29
1006905 ISSUE 2
Where commissioning is provided in the UK and
Ireland, this must be carried out by factory trained and
approved personnel.
The following exclusions apply to the warranty given
by Dantherm Ltd. No claims will be accepted if:
1. The heat pump is installed in any way that is not in
accordance with the current procedures as defined
by Dantherm Ltd.
2. The heat pump has been worked upon or is
adjusted by anyone other than a person authorised
to do so by Dantherm Ltd.
3. The heat pump is incorrectly sized for the
application.
4. The water flow through the machine is outside the
specified limits.
5. The water pH level and/or chemical balance is
outside the following limits:
6. The heat pump has suffered frost damage.
7. The electrical supply is insufficient or in any way
incorrect.
8. The fan amps and duct pressure are outside the
specified limits.
9. The air flow to and from the machine is outside the
specified limits.
If in doubt or if advice is required please contact
the Dantherm Group UK Service Department by
c44 (0)1621 856 611 (option 4) or email
service�department@dantherm�com
Please give
MODEL NUMBER
and
SERIAL NUMBER
of your heat pump when making technical or service
enquiries. This will assist in correct diagnosis and ensure
service can be provided with the minimum delay.
11�0 WARRANTY CONDITIONS
Acidity pH
pH
7.2 - 7.8
Total Alkalinity, as CaCO3
ppm
80 - 120
Total Hardness, as CaCO3 ppm
150 - 250
Total Dissolved Solids
ppm
1000
Maximum Salt Content
ppm
35000
Free Chlorine Range
ppm
1 - 2 Domestic
Free Chlorine Range
ppm
3 - 6 Commercial
Super chlorination
max
30ppm for 24 hrs
Bromine
ppm
2 - 5
Baquacil
ppm
25 - 50
Ozone
ppm
0.9 Max
Maximum Copper Content ppm
1
Aquamatic Ionic Purifier
ppm
2 Max