background image

Whozz Calling? POS 

 

Technical Manual 

[V1.2 - 03/17/2006] 

 
 

Introduction 

 

The Whozz Calling? POS reports telephone line number and Caller ID information.  Caller ID information consists of 
date, time, caller’s number and caller’s name (if sent).  This information is sent via serial stream to any serial device 
such as a printer or a computer immediately after Caller ID data is captured.  Data can be sent at either 9600 or 1200 
Baud.  Two different formats are available.  The CallerID.com format conforms with all other Whozz Calling? products.  
The limited format matches the TCI, MLX series format.  If multiple units are to be connected together, each individual 
unit can be set for different line numbers.  All options, formats, and addresses are set using DIP switches located on the 
front panel of the unit. 
 

Telephone Line and Serial Communication Requirements 

 

The monitoring unit is designed to collect call data from standard telephone lines (trunk or CO lines) coming into your 
building.  It will not work properly if connected to extensions (or station) lines coming from a telephone switch.  
Connect the unit only to analog loop start, ground start, or Centrex

 phone lines.  It is not designed for ISDN, T1, T3, 

E1, E3, DID, or Digital Centrex type phone lines 
 
The unit can be connected to a printer or to a computer through a serial port.  A serial printer connects using a null 
modem adapter or null modem cable.  A parallel printer requires a serial to parallel converter as well as a null modem 
adapter.  If connected to a computer, the serial port must be free of COM Port and IRQ conflicts and dedicated to the 
monitoring unit.  The unit can work with any serial port regardless of the COM number and/or IRQ it is using. 
 

Quick Start Procedure 

 

In order to see Caller ID information on your computer, you will need some type of serial communications program such 
as HyperTerminal, PC Plus, PC Anywhere, etc.  Follow the instructions below for connecting to your computer and refer 
to Fig. 1. 

 

 

1.  Connect the supplied 9 pin cable to the female serial connector on unit marked “To Computer”.   

 

2.  Connect this same cable to an available serial port on the computer. 

 

3.  Plug in 2-wire RJ11 phone lines into the modular phone jacks on the unit. 

 

4.  Use any terminal emulation program or modem software set to terminal mode. 

 

5.  Set communication parameters to 9600 Baud, 8 Bit, 1 Stop, No Parity. 

 

6.  Plug in the power supply and make sure the red channel LEDs light.

*

 

 

7.  Make a phone call to one of the lines connected to the unit.  The Caller ID information will appear  

  on 

your 

screen. 

 

*

  The power up sequence of the unit will flash the LEDs and a couple of seconds.  The unit will send the firmware 

version number of each channel to the serial port when the DIP switches are positioned to send the CallerID.com format 
(Fig. 2a).

Содержание Whozz Calling? 4 POS Caller ID

Страница 1: ...ng POS Caller ID Interface Unit Caller com ID ID CALLING WHOZZ POS Caller ID 4 CALLING WHOZZ POS Caller ID 8 Technical Manual for Whozz Calling POS Series 4 and 8 Line Units Belcore 202 USA DTMF Signaling Version ...

Страница 2: ...computer through a serial port A serial printer connects using a null modem adapter or null modem cable A parallel printer requires a serial to parallel converter as well as a null modem adapter If connected to a computer the serial port must be free of COM Port and IRQ conflicts and dedicated to the monitoring unit The unit can work with any serial port regardless of the COM number and or IRQ it ...

Страница 3: ... 4 Caller ID Signal Type Transmitted by TelCo Off FSK On DTMF 5 Baud rate Off 9600 On 1200 7 Output Format Off CallerID com On TCI 8 Unit model Off 8 line On 4 line 9 Not Connected 3 2 4 5 1 6 7 8 Device CID Signal Baud Rate Format 4 8 Line N C 1 3 4 5 7 8 9 Caller com ID ID Standard RS232 1200 or 9600 Baud Default is 9600 Baud 8 Bit 1 Stop No Parity Top jack connects to bottom jack of addional un...

Страница 4: ...it 3 in the same manor CALLER ID DELIVERY TYPE Caller ID signaling is sent by the local phone company s central office in either of two different electronic formats Frequency Shift Keyed FSK signaling is used in the countries were newer central office equipment is installed such as the US Canada and Australia In countries or regions where older central office equipment is used Caller ID is deliver...

Страница 5: ...G A0 09 26 11 28 AM 770 263 7111 CALLERID COM 03 I S 0000 G A0 09 26 11 28 AM 770 263 7111 CALLERID COM NOTES No dashes are inserted when the UK BT ETSI type Caller ID is captured DIP switch 4 set ON All fields left justified 1 space separates each field Fig 2b TCI Format Fig 2b TCI Format DIP switch 7 set ON DIP switch 7 set ON R C F L 03 9 26 11 28 AM 770 263 7111 CALLERID COM 03 9 26 11 28 AM 7...

Страница 6: ...onnected to the back of the unit using modular jacks Input and output ports are provided for wiring systems using 2 wire RJ11 connections If the wiring coming into your building does not terminate in modular jacks contact your telephone vendor to add these modular connections CONNECTING DIRECTLY TO A PRINTER Printers have either a serial or parallel input Most newer printers use parallel connectio...

Страница 7: ...pback Connector to the cable the other end is connected to the serial port on the PC 8 Type any character a If the character you typed shows on the screen the serial port is functioning properly the test is positive b If you do not see the character COM port and click OK c Select Call Connect and type any character again and repeat above as necessary 9 If you obtain a positive result close HyperTe...

Страница 8: ...lephone Connections Whozz Calling POS 8 Line Model L1 L2 L5 L6 L3 L4 L7 L8 Even if your telephone system switch is Caller ID capable it will not pass analog Caller ID Therefore the POS series units must be connected to the phone lines coming into the building from the telephone company These lines are branched split or half tapped and connected to the input jacks of the monitoring unit If these li...

Страница 9: ... repair facility or damage attributed to an act of God Lightning is considered an act of God CallerID com makes no other warranty either expressed or implied with respect to this product If a problem develops concerning this product contact CallerID com directly for a Return Material Authorization RMA FCC Information This unit is designed to conform to federal regulations and complies with Part 68...

Страница 10: ...d acts as a control line When units are not transmitting data this line resides at 9 VDC Upon transmit the unit pulls this line to 9 VDC Other Whozz Calling units connected will detect this as a busy condition and will not transmit until the line returns to 9 VDC If connecting to a 25 pin serial port on the computer we suggest using a 9 to 25 pin serial adapter The pin outs on a 25 pin serial port...

Страница 11: ...3107 D Medlock Bridge Road Norcross GA 30071 800 240 4637 770 263 7111 Caller com ID ID ...

Отзывы: