background image

Ver. 18/12/2020 | Calistair C300

IV

Table of contents

4.  TRANSPORT, HANDLING, STORAGE

4.1 Transport 

21 

4.2  Handling and storage 

22 

5  ASSEMBLY, INSTALLATION, COMMISSIONING

5.1 Assembly 

23

5.2  Place device 

24

5.3 Commissioning 

25

6  FACTORY SETTINGS

 

26

7 OPERATION

7.1  Operating modes 

27

7.2  Switch on / switch off / regulate device

 

28

 

7.2.1  Switch on device 

28

 

7.2.2  Switch off device

 

28

 

7.2.3  Select air flow via adjustment wheel

 

28

8 MAINTENANCE

 

29

8.1  Change prefilter

 

31

8.2  Change high-performance filter (HEPA filter)

 

33

8.3  Change UVC fluorescent tubes

 

34

8.4  Replace UVC fluorescent tube in case of glass breakage

 

37

9  CLEANING AND DISINFECTION

 

40

10. TROUBLESHOOTING

 

41

11.   DECOMMISSIONING

 

42

11.1 Disassembly 

42

11.2  Disposal, scrapping 

42

ANNEX

Parts lists 

43

EC Declaration of Conformity 

43

LIST OF ILLUSTRATIONS

 

43

Содержание C300

Страница 1: ...CALISTAIR C300 TRANSLATION OF THE ORIGINAL OPERATING INSTRUCTIONS Year of construction 2020 Made in Europe Ver 18 12 2020 Decontamination plant Read carefully before use...

Страница 2: ......

Страница 3: ...r data 11 2 SAFETY 2 1 Personal qualification 12 2 2 Personal protective equipment 12 2 3 Safety components 12 2 4 Dangers 13 2 4 1 General dangers 13 2 4 2 Dangers during assembly commissioning and o...

Страница 4: ...gulate device 28 7 2 1 Switch on device 28 7 2 2 Switch off device 28 7 2 3 Select air flow via adjustment wheel 28 8 MAINTENANCE 29 8 1 Change prefilter 31 8 2 Change high performance filter HEPA fil...

Страница 5: ...ode or as entrepreneurs have their registered office in the Federal Republic of Germany Scope of warranty services Repair or replacement of the device by Calistair Calistair has the right to choose wh...

Страница 6: ...scretion The guarantee does not include filters UV C lamps and other wear parts Intentional and unintentional damage by the user or third parties after transfer of risk damage resulting from non compl...

Страница 7: ...thout prior notice All representations and pictures are protected by copyright Calistair September 2020 1 5 Other applicable documents In addition to these operating instructions please observe the da...

Страница 8: ...n or handling steps Result of the handling instruction Individual handling instructions without chronological sequence are presented as follows Handling step disordered Representation of enumerations...

Страница 9: ...can lead to reversible slight personal injury Listing of all measures that must be taken to avoid the consequences NOTE Indicates a potentially dangerous situation which can lead to damage to propert...

Страница 10: ...hot surface Warning of UV radiation Warning of hazardous voltage Mandatory sign General mandatory sign Use hand protection Use mask Prohibition sign General prohibition sign UV 1 6 3 Symbols used Imp...

Страница 11: ...andard limits set at the time of manufacture of the product have not been exceeded All necessary measures have been taken for the product to protect health and safety provided the product is used for...

Страница 12: ...t correspond to the target group definition in chapter 1 1 2 2 Personal protective equipment Cutting and skin injuries may occur during maintenance measures and repair work Therefore wear protective g...

Страница 13: ...operate the device in completely assembled condition Do not sit or stand on the device Do not place anything on the device Make sure that no liquids enter the device Do not insert any objects or fore...

Страница 14: ...without supervision Wait for the fan to stop completely at least 30 seconds before any cleaning or maintenance Never open the device while the power cable is plugged in Only use spare and wear parts...

Страница 15: ...ce Where has something happened What exactly has happened How many people are affected What type of injury emergency exists Waiting for further queries 5 Provide first aid until the first aider has ar...

Страница 16: ...Fixed castors Prefilter insert UVC fluorescent tubes High performance filter HEPA filter Lateral air intake Fan Filter drawer Housing Adjustment wheel Power switch Reactor honeycomb plates Power conne...

Страница 17: ...ans that the interior of the device remains largely free of coarse dust With the high performance filter the room air can also be cleaned of fine dusts allergens and mineral air pollutants such as soo...

Страница 18: ...xt to heaters fireplaces or devices that use gas In environments with strong temperature fluctuations as this can lead to condensation water inside The device is not intended for drying objects 3 4 Na...

Страница 19: ...led 1x HEPA filter insert pre assembled 1x Power cable 230 V 1x Operating instructions 1x Quick start guide 1x Allen key 2 5 mm 3 6 Technical data General Noise level LEX 8h 65 dB A Dimensions WxDxH 3...

Страница 20: ...splays 3 7 1 Power switch The power switch is located on the top of the device For further information see chapter 6 3 7 2 Adjustment wheel The adjustment wheel is located on the top of the device and...

