CALIFORNIA ACCENT LIGHTING, INC.
2034 E. Lincoln Ave. #431, Anaheim, CA 92806
ph. 800.921.CALI (2254) or 714.535-7900 \ fx. 714.535.7902
[email protected] \ calilighting.com
© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specifications without prior notice.
Installation Instructions
Overview
market
LITE
™
ML
2000-CM
1 of 11
Socket Detail
8.5”
6.5”
4.25”
Strain Relief Aircraft Cable
(Included)
Strain Relief Aircraft Cable
(Included)
Mounting Aircraft Cable
(Not Included)
Specify Length
Specify Spacing
Power Plug
(#ML2000-PP)
LED Lamp
(Included)
Black Medium Base Socket
(Included)
Canopy Mesh
(Included)
End Cap
(#ML2000-EC)
Aircraft Hook
(Included)
Strain Relief
Aircraft Cable
(Included)
12 Gauge Stranded
Black Conductor
IMPORTANT
VERIFY CORRECT
LUMINAIRE WAS RECEIVED WITH
CORRECT COLOR TEMPERATURE AND
VOLTAGE. MUST INSTALL FACTORY
PROVIDED END CAPS. REVIEW
INSTALLATION INSTRUCTIONS
BEFORE CUTTING OR INSTALLING.
CALI
WILL NOT BE RESPONSIBLE IF
INCORRECT LUMINAIRE IS INSTALLED.
• Electric compound miter saw
• 14.4 to 28 volt cordless drill
• Drill bits - concrete or wood
• Electrical cords
• Safety glasses
• Marker
• Electric hammer drill (optional)
• Phillips bits - sufficient quantity
• Electrical three ways
• Measuring tape
• Chalk line
• Sharp scissors
• Soldering iron with kit
PRODUCT INFORMATION
• For accent, decorative, ambient lighting
• 120V AC system for fast and easy installation
• Long life, energy efficient LEDs
• Maximum run: 250 ft
• Can be ordered to specific lengths for easier installation when exact
dimensions are known (Example: 10x10’ 6”)
• Plug and light system
• Lead wires are typically 6’ long
• UV rated with SunLight resistance
• Outdoor and indoor rated
• Wire ratings: 12/2 gage wire 300V 105° C UL Listed
105° C 300V VW-2 outdoor rated
ELECTRICAL
• Standard LEDs available in 1W or 3W. See brochure for details
• Maximum watts per run: 600W at 120V based on 5 amps
INSTALLATION TOOLS REQUIRED
INSTALLATION RECOMMENDATIONS
• Determine weight of marketLITE that will be used
• Determine length of marketLITE and multiply by weight
• An engineer must choose the proper aircraft cable to handle the tension,
based on length and weight to prevent product from sagging
• An engineer must determine the strength of the structure where the
cable will attach, based on tension calculation from previous step
• If installing on a pole, check with pole manufacturer to confirm the pole
can handle the tension
• marketLITE is hung to the above aircraft cable using the hooks. Secure
hooks to aircraft cable by crimping or using stainless steel tie wrap
• The supplied aircraft cable is designed to prevent strain on the wire
An additional aircraft cable is required to hang marketLITE