LP GAS HOOK UP (TYPE 1 OR QCC1 REGULATOR):

Grills orificed for use with LP gas come equipped with a high capacity hose/regulator assem bly for connection to

a standard 20 lb. LP cylinder (Type 1). The LP tank is not included.

Connection:

1/2” NPT male with a 3/8” Flare adapter (included). LP Hose with a quick disconnect and fittings are

included. Operating pressure: 11.0” W.C.

      CAUTION!

Before connecting LP tank to regulator, check that all grill burners and side burners, smokers, and rotisserie valves

are in the OFF position and open grill lid.

To connect the LP regulator/hose assembly to the tank/valve assembly, first make sure the main valve on the tank is  

completely closed. Although the flow of gas is stopped when the Type 1 system is disconnected as part of of its safety  

feature, you should always turn off the LP tank main valve after each use and during transport of the tank or unit. Insert 

the regulator inlet into the tank valve and turn to the black coupler clockwise until the coupler tightens up. Do not over-

tighten the coupler. Turn the main tank valve on and turn the burner control valves on the unit to the “HI” position for 

about 20 seconds to allow the air in the system to purge, turn valves off and wait 5 minutes before attempting to light the 

burners.

To disconnect the coupler, first make sure the main tank valve is turned off. Grasp the coupler and turn counter clock-

wise. The inlet will then disengage. Remove the inlet from the tank valve opening if it has not already done so when it 

disengaged. Your local LP filling station should be equipped with the proper equipment to fill your tank.

LP TANK REQUIREMENTS:

A dented or rusty LP tank may be hazardous and should be checked by your LP supplier. The cylinder that is used must 

have a collar to protect the cylinder valve. Never use a cylinder with a damaged valve. Always check for leaks after ev-

ery LP tank change. The LP gas cylinder must be constructed and marked in accordance with the specifications for LP 

gas cylinders of the U.S. Department of Transportation (DOT or CAN/CSA-B339) and designed for use with a Type 

1 system only. Do not change the regulator/hose assembly from that supplied with the unit or attempt to use a Type 1 

equipped regulator/hose assembly with a standard 510 POL tank/valve assembly. The cylinder must be provided with 

a shut-off valve terminating in an LP gas supply cylinder valve outlet specified, as applicable, for connection Type 1. If 

the appliance is stored indoors, the cylinder must be disconnected and removed from the appliance. Cylinders must be 

stored outdoors in a well-ventilated area out of the reach of children.

Note:

When an LP unit is being directly connected to an LP house  

system, you must follow the natural gas hook up guidelines.

The installer must provide the proper gas regulator to reduce  

the gas flow to 11” W.C.

Note:

The Grill comes with the LP Regulator/Hose assembly installed  

at the factory. The assembly, along with the entire Grill system,  

is leak tested. Do not remove the Regulator/Hose assembly  

from the Grill during installation.

      WARNING

:

 

»

Do not remove the Grill from the pallet until you are 

ready to install.

 

»

Do not place the Grill directly on the ground or any other 

flat surface without support. This will prevent damaging 

the regulator/hose assembly by the weight of the grill.

 

»

Check the hose, regulator and connectors for damage. 

Look for cracks, abrasions, brittleness, holes, dents and nicks.

 

»

Do not attempt to remove, repair, or replace the Regulator/ 

Hose assembly by yourself. It must be done by a 

qualified licensed technician only.

*Installation must conform with local codes or with 

the National Fuel Gas Code ANSi Z223.1 or the 

CAN/CGA-B149.2 Propane Installation Code

Type 1 Regulator

LP Regulator hose 

assembly 11” W.C.

20 lb LP Tank

Main Tank Valve

1/2” female NPT from unit 

connection to 3/8” male 

flare of  L.P. hose assy

Bottom of unit

Содержание Crossflame Silver Series

Страница 1: ...ss steel finish Add suffix C for cart mounted units 41 3 BURNER GRILLS CGA41 2G 1SR L N 2 grill burners 1 sear burner w rotis w stainless steel finish CGA41 2G 1S L N 2 grill burners 1 sear burner no...

Страница 2: ...ge 19 Page 20 Page 21 22 Pages 23 24 Care and Safety Precautions Grill Placement and Installation Pressure Testing and Hookups Leak Testing Air Shutter Adjustments Lighting Match Lighting Instructions...

Страница 3: ...inding a leak is not a do it yourself procedure Some leaks can only be found with the burner control in the ON position and this must be done by a qualified technician Never attach or disconnect an LP...

Страница 4: ...y prac tices must be followed including but not restricted to the following FIRST Read entire Use and Care Manual carefully and completely BEFORE using your grill for the first time to reduce the risk...

Страница 5: ...e sure all grill controls are turned off and the grill is cool before using a type of aerosol cleaner on or around the grill The chemical that produces the spraying action could in the presence of hea...

Страница 6: ...ners keep the ports clean It is necessary to clean periodically for optimum performance Clean the grill with caution Avoid steam burns do not use a wet sponge or cloth to clean the grill while it is h...

Страница 7: ...operate this unit according to the Use and Care Guide ensuring you provide good ventilation when cooking with gas This outdoor cooking gas appliance is not intended to be installed in or on recreatio...

Страница 8: ...from blowing at someone who is cooking on the grill If you have to locate the grill in a windy area where the prevailing wind is at the rear of the grill a windbreak must be installed The windbreak s...

Страница 9: ...EFINITION OF NONCOMBUSTIBLE MATERIAL Material which is not capable of being ignited and burned such as materials consisting entirely of or a combination of steel iron brick tile concrete slate and pla...

Страница 10: ...the back of enclosure