Страница 21: ...o prevent injury to persons or damage to property Incorrect operation due to non compliance with the operating instructions can cause injury or damage 4 1 Transport Unplug the power plug of the device...

Страница 22: ...the device as follows Standing upright In frost free dry and adequately ventilated indoor spaces Store the power cable as follows Kink free Disconnected from the device Observe the following points fo...

Страница 23: ...from cardboard box 2 Remove foil bag 3 Select location 4 Connect power cable to the device as shown in the figure 5 ASSEMBLY INSTALLATION COMMISSIONING WARNING Risk of suffocation due to foil bag Foil...

Страница 24: ...able presents a tripping hazard The control panel and housing cover should be easily accessible 5 2 Place device NOTE Damage to property possible due to defective substrate Damage to the device possib...

Страница 25: ...grounded socket 4 Switch on device see chapter 7 2 1 5 Select air flow via adjustment wheel see chapter 7 2 3 Consider the following location factors for an optimal result to improve air quality Later...

Страница 26: ...Calistair C300 Adjustment wheel left minimum air flow rate right maximum air flow rate 0 off I on In the factory setting the adjustment wheel is in the left stop position The power switch is set to 0...

Страница 27: ...in the range between 40 and 60 Too dry air can cause irritated mucous membranes and eyes thus increasing the susceptibility to infections Eliminate or reduce possible causes of air pollution or pollut...

Страница 28: ...ir flow rate right maximum air flow rate 7 2 Switch on switch off regulate device 7 2 1 Switch on device Insert plug of the device into the socket Set the power switch to I to switch on the device Dev...

Страница 29: ...into the component Do not wear loose or hanging garments or jewellery when working on moving parts Protect long hair with a hairnet DANGER Risk of injury due to UV C radiation Risk of injury due to op...

Страница 30: ...t may be emitted Wear protective gloves NOTE Inhalation of dusts If the filter is dirty dust may be emitted Dust protection mask recommended WARNING Burn due to hot surface Hot surfaces in operation d...

Страница 31: ...arpets in the environment Number of people and animals in a room Number of air purifiers in a room Component Interval Prefilter Every 3 months HEPA filter Every 24 months depending on degree of pollut...

Страница 32: ...sing cover with an Allen key 2 5 mm 4 Remove housing cover Fig 1 5 Pull the prefilter insert out of the mounting on the underside of the housing Fig 2 6 Push the new prefilter insert into the mounting...

Страница 33: ...ed Wear protective gloves Always replace the HEPA filter do not clean Clean hands thoroughly after maintenance work 8 2 Change high performance filter HEPA filter 1 Switch off device 2 Pull power plug...

Страница 34: ...facing upwards Push in filter completely 9 Push filter drawer into the housing up to the stop 10 Attach housing cover 11 Tighten screws Device is ready for operation 8 3 Change UVC fluorescent tubes...

Страница 35: ...osal NOTE Damage to the metal surface of the reactor honeycomb plate The coating of the metal surface can be damaged by touch Avoid touching the metal surface 1 Switch off device 2 Pull power plug 3 L...

Страница 36: ...letely until the light tube can be easily removed upwards 9 Remove fluorescent tube Remove all fluorescent tubes in this way Fig 3 10 Press new UVC fluorescent tubes with the contact pins into the lam...

Страница 37: ...eakage Glass breakage may cause injury at sharp edges Wear work gloves when removing the fragments and the broken lamps Clean your hands thoroughly after the repair If the device was in operation at t...

Страница 38: ...tinue to ventilate while removing the fragments 7 Loosen screws on the housing cover with suitable tool 8 Remove housing cover 9 Remove fragments and broken fluorescent tubes with gloves 10 Hold fluor...

Страница 39: ...scent tubes with the contact pins into the lamp sockets from above until they audibly click into place 18 Push both reactor honeycomb plates carefully into the mounting until it stops 19 Attach housin...

Страница 40: ...device 2 Pull power plug 3 Let device cool down for at least 30 minutes 4 Wipe external surfaces with a dry or slightly damp cloth Device is cleaned NOTE Damage to the surface and interior Do not use...

Страница 41: ...safety switches are pressed The high performance filter HEPA filter is not or not correctly mounted Insert filter insert in filter drawer Push in filter drawer completely Low air flow at air outlet P...

Страница 42: ...Disposal scrapping Waste electrical equipment does not belong in the household waste Electrical and electronic equipment must be disposed of separately from general household waste through government...

Страница 43: ...pare parts UVC fluorescent tube Filter Wear parts UVC fluorescent tube Filter EC Declaration of Conformity The EC Declaration of Conformity can be obtained from our customer service List of illustrati...

Страница 44: ...atus 18 12 2020 Made in Europe Manufacturer Calistair SAS 223 rue Pasteur 77000 Vaux le P nil Tel 33 1606 346 34 www calistair com Contact Calistair GmbH www calistair C300 com kontakt calistair com P...

Отзывы: