UPS Harness Wiring 

Pin # 

Color 

Function 

1 Brown  48 

Vdc 

Blue 

48 Vdc Return 

3 Black  Signal 

Return 

Green 

Operating in Battery Mode 

Red 

Replace Battery Indication 

Yellow 

Battery Missing (Not Connected) 

7 Orange  Low 

Battery 

Condition 

 

Auxiliary UPS Connections 

For ONT Model 560 deployments that utilize more than 8 POTS lines, an external battery 
pack may be used in order to ensure life-line services remain on for a full 8 hours. 

Note:

 The External Battery Pack (EBP) comes with a 36 inch (91.4 cm) cable that attaches 

to the primary UPS. Make sure you locate the EBP within this distance. 

1. 

Remove the battery cover by depressing the battery cover release tabs on the bottom 
edge of the cover. 

2. 

Remove the battery temporarily. 

3. 

Place the EBP against the wall in the desired location, within 36 inches of the primary 
UPS. 

 

CAUTION!

  Do not operate the UPS in conditions outside the specified 

values for temperature and humidity. Refer to the Product Data Sheet for 
details. 

Make sure the UPS is not installed under water pipes which may leak or 
drip from condensation. 

4. 

Using the keyholes as a template, drill holes for (2) two screws or other suitable 
anchoring fasteners (not provided). 

5. 

Insert a screw into each hole, leaving 3/16 inch (48 mm) of the screw protruding from 
the wall. 

6. 

Align the key slots on the bottom of the UPS with the screws and slide the unit down 
into place. 

7. 

Tighten the screws once the UPS is in place. 

© 2001-2007 Calix. All Rights Reserved. 

Содержание 560 SBU ONT

Страница 1: ...Calix 560 SBU ONT Installation Guide November 2007 220 00215 Rev 11...

Страница 2: ......

Страница 3: ...s 7 Data Services 7 Service Delivery 7 Calix Model 560 ONT 8 ONT Enclosure 9 Main Electronics Module MEM 10 Power Supply 11 Component Locations 11 Chapter 2 Pre Installation Requirements 13 Overview 1...

Страница 4: ...und 26 Preparing the Drop Cable 26 Installing the Power Cable 27 Making the Fiber Connection 28 Installing the Main Electronics Module 30 Installing Expansion Modules 31 Connect to Subscriber Services...

Страница 5: ...a brief overview of Calix FTTH network a description of the Model 560 ONT the various configuration options and components required to establish the network Additional technical information as well as...

Страница 6: ...6 and 11 miles are supported with a 16 way split and distances of 11 to 12 4 miles are supported via an 8 way split For reference a block diagram of the Calix GPON Architecture is provided Voice Servi...

Страница 7: ...tal video feed The SVS signal is sent to a data switch that combines this video signal with the data signal before forwarding it to the shelf The shelf combines the Voice SVS and Data and converts it...

Страница 8: ...cted remotely up to 500 feet from the unit The 500 feet off premises extension capability allows for remote telephone or other accessory locations y All off premises extensions require additional surg...

Страница 9: ...al signals that are transmitted to the central office and vice versa for headend signals The ONT has an outer and inner enclosure The outer enclosure has the following characteristics y 19 125 inches...

Страница 10: ...ng Optional Main Electronics Module MEM The MEM provides the telephony signal processing transport and power supply circuitry for the ONT This circuit card is mounted inside a protective electro magne...

Страница 11: ...ses where many telephony lines are needed more than 8 an external battery pack will be required The dimensions for both UPS units is identical Component Locations Components within the Calix Model 560...

Страница 12: ...12 Proprietary Information Not for use or disclosure except by written agreement with Calix 2001 2007 Calix All Rights Reserved...

Страница 13: ...the Calix Model 560 ONT and the Uninterruptible Power Supply UPS Topics covered include y General Installation Assumptions y Site Preparation y ONT Mounting Access Points and Clearances y UPS Mounting...

Страница 14: ...d to consider the proper clearances needed for swinging covers latches or locks Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15...

Страница 15: ...use or disclosure except by written agreement with Calix ONT Mounting Access Points and Clearances Dimensions access points and clearances for the Model 560 ONT are detailed in the illustration below...

Страница 16: ...in the event a loss of primary power should occur A rear view of the UPS mounting holes is provided below for reference Important The AC power cord shipped with the UPS is 8 2 43 M long Make sure a st...

