CF-8502_ii_190102
Pg 2
2
3
INSTALLING VALVE
From underneath insert VALVE
(12)
though
appropriate sink/deck hole
IMPORTANT:
VALVES
(12)
are labeled as follows:
BLUE
is
COLD
left turning (counter-clockwise) closed
RED
is
HOT
right-turning (clockwise) closed
Position flange NUT
(10)
, WASHER
(9)
, and
SPACER
(11)
so that VALVE
(12)
extends
1-1/2”
above sink/deck surface
Attach INVERTED NUT
(13)
to VALVE
(12)
Use HANDLE
(15)
to confirm proper VALVE
(12)
alignment, rotate VALVE
(12)
if necessary
NOTE:
See image in Section 4 to confirm proper alignment of other
handles
INSTALLING ESCUTCHEON
NOTE:
Confirm orientation of RISER
(14c)
; hash marks at bottom as
shown
Insert O-RING
(14f)
into handle BASE
(14e)
, place
COINED RING
(14d)
on handle BASE
(14e)
,
position handle RISER
(14c)
on COINED RING
(14d)
, fit WASHER
(14b)
to ESCUTCHEON
(14a)
, place ESCUTCHEON
(14a)
onto RISER
(14c)
Place ESCUTCHEON ASSEMBLY
(14)
onto VALVE
(12)
and secure to sink/deck surface by tightening
ESCUTCHEON
(14a)
Use a ruler or straight edge to align the spout base,
and handle bases of the faucet as shown
After alignment retighten ESCUTCHEON
(14a)
and spout NUT
(6)
NOTE:
Return to Section 2 if valve is not aligned properly
1-1/2"
13
9
12
11
10
15
12
14a
14b
14c
14d
14e
14f
12