background image

Page 10

Page 11

7

16

11

13

17

(Wrapper not shown for clarity)

15

9

10

14

3

2

4

5

6

8

12

If parts required are not
identified, please contact
Calomax Limited

1

*

* Includes nuts, washers, etc.

Exploded parts view Cascade -4

(To be read in conjunction with the spare parts list)

Содержание CASCADE-4

Страница 1: ...N AND SERVICING INSTRUCTIONS Calomax Limited Lupton Avenue Leeds LS9 7DD Tel 0113 249 6681 Fax 0113 235 0358 e mail service calomax co uk www calomax co uk Please read these instructions carefully bef...

Страница 2: ...CLEANING 8 SERVICE INSTRUCTIONS 9 12 13 EXPLODED DIAGRAM 10 11 SPARE PARTS 14 15 ACCESSORIES 16 WIRING DIAGRAM 17 TROUBLE SHOOTING 18 WARRANTY 19 PRODUCT SPECIFICATION 20 CHECK LIST Before commencing...

Страница 3: ...TING THE SUPPLY PIPE MUST BE THOROUGHLY FLUSHED OUT TO ENSURE THAT FOREIGN MATTER DOES NOT BLOCK OR ENTER THE SOLENOID VALVE The boiler must be connected to a potable water supply using the food grade...

Страница 4: ...id orange indicating that the boiler is full and up to temperature Subsequent Use After the boiler has finished the commissioning cycle and water is drawn from the tap water will be replaced in short...

Страница 5: ...of the boiler is showing solid colour the machine has been starved of water for in excess of 20 minutes and the solenoid valve has been disabled to prevent damage to the solenoid coil through overheat...

Страница 6: ...apper not shown for clarity 15 9 10 14 3 2 4 5 6 8 12 If parts required are not identified please contact Calomax Limited 1 Includes nuts washers etc Exploded parts view Cascade 4 To be read in conjun...

Страница 7: ...element causing failure If in doubt protect the element by hand filling with water to the level of the draw off tap before switching on the electrical supply to the boiler General function The printe...

Страница 8: ...P BODY PRINTED CIRCUIT BOARD Inc TRIAC LIGHT PCB ELEMENT 3kW THERMISTOR ASSEMBLY KIT SOLENOID VALVE BODY LID GASKET WATER INLET HOSE MANUAL RESET THERMAL CUTOUT LEVEL PROBES KIT BODY LID GROMMET 1 2 3...

Страница 9: ...BLACK BLUE PINK BROWN ORANGE WHITE BLACK RED YELLOW WHITE BLACK BLACK RED N L BLUE BLUE L N BLACK YELLOW GREEN YELLOW GREEN RED RED COLD WATER INLET SOLENOID VALVE ELEMENT TRIAC PCB HIGH NORMAL LOW L...

Страница 10: ...place P C B BASIC TROUBLE SHOOTING Calomax have manufactured water boilers in the UK for over 50 years We are proud of our products and the back up service we provide Properly maintained and serviced...

Страница 11: ...Average Flow rate from tap Stan dard nozzle 2 5 Litres Minute Voltage 220 240 V ac 50 60 Hz Power rating 3kW MAX PLEASE ENTER SERIAL NUMBER FOR FUTURE REFERENCE PLEASECONTACTOURSERVICEDEPARTMENTFORAS...

Отзывы: