Remote Control & Timer Delay Closing
Figure 2
3
A.
Remote Control delay closing
1.
Choose time delay to activate operator between 0~6 seconds by turning knob on
DELAY
1
7
Features
1. On your gate operator circuit board in the bottom, turn Dip Switch #2 to the ON
position. Figure 2
4
2. On the gate operator circuit board, adjust the delay by turning the second blue knob
from 0-60 seconds. Figure 2
5
Auto Close
This allows your gate to automatically close after opening it.
Figure 2
4
Figure 2
5
Figure 22
Test ERD every 6 months.
Electronic Reversing Device (ERD)
The Electronic Reversing Device (ERD) is a feature on the circuit board which detects when the gates
comes in contact with an obstruction, causing the gate to reverse.
The open and close knobs determine the amount of force required to reverse the gate (figure 22). We
generally recommend leaving the knob at 75, or around a 3:00 position. You may adjust the positions based
on your needs.
If the gate reverses without touching an obstruction, the ERD is too sensistive. If the gate does not reverse
when it hits an obstruction, the ERD is not sensitive enough.