CF-8502_ii_190102
Pg 4
7
6
INSTALLING DRAIN
Slide white foam WASHER
(17)
up under flange of
BODY
(18)
- or -
Apply thin film of Silicon
®
sealant (or equivalent –
DO NOT use petroleum-based sealant as this WILL
void finish warranty) to underside of flange on
BODY
(18)
Insert BODY
(18)
down through sink drain hole
From underside, slide MACH-WASHER
(19)
and
FRICTION-WASHER
(19a)
up onto BODY
(18)
Secure BODY
(18)
into place with flange NUT
(20)
Apply Teflon
®
tape
(22)
(not supplied) to threaded
portion of TAILPIECE
(21)
& tighten onto BODY
(18)
INSTALLING SUPPLY LINES
IMPORTANT:
Prior to attachment, flush supply lines to remove
debris that may cause damage or malfunction to valve cartridge.
The following are two types of supply lines (not
included) that may be installed to the valve bodies:
Ballnose riser for exposed application
Install BALLNOSE RISER
(23a)
using valve NUT
(12c)
to secure riser to valve INLET
(12b)
Flexible riser for non-exposed application
Discard valve NUT
(12c)
& install FLEX RISER
(23b)
to valve INLET
(12b)
Final connections
Attach drain tailpiece to p-trap (not supplied)
Turn on water supply valves & check for leaks
californiafaucets.com
5271 Argosy Ave. Huntington Beach, CA 92649 800-822-8855
12b
23a
23b
12c
18
17
19
20
19a
22
21