12
1005494 ISSUE 3
OWNER/INSTALLATION MANUAL
> 50 cm
Plant room
Calorex*
Wall
Calor
ex
Possible positions of a Calorex heat pump
Wall
Suitable opening
Calorex*
>70 cm
Calorex
>70 cm
>250 cm
Calorex The red lines represent the air inlet area
* Controls are obscured by the wall� Connect to
optional remote control panel or Wi-Fi before
installing the heat pump in position�
Required free areas to provide air flow to and from heat
pumps when installed in an enclosed area or where
required to pass air through a wall etc. Ensure the heat
pump is sealed against the wall so the outlet air cannot
recirculate. Ensure the hole through the wall is sealed
to avoid the outlet air entering cavities and is smooth
so the outlet air is not restricted.
Free area is the available area through which air can
pass through a grille or louvres.
Minimum free areas m
2
Model
Discharge area
IPT 8
0.169
IPT 12
0.169
IPT 16ALX
0.169
IPT 16ALY
0.229
IPT 22
0.301
IPT 28
0.301