37
1005494 ISSUE 3
MODEL
UNITS
IPT 12 ALY
IPT16 ALY
IPT22 ALY
PERFORMANCE CONDITION: Air 27°C/Water 27°C/RH 80%
Heating capacity
kW
15.0
21.0
27.5
COP range
15.0-6.6
14.8-6.4
15.0-6.5
Average COP at 50% Speed
10.6
10.3
10.3
PERFORMANCE CONDITION: Air 15°C/Water 26°C/RH 70%
Heating capacity
kW
10.5
14.5
18.0
COP range
7.7-4.6
7.1-4.6
7.5-4.6
Average COP at 50% Speed
6.4
6.3
6.3
PERFORMANCE CONDITION: Air 35°C/Water 28°C/RH 80%
Cooling capacity
kW
6.7
9.5
11.9
TECHNICAL SPECIFICATIONS
Operating air temperature
°C
-10°C to 43°C
Water heating setting range
18°C to 40°C
Water cooling setting range
12°C to 30°C
POWER SUPPLY
230V Single Phase 50Hz
Rated input power
kW
0.27-2.28
0.41-3.15
0.48-3.91
Rated input current
A
1.17-9.91
1.78-13.69
2.08-17.00
Maximum input current
A
13.5
17
20
Rated RCD type F
mA
30
30
30
Rated Fuse aM / MCB type C
A
20
25
25
Sound pressure level at 10m
dB(A)
20.8-24.5
20.4-33.7
23.0-34.4
Recommended water flow rate
m
3
/h
5.0-7.0
8.0-10.0
10.0-12.0
Pressure drop
m/kPa
0.49/4.8
0.61/6.0
0.77/7.5
Pool water connections
Inches
1½” or 50mm Female
GENERAL DATA
Net dimensions (w x d x h)
mm
954x359x648
954x429x755
1084x429x948
Packed dimensions (w x d x h)
mm
1040x445x655
1040x445x655
1130x445x985
Net weight
kg
52
68
90
HERMETIC SYSTEM
Refrigerant charge R32
kg
0.9
1.2
2.0
Minimum area requirement
m2
6.9
12.3
34.0
NOTES: Heat pump performance parameters are subject to change without notice. Always refer to the nameplate.
Global warming potential (GWP) R32 - 675.
The data is subject to modification without prior warning.