3
System Configuration
When replacing an existing T-CELL-15, GLX-CELL-15 or generic equivalent cell with the CMARCHA40-1Y, no system
reconfiguration is necessary. However, when using the CMARCHA40-1Y to replace a T-CELL-3 or T-CELL-9 (or a generic
equivalent), some adjustments may be necessary.
No reconfiguration is necessary for these models:
•
AQ-RITE (AquaRite
®
systems from 2008 and earlier – firmware older than version 1.5)
•
AQ-RITE-XL
Reconfiguring for other salt system models:
•
For AquaRite
®
models from 2009 or later, firmware version 1.5 or newer:
o
Slide the main switch to “Auto”
o
Push the Diagnostic button until “t-xx” shows on the display, if “t-15” is on the display, skip the next step
To change displayed cell type, slide the main switch from “Auto” to “Super Chlorinate” and back to
“Auto”, repeating until “t-15” is displayed
o
Push Diagnostic Button to exit
•
For AquaRite
®
Pro models:
o
Access Settings Menu by pushing “Settings” button
o
Push “>” until Chlor. Config. is displayed, then push “+”
o
Push “>” repeatedly until “Cell Type” is displayed
o
Push “+” or “-“ until “T-CELL-15” is displayed
o
Exit Settings Menu by pushing “Info” button
•
For all ProLogic
®
models:
o
Enter the Configuration Menu
o
Push “>” until Chlor. Config. is displayed, then push “+”
o
With Chlorinator enabled, push “>” repeatedly until “Cell Type” is displayed
o
Push “+” or “-“ until “T-CELL-15” is displayed
o
Exit Settings Menu by pushing Menu button