1
PRO
TECTION THERMIQUE
VENTILA
TEUR 2
PRO
TECTION MO
TEUR
COMPRES
SOR 2
OUT 1
14 (N/O)
95
(N/F
) 96
95
(N/F
) 96
TK
TK
(N/F
) TK
(N/F
) TK
(N/F
)
(N/F
)
6 (COM)
1 (L)
(N) 2
(N/O) 4
(N/F) 5
L1
L2
L3
11 (COM)
12 (N/F)
9 (L)
(N) 8
A
B
4 (N/O)
1 (N/F)
6 (N/O)
3 (N/F)
10
11
(COM) 7
(COM) 9
RELAIS (R2)
(COM)
C
(N/O) H
L
(N/C)
A
B
(N/F) 1
(N/O) 4
7
(COM)
RELAIS (R3)
B
B
1 (N/F)
4 (N/O)
(COM) 7
3 (N/F)
6 (N/O)
(COM) 9
RELAIS (R4)
7 (COM)
(N/O) 4
(N/F) 1
(COM) C
(N/O) H
L (N/F
)
A
A
RELAIS (R5)
1 (N/F)
(COM) 7
4 (N/O)
53
(N/F
) 54
15 (COM)
18 (N/O)
16 (N/F)
A1
A2
A1
A2
2
A2
A1
(COM) 9
53
54 (N/F
)
3 (N/F)
6 (N/O)
15 (COM)
16 (N/F)
18 (N/O)
A1
A2
95
(N/C) 96
(COM) C
(N/O) L
H (N/C)
(COM)
C
(N/O) H
L (N/C)
A
B
RELAIS (R1)
15 (COM)
18 (N/O)
16 (N/F)
A1
A2
1
3
5
(N/O) 2
(N/O) 4
(N/O) 6
21 (AUX)
(N/C) 22
1
3
5
(N/O) 2
(N/O) 4
(N/O) 6
21 (AUX)
10
11
7
6
6 (N/F)
4 (N/F)
2 (N/F)
5
3
1
95
96 (N/F
)
C (COM)
L (N/O)
C (COM)
H (N/O)
1
H (N/F
)
L (N/F
)
U1
V1
W1
U1
V1
W1
(N/F
)
(N/F) 1
(N/O) 4
7 (COM)
A
B
RELAIS (R6)
63 (AUX)
(N/O) 64
W
ATER FL
O
W S
WITCH CONT
A
CTS SHO
W
N WITH W
ATER FL
O
W A
T MAXIMUM RA
TE
MCB CONT
A
CTS / MCB ALARM CONT
A
CTS / MCB A
UX CONT
A
CTS SHO
W
N WITH CIRCUIT BREAKER MANU
ALL
Y S
WITCHED T
O THE ON CONDITION
ALL O
THER CONT
A
CTS SHO
W
N IN DE-ENERGISED ST
ATE BUT WITH REFRIGERA
TION CIRCUIT FULL
Y CHARGED
W
HERE CONT
A
CTS ARE MARKED (N/O) OR (N/C) ON CIRCUIT DIA
GRAM ABO
VE CONDITIONS APPL
Y
NO
TE
DISJONCTEUR VENTILATEUR 1
CONTACTEUR
VENTILATEUR 2
6 (N/O)
5
3
4 (N/O)
1
2 (N/O)
A1
A2
CONTACTEUR
COMP 1
COMPRES
SEUR 1
MCB A
UX
COMPRES
SEUR 2
MCB A
UX
PROPAC 90BM TRIPHASEE (400V ~ 3 N 50Hz)
(SE COUPE A H EN
BA
SSE TEMPERA
TURE)
(SE COUPE A H EN
BA
SSE TEMPERA