Страница 17: ...ectrodes once bonded together become the buildings primary ground point The above named agencies do not require any additional electrodes to be installed unless the ONT is located more then 20 feet aw...

Страница 18: ...orporate a primary ground protection device for each off premises instance WARNING This device does not incorporate a primary protector If off premises coax or telephone cable lengths exceed 140 feet...

Страница 19: ...0 ONT Every Model 560 ONT installation includes the following components y Outer enclosure inner cover outer cover security screws 4 four populated tip and ring connectors with RJ 11 plugs attached we...

Страница 20: ...Tools Required In order to install the ONT the following tools are necessary y 3 8 Drill for drilling the mounting holes y Drill Bits appropriate for wall anchors or fasteners of choice y 7 16 nut dr...

Страница 21: ...t port y Screws for mounting local power converter y 1 60 p n 12 219 Hi cap riser pipe y TexWipe Alco pad for fiber cleaning TX806 y Texwipe cloth for fiber cleaning TX304 y SC APC connectors for fibe...

Страница 22: ...22 Proprietary Information Not for use or disclosure except by written agreement with Calix 2001 2007 Calix All Rights Reserved...

Страница 23: ...cal fiber connector CAUTION Use of controls adjustments or procedures other than those specified herein may result in hazardous radiation exposure Tips on Handling Fiber Optic Cable Follow these tips...

Страница 24: ...ONT in it s final mounted location Only surface mount the enclosure Do not install siding or other building material around the outside of the enclosure Doing so could create excessive heat and produ...

Страница 25: ...Location Installation Procedure DANGER High voltage electrical and pressurized natural gas lines may be present Make sure you fully understand the locations of these and all other utility connections...

Страница 26: ...he riser pipe Make sure to leave 3 feet of exposed buffer tube for later splicing 2 Remove the grommet on the bottom left side of the ONT chassis and pierce the grommet with the sharpened end of a pen...

Страница 27: ...taches Here 1 4 inch nut Installing the Power Cable To install the power cable 1 Pierce a hole near the back of the power supply grommet 2 Slip the power cord through the grommet Note A majority of th...

Страница 28: ...Cord Here 5232 Making the Fiber Connection To make the fiber connection 1 Remove the splice tray cover by pulling out on popping the cover off the splice tray 2 Remove the splice tray by removing the...

Страница 29: ...ding tray upright tie wrap to the left Important Do not over tighten the tie wraps which secure the fiber optic cable to the splice tray Excessively tightened tie wraps will cause an undesirable refra...

Страница 30: ...er to the figure below for completing the following steps 1 Remove the MEM from its anti static plastic blister pack container 2 Orient the board with the power connector positioned in the upper left...

Страница 31: ...cover details the location of the phone jacks Power Cord Connection 3332 Installing Expansion Modules To install expansion modules 1 Refer to the appropriate installation instruction supplied with eac...

Страница 32: ...riable in size choose the proper one for your application 3 Secure the conduit if present to the ONT unit using the knock outs provided 4 Connect the telephone lines from the subscriber to the colored...

Страница 33: ...tallations or where more than one Model 560 ONT is to be supported instructions can be found in the Alternate Configurations chapter Internally Mounted UPS The ONT is powered via an uninterruptible po...

Страница 34: ...ws and slide the unit down into place 8 Tighten the screws once the UPS is in place 9 Replace the battery and connect the battery terminals to the UPS connector 10 Install the AC power cord into the s...

Страница 35: ...mediately wash off any spills on your body or equipment with water Seek medical attention if the sulfuric acid gel makes contact with your body Insulate metallic tools that will be used near the batte...

Страница 36: ...stance 1 Remove the battery cover by depressing the battery cover release tabs on the bottom edge of the cover 2 Remove the battery temporarily 3 Place the EBP against the wall in the desired location...

Страница 37: ...es power source Both the green AC Power and DC Power indicators on both UPS s should light 2 Return to the ONT plug in the power cord to the MEM and view the LEDs A properly installed ONT Model 560 wi...

Страница 38: ...he Troubleshooting chapter of this manual POWER PROCESSOR HEALTH PON HEALTH TE L OFF HOOK BATTE RY PRESENT PRESENT PRESENT STATUS STATUS PORT 1 PORT 1 PORT 1 PORT 2 PORT 2 PORT 2 PORT 3 PORT 3 PORT 4...

Страница 39: ...E USE CATV 4 Data 4 Expansion Module Affix Label Here Line 4 Line 3 Line 2 Line 1 S TANDARD SUBSCRIBER CONNECTIONS MAIN BOARD FIBERPOINT 440 EX PANSION MODULE CONNECTION S TELEPHON Y OU T CUS TOMER WI...

Страница 40: ...40 Proprietary Information Not for use or disclosure except by written agreement with Calix 2001 2007 Calix All Rights Reserved...

Страница 41: ...ed ALERT A Class I laser product is used in this equipment Use an optical power meter to identify active fibers Never assume laser power is turned off or that the fiber is disconnected at either end A...

Страница 42: ...ut hackles or lips If major flaws are noticed the process must be repeated Inspect the fiber end under a microscope to ensure proper finish Note Small scratches on the face or small pits on the outsid...

Страница 43: ...2 Use a pad or a wipe saturated with optical grade isopropyl alcohol to gently wipe the cylindrical and end face surfaces 3 Use compressed gas to blow dry the connector surfaces or allow them to air d...

Страница 44: ...44 Proprietary Information Not for use or disclosure except by written agreement with Calix 2001 2007 Calix All Rights Reserved...

Страница 45: ...Operation When power is first applied to the ONT the LEDs located on the MEM will indicate the status of each component within the unit as it goes through its start up routine POWER PON HEALTH TEL OFF...

Страница 46: ...not achieved downstream synchronization Tel Off Hook On One or more of the POTS lines are off hook Off No POTS lines are in use off hook Battery Present Blink A battery is connected to the MEM and the...

Страница 47: ...lled on the card A Word about Troubleshooting Troubleshooting a communications device is simple if you keep the following basic principles in mind y Anytime you have a random or intermittent problem i...

Страница 48: ...lace UP S as required Contact Central Office Is the ONT functioning properly Is the ONT Provisioned Is the ONT Connected Is there power to the ONT No No No No No 48 VDC Out Yes Replace UPS Unit Check...

Страница 49: ...quipment CPE which includes various models of the ONT This document also provides NEC requirements for installing a ground Grounding Options The grounding requirements for various ONT models differ de...

Страница 50: ...ticle 250 56 of the code To be properly grounded the ONT must be directly bonded to the building s AC utilities earth ground electrode using a 6 AWG copper conductor The earth electrode can be a metal...

Страница 51: ...irect path free of sharp bends will help to lower the impedance of the ground circuit Note Grounding conductors should never be placed inside a metallic conduit unless bonded at both ends of the condu...

Страница 52: ...les of ground conductivity The earth acts like it is made up of layers that bear a resemblance to an onion Like an onion the earth is made up of expanding sections or peels layers An electrode placed...

Страница 53: ...earth electrode Grounding system tests are commonly made with a full of potential test set Within the test set is a AC current source a voltage meter and a number of test terminal binding posts The A...

Страница 54: ...e is used as a probe and placed into the ground at a number of points that are along a line between the outer electrodes Each time the test probe is placed into the ground a resistance reading is take...

Страница 55: ...ds should be kept of each CPE installation In some locations extremely high earth ground resistance is present In these locations chemicals that lower earth resistance can be added to the earth that s...

Страница 56: ...ve Humidity 0 95 non condensing Drop Length 328 feet 100 M Maximum with CAT5 cable Storage Relative Humidity 0 95 non condensing Video RF Analog Digital ports via F connector RG 58 Altitude 200 to 10...

Страница 57: ...m Signal Strength within AGC range 14 dBmV Flatness peak to valley 6 dB Maximum Channel Loading Up to 80 RF CATV channels Video PON Digital RF Output Recommended Clearances Nominal Impedance 75 ohm Le...

Страница 58: ...cord Mechanical Telephony Interface Height 20 inches 50 8 cm Interface GR 909 Single Party message Telephone Service with On hook transmission loops start POTS with Customer and Class feature support...

Страница 59: ...59 Proprietary Information Not for use or disclosure except by written agreement with Calix 2001 2007 Calix All Rights Reserved...

Страница 60: ...60 Proprietary Information Not for use or disclosure except by written agreement with Calix 2001 2007 Calix All Rights Reserved...

Отзывы: