background image

11

Customer Support: 1-866-409-4581

AIR COMPRESSOR

test run

before using the air compressor for the first time.

Complete a test run as follows:

1.

Turn the power switch to the OFF position.

Plug the power supply cord into a power supply socket.

Start the air compressor by turning the power switch to the ON

position.

The pressure gauge reading will slowly rise as pressure

increases inside the air tank.

When the gauge reading reaches  120 PSI - 125 PSI, the

pressure switch will automatically turn the power off.

This indicates the compressor is working normally. 

2.

daily operation

Starting the compressor:

1.

Turn the power switch to the OFF position.

2.

Attach the air hose or air fitting to the 3/8” port located on the

regulator.

3.

Check that all air fitting are tight and close manual drain valve. 

4.  have air filters attached

5.

Plug the power supply cord into a 15amp (outlet) socket.

6.

Turn the power switch to the ON position.

7.

Let the motor run and tank fill until motor turns off.

8.  

To regulate the air flow. 

While the air compressor is running, turn “On” your tool and 
turn the regulator knob to the right increasing the pressure. 
Turn the pressure up until the desired pressure is reached.

9.  

Operate air tool normally. 

do not use continously (running) for more than (1) hour.

Shutting down the compressor:

1.

Turn the power switch to the OFF position.

2.

unplug the power supply cord.

3.

Reduce the pressure and drain the moisture from the air tank

by manually opening the ball drain valve.

Air compressor surfaces become hot during 
operation.

DO NOT touch hot surfaces, because they can cause 
severe burns.

Do not touch the air compressor’s cylinder head. 
During operation, the cooling fins of the cylinder 
head and delivery pipe become hot.

Allow the air compressor to cool before touching it.

DO NOT place a storage cover on the unit during 
operation. Only place a cover on the air compressor 
after it has thoroughly cooled down.

FIRE

HOT SURFACE

WARNING

Flying objects can cause injury to the eyes, head and 
other parts of the body.

Air-powered equipment and power tools are capable 
of propelling items (metal chips, fasteners and 
particulates) at high speed into the air and could 
result in injury.

Always wear approved head and eye protection.

Never point the air stream at any part of your body, 
or at another person or animal.

When operating the air compressor, make sure all 
other people and animals maintain a safe distance.

Do not move the air compressor when the air tank is 
under pressure. 

Never use the air hoses to pull or move the air 
compressor.

Keep the air compressor on a flat surface.

WARNING

FLYING OBJECTS

note: 

If the Air Compressor is not working properly, the

pressure gauge will indicate that there is a decrease in

pressure in the air tank. If there is an air leak from the

compressor the pressure in the air tank decreases, the

pressure switch resets and the motor automatically turns

back on.
If you detect an air leakage, turn the power switch to the

Off position, release the air from the tank by pulling on

the safety valve. unplug the power supply cord and contact

Customer Support for Assistance.

Turn the power switch to the Off position, unplug the power

supply cord and release the air in the  tank by pulling on the

safety valve. At this point proceed to the next step (daily

operations).

Содержание 30020DCADC

Страница 1: ... FREE AIR COMPRESSOR OwnER S MAnUAL CALIFORnIA AIR TOOLS 30020dCAdC 2 0 HP 6 40 CFM 40 PSI 5 30 CFM 90 PSI 30 gALLOn STEEL TAnk AIR dRyIng SySTEM AUTOMATIC dRAIn vALvE WWW CALIFORNIAAIRTOOLS COM Customer Support 1 866 409 4581 ...

Страница 2: ..._________________12 draining the air tank ___________________________12 changing the air filter__________________________12 testing for Leaks ______________________________12 pressure Switch _______________________________12 cleaning _____________________________________12 Storage______________________________________12 troubLeShootIng ____________________________13 SpecIfIcatIonS_________________...

Страница 3: ...OOLS COM please provide the information below Model number and Serial number and specifications shown on the Model number Serial number plate Part number or numbers shown in the parts list section of the owner s manual for your air compressor model A brief description of the trouble with the air compressor do not return your air compressor for service or parts to the store dealer where purchased I...

Страница 4: ... the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to the eyes head and other parts of the body Air powered equipment and power tools are capable of propelling items metal chips fasteners and particulates at high speed into the air and could result in injury Always wear approved head and eye protection Never point the air stream at any ...

Страница 5: ...chments Never make adjustments to the factory set pressures Never exceed manufacturer s maximum allowable pressure rating attachments Because of extreme heat do not use plastic pipe or lead tin solder joints for a discharge line WARNING EXPLOSION Use caution to minimize risk of fire or explosion It is normal for the air compressor motor and pressure switch to produce sparks while operating If spar...

Страница 6: ...se labels provide important safety and maintenance information These labels should be considered as permanent parts of the air compressor Should any of these labels become illegible damaged or removed please contact California Air Tools Customer Service department at 1 866 409 4581 for replacements PROduCT LAbeL a b c d e f g h ...

Страница 7: ...7 Customer Support 1 866 409 4581 AIR COMPRESSOR ...

Страница 8: ...e desiccant captures and removes the moisture from the air air drying canister desiccant After 2 years of use the Canister desiccant needs to be replaced unscrew the canister with the tool provided with the replacement canister Remove the old desiccant discard and add new desiccant assembly Install the air filter 1 Attach the air filters to the top front side of motor head looking from the front t...

Страница 9: ...t or particulates are in the air This will damage the motor and impair proper operation Important Always use the air filter properly installed Use caution to minimize risk of fire or explosion It is normal for the air compressor motor and pressure switch to produce sparks while operating If sparks come in contact with vapors from gasoline or solvents they may ignite and cause a fire or explosion A...

Страница 10: ...auge use only a 3 wire extension cord that has a 3 blade grounding plug OPeRATINg The AIR COMPReSSOR Save this manual for future reference Introduction This air compressor features a compact structure stable performance a high airflow rate easy operation and maintenance because the air compressor produces no oil in the airflow it can be used as an independent air supply machine for situations in w...

Страница 11: ... surfaces because they can cause severe burns Do not touch the air compressor s cylinder head During operation the cooling fins of the cylinder head and delivery pipe become hot Allow the air compressor to cool before touching it DO NOT place a storage cover on the unit during operation Only place a cover on the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying obj...

Страница 12: ...with a new air filter testing for Leaks Make sure all connections are tight do not overtightly A small leak in any hose or pipe connection will reduce the air compressor s performance To test for small leaks spray a small amount of soapy water on the area suspected of leaking If the soap bubbles replace the broken part cleaning Clean items with a soft brush or wipe with a moistened cloth using a b...

Страница 13: ...or windings are burned out Contact Customer Support The motor does not start and makes a humming noise Capacitor is burned out Contact Customer Support The motor does not start or starts slowly Low voltage supply to the motor Check that the main voltage corresponds to the air compressor specifications An extension cord that is too thin or too long can cause a voltage drop use heavy duty extension ...

Страница 14: ...arth wire Green Red cords for Capacitor Electric cord for motor Solenoid valve Electric cord for motor Pressure switch Overload protector MAX temperature 135 C Pressure switch Safety valve Pressure gauge Regulator Pressure gauge Ball valve Filter Drain valve Air intake Check valve Solenoid valve Compressor Tank ...

Страница 15: ... legal rights and you may also have other rights which may vary from state to state disclaimer of other Warranties To the fullest extent permitted by applicable law this limited warranty is exclusive and expressly in lieu of any and all other warranties including without limitation any implied warranties of merchantability or fitness for a particular purpose or any other implied warranties that ma...

Страница 16: ...cation of these exclusions will be determined at the sole discretion of California Air Tools Inc registration Warranty registration with California Air Tools Inc is required on all products you can mail the enclosed registration form or register on line at www californiaairtools com Click on the Customer Service Tab and the Product Registration Tab how to Videos California Air Tools provides hOW T...

Страница 17: ...ormation date of Purchase ____________________________________________________________ MM dd yeuky Model Number ______________________________________________________________________________ Serial Number ___________________________________________________________ Found on name plate Purchased Location __________________________________________________________________________ Purchase Price ______...

Отзывы: