L
N
POMPE A EAU
MONOPHASEE DE
PLUS DE 3/4 HP
ALIMENTATION
MONOPHASEE
ADAPTEE A LA
CAPACITE DE LA
POMPE A EAU
L
N
L
N
L
N L
DEMARREUR N/O 4 POLES
AVEC PROTECTION CONTRE
LES SURCHARGES EL
BOBINES ET 230V 50Hz
ADAPTEE A LA POMPE A EAU
N
INSTALLATION ELECTRIQUE RECOMMANDEE POUR LA POMPE A CHALEUR
CALOREX AVEC UNE POMPE A EAU MONOPHASEE
Fig. 5
L1 L2 L3
N
5
A
SSER
VIS
SEMENT
POMPE A CHALEUR
CALOREX TRIPHASEE
1
2
3
4
7
6
SECTIONNEUR AVEC FUSIBLE A
MOINS DE 2m DE LA POMPE A
CHALEUR ET DE AL CAPACITE
CONFORME A LA FICHE TECHNIQUE
9
8
Fig. 4
EMPLACEMENT DES BORNES D'ALIMENTATION PRINCIPALE D'SSERVISSEMENT
R1
R2
R3
N
L1
L2
L3
D209450
ISS 1
DEPOSEZ LE PANNEAU DE
DE SERVICE
(FIXATION 1/4 TOUR)
ENTREE
ALIMENTATION
PRINCIPALE
RUN
STANDBY
TEMP
OK
HEAT
FAULT
CHILL
DEFROST
MAINS
CHILL
LIMIT
WATER
TEMP
N
L1
L2
L3
D209450 ISS 1
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17
DEMARRA
GE
AMOR
TI
HORL
OGE
CONT
A
CTEUR DEBIT
D'EA
U (EXTERNE)
18
11
10
*A
SSER
VIS
SEMENT
*EN DEHORS DU
CIRCUIT DE DEFAUT.
(UNIQUEMENT SUR
LES MODELES SANS
CONDENSEURS EN
TITANE.
ASSERVISSEMENT
Toutes les machines ont un dispositif d’asservissement, Les
connexions sont shuntées en usine pour pouvoir effectuer les tests de
fonctionnement.
Sur le site, le shunt doit être enlevé, et les deux fils doivent être
raccordés aux deux contacts sans tension dans l’ensemble démarreur/
contacteur/relais de la pompe à eau ou à un contacteur de débit
externe. Ainsi la Pompe à Chaleur ne démarrera pas si la pompe à eau
ne fonctionne pas (voir les figures 5 et 6).
L
N
POMPE A EAU
MONOPHASEE DE
PLUS DE 3/4 HP
ALIMENTATION
MONOPHASEE
ADAPTEE A LA
CAPACITE DE LA
POMPE A EAU
L
N
L
N
L
N L
DEMARREUR N/O 4 POLES
AVEC PROTECTION CONTRE
LES SURCHARGES EL
BOBINES ET 230V 50Hz
ADAPTEE A LA POMPE A EAU
N
INSTALLATION ELECTRIQUE RECOMMANDEE POUR LA POMPE A CHALEUR
CALOREX AVEC UNE POMPE A EAU MONOPHASEE
Fig. 5
L1 L2 L3
N
5
A
SSER
VIS
SEMENT
POMPE A CHALEUR
CALOREX TRIPHASEE
1
2
3
4
7
6
SECTIONNEUR AVEC FUSIBLE A
MOINS DE 2m DE LA POMPE A
CHALEUR ET DE AL CAPACITE
CONFORME A LA FICHE TECHNIQUE
9
8
Fig. 4
EMPLACEMENT DES BORNES D'ALIMENTATION PRINCIPALE D'SSERVISSEMENT
R1
R2
R3
N
L1
L2
L3
D209450
ISS 1
DEPOSEZ LE PANNEAU DE
DE SERVICE
(FIXATION 1/4 TOUR)
ENTREE
ALIMENTATION
PRINCIPALE
RUN
STANDBY
TEMP
OK
HEAT
FAULT
CHILL
DEFROST
MAINS
CHILL
LIMIT
WATER
TEMP
N
L1
L2
L3
D209450 ISS 1
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17
DEMARRA
GE
AMOR
TI
HORL
OGE
CONT
A
CTEUR DEBIT
D'EA
U (EXTERNE)
18
11
10
*A
SSER
VIS
SEMENT
*EN DEHORS DU
CIRCUIT DE DEFAUT.
(UNIQUEMENT SUR
LES MODELES SANS
CONDENSEURS EN
TITANE.
13
SD566252 ISSUE 51