NEC and Grounding 

A very important aspect of any ONT installation is to comply with the National Electric 
Code (NEC), as well as all state and local codes. Article 800 of the NEC requires the ONT to 
be grounded according to Article 250.56 of the code. To be properly grounded, the ONT 
must be directly bonded to the building’s AC utilities earth ground electrode using a #6 
AWG copper conductor. The earth electrode can be a metallic cold water pipe or a copper 
clad steel rod that has been driven into the ground to a depth of at least 8 feet. 

Metallic cold water pipes that run under ground for a distance of at least 10 feet are 
considered the best ground electrodes. The NEC requires that if cold water pipes are used 
they must be within 5 feet of the outside wall that the ONT is mounted on. 

In the event that the ONT is installed more than 20 feet from the building AC utility earth 
ground electrode, a suitable secondary ground electrode must be provided. The secondary 
ground must be bonded to the building’s primary earth electrode. A bonding jumper of #6 
AWG copper must be used between the two electrodes. 

 

Содержание 500 Series

Страница 1: ...Calix ONT Grounding Implementation January 2007 220 00178 Rev 10...

Страница 2: ......

Страница 3: ...Not for use or disclosure except by written agreement with Calix 2001 2007 Calix All Rights Reserved Contents Introduction 5 Grounding Purpose 5 NEC and Grounding 6 Testing the Earth Electrode 7 Full...

Страница 4: ...4 Proprietary Information Not for use or disclosure except by written agreement with Calix 2001 2007 Calix All Rights Reserved...

Страница 5: ...case would cause the over current device to trip thereby removing the power to the device y The protection and survivability of the electronics equipment High voltage spikes that occur during electric...

Страница 6: ...The earth electrode can be a metallic cold water pipe or a copper clad steel rod that has been driven into the ground to a depth of at least 8 feet Metallic cold water pipes that run under ground for...

Страница 7: ...depends on the chemical makeup and ambient moisture content of the soil The testing of an electrode measures the effectiveness of the earth electrode to provide electrical contact with the earth The...

Страница 8: ...re measurements are taken beyond this point the amount of resistance to earth will start to increase again The test setup as illustrated below uses an Earth Resistance Megger to determine the resistan...

Страница 9: ...ectrode being tested and the outer current electrode may be limited by the physical characteristic of the surrounding area or the length of the test conductor being used It is not uncommon for the out...

Страница 10: ...should be kept for each ONT installation In some locations extremely high earth ground resistance is present In these locations chemicals that lower earth resistance can be added to the earth that sur...

Отзывы: