SALT CHLORINATION SYSTEM REPLACEMENT CELL  

 

INSTALLATION AND OPERATION MANUAL 

 

READ AND FOLLOW ALL INSTRUCTIONS 

SAVE THESE INSTRUCTIONS 

 

 

Содержание CMARCHA40-1Y

Страница 1: ...1 SALT CHLORINATION SYSTEM REPLACEMENT CELL INSTALLATION AND OPERATION MANUAL READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS ...

Страница 2: ... it a more universal replacement cell for Hayward systems than the CaliMar CMARCHA15 2Y T CELL 3 equivalent 15 000 gallon capacity or the CaliMar CMARCHA25 2Y T CELL 9 equivalent 25 000 gallon capacity These cells can only be used in AquaRite systems with firmware revision 1 5 or newer or in AquaLogic systems with firmware revision 4 2 or newer The revisions took place in 2009 If any of the follow...

Страница 3: ...h the Diagnostic button until t xx shows on the display if t 15 is on the display skip the next step To change displayed cell type slide the main switch from Auto to Super Chlorinate and back to Auto repeating until t 15 is displayed o Push Diagnostic Button to exit For AquaRite Pro models o Access Settings Menu by pushing Settings button o Push until Chlor Config is displayed then push o Push rep...

Страница 4: ...0 hours per day adjust the chlorine output between 60 80 You can use this calculation to determine the appropriate chlorine output for your pool at the suggested 6 hours per day Pump running 24 hours a day x 25 chlorine output 6 hour cell run time per day at 25 Pump running 20 hours a day x 30 chlorine output 6 hour cell run time per day at 30 Pump running 15 hours a day x 40 chlorine output 6 hou...

Страница 5: ... 20 muriatic acid to clean the cell always add acid to the water If a cell cleaning stand is available fill the cell with the solution and let stand for about 10 minutes If not the solution can be poured into a bucket and the cell dipped into it taking care to avoid the acid contacting the cord harness c Rinse the cell with clean water and reattach to the plumbing line 3 If the Inspect Cell light ...

Страница 6: ...cident fire flood freezing lightning insects or other natural elements or other circumstances beyond the control of CaliMar Damage due to over tightening of threaded components or excessive pressure or stress Damage or premature wear due to improper pool chemistry and failure to maintain pool water chemistry in accordance with the recommendations contained in the owner s manual Damage due to impro...

Страница 7: ...7 CaliMar Pool Products USA Inc Manufacturers of Innovative Quality Pool Spa Products 888 635 0330 sales calimarpool com www calimarpool com ...