108
Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© Calix. All Rights Reserved.
For example:
Maximum DS Train Rate
Minimum DS Shapeable Rate
50M
1.5M
40M
1.2M
30M
900K
20M
600K
10M
300K
5M
150K
1.5M
45K
Note:
If the CIR/PIR is lower than the minimum-shapeable rate,
it is not enforced; downstream traffic is allowed up to the
minimum rate.
Parameters
You can provision the following parameters for Ethernet bandwidth profiles:
Parameter
Description
Valid Options
Name*
Name of the bandwidth profile.
Committed Rate
for Upstream
Committed information rate for upstream traffic. Where rates may be
specified as follows:
In 64 kbps increments up to 2 Mbps
In 1 Mbps increments between 2 Mbps to 1000 Mbps
0 kbps disables the meter
Use "m" suffix for Mb/s or "g" for Gb/s in whole number increments.
0-2048kpbs, 0-
1000Mbps, 1Gbps
kbps in 64k increments
Peak Rate for
Upstream
Peak information rate for upstream traffic. Where rates may be
specified as follows:
In 64 kbps increments up to 2 Mbps
In 1 Mbps increments between 2 Mbps to 1000 Mbps
0 kbps disables the meter
Use "m" suffix for Mbps or "g" for Gbps in whole number increments.
0-2048kpbs, 0-
1000Mbps, 1Gbps
kbps in 64k increments
Peak Rate for
Downstream
Peak information rate for downstream traffic. Where rates may be
specified as follows:
In 64 kbps increments up to 2 Mbps
In 1 Mbps increments between 2 Mbps to 1000 Mbps
0 kbps disables the meter
Use "m" suffix for Mbps or "g" for Gbps in whole number increments.
0-2048kpbs, 0-
1000Mbps, 1Gbps
kbps in 64k increments
Downstream Peak
Burst Size
Peak burst size for downstream traffic.
Use "k" suffix for Kbytes (4 to 16000kbps)
Use "m" suffix for Mbps (0 to 16 mbps)
Use whole number increments
4-16000 Kbps