background image

CALIFORNIA ACCENT LIGHTING, INC.

2034 E. Lincoln Ave. #431, Anaheim, CA 92806

ph. 800.921.CALI (2254) or 714.535-7900  \  fx. 714.535.7902

[email protected]  \  calilighting.com

© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specifications without prior notice.

Installation Instructions

lip

LEDs

LLED

8350-UC

5 of 11

Wiring Diagram

RGB Controller

Front View

RGB Controller

(#DMX-RGB-128C)

Install Nicolaudie Easy Standalone Software

https://www.nicolaudie.com/en/esa.htm

Program DMX-RGB-128C Scene Setup

Scene number 

 

Red

 

Blue

 

Green 

 

Color temperature program 

 

Scene-0

   

162

 

182

 

255

 

White

 

Set Dimming Options:

- Select loop option

- Select fade option

- Set values at fade time 00m01500

- Set values at hold time 00m01500

- Set value dimmer 100

LLED8350

Detail C

Detail B

Detail A

AC Adapter

Input 100-240VAC

Plug in

Plug in

Back

Wall Controller

(Not Included)

Front

DMX-CT-5A

(Included)

Output
24VDC

Input

120V-277V

AC

Detail C

Switch 1 must be facing down

1 2 3

6

8 9 10

7

5

4

Detail B

DMX Signal Input

1

2

3

4

5

6

7

8

DMX (+)

White / Orange (Pin 1)

Orange (Pin 2)

White / Brown (Pin 7)

Brown (Pin 8)

DMX (-)

DMX (Ground)

Detail A

Plug in

TRA150-E-UNV-24VDC-10V

LLED8350

Detail C

Detail B

Detail A

AC Adapter

Input 100-240VAC

Plug in

Plug in

Back

Wall Controller

(Not Included)

Front

DMX-CT-5A

(Included)

Output
24VDC

Input

120V-277V

AC

Detail C

Switch 1 must be facing down

1 2 3

6

8 9 10

7

5

4

Detail B

DMX Signal Input

1

2

3

4

5

6

7

8

DMX (+)

White / Orange (Pin 1)

Orange (Pin 2)

White / Brown (Pin 7)

Brown (Pin 8)

DMX (-)

DMX (Ground)

Detail A

Plug in

TRA150-E-UNV-24VDC-10V

LLED8350

Detail C

Detail B

Detail A

AC Adapter

Input 100-240VAC

Plug in

Plug in

Back

Wall Controller

(Not Included)

Front

DMX-CT-5A

(Included)

Output
24VDC

Input

120V-277V

AC

Detail C

Switch 1 must be facing down

1 2 3

6

8 9 10

7

5

4

Detail B

DMX Signal Input

1

2

3

4

5

6

7

8

DMX (+)

White / Orange (Pin 1)

Orange (Pin 2)

White / Brown (Pin 7)

Brown (Pin 8)

DMX (-)

DMX (Ground)

Detail A

Plug in

TRA150-E-UNV-24VDC-10V

Содержание lipLEDs LLED8350-UC

Страница 1: ...2 3 9 or 6 5 6 5 2 increments up to max run 0 125 cutting tolerance See max run for more information 2 8 Maximum extrusion and lens length 8 Maximum extrusion and lens length Dry Location field cuttab...

Страница 2: ...t periodically Do not submerge lipLEDs in liquid Do not mount lipLEDs with staples nails or like means that might damage the insulation Mount with double sided tape and mounting clips Do not install l...

Страница 3: ...ashion Do not install mounting clip over LED diode Do not penetrate lightstrip with any foreign object Do not apply excessive pressure to surface of lightstrip or LEDs Do not fold crease or twist ligh...

Страница 4: ...g PACKAGE 140x135x50 365g USE Environment IP20 Temperature 0 C to 50 C AVAILABLE MEMORY CHANNELS STEPS 8 1691 16 1011 32 557 48 383 64 291 80 233 96 195 112 166 128 145 2 36 39 3 38 3 38 3 38 3 38 36...

Страница 5: ...t DMX CT 5A Included Output 24VDC Input 120V 277V AC Detail C Switch 1 must be facing down 1 2 3 6 8 9 10 7 5 4 Detail B DMX Signal Input 1 2 3 4 5 6 7 8 DMX White Orange Pin 1 Orange Pin 2 White Brow...

Страница 6: ...on on one end applies pressure to LLED8350 securing it to surface LLED8350 UC REQUIRES A TEAM EFFORT TO ENSURE SECURE AND CORRECT INSTALLATION Another person unreels LLED8350 from spool holding lights...

Страница 7: ...stallation 3 Lay mounting clips and pre drill using proper drill bit for surface and screw size RECOMMENDATION 8 32 X 1 screw 4 Screw mounting clip to surface then snap extrusion into mounting clips 2...

Страница 8: ...ity test 7 Set voltmeter to DC voltage then test power source before connecting 8 Connect power source to power connector TIP If LEDs do not turn on flip polarity or power source connection to power c...

Страница 9: ...t will Burn the transformer bobbin Burn the thermal or magnetic breaker Burn the primary or secondary wires due to high amperage caused by overload and or short circuit in line which will not allow th...

Страница 10: ...in any liquid Do not leave any exposed wires Do not cover transformer without proper ventilation Do not install damaged transformer WIRE SIZE VOLTAGE 40 VA 80 VA 120 VA 160 VA 200 VA 240 VA 260 VA 28...

Страница 11: ...lycarbonate lamps and mounting bases which may be under stress in their normal applications COMPATIBLE WITH POLYCARBONATE Mild soap and water Mineral Spirits Isobutyl alcohol VM and P Naphtha Varsol N...

Отзывы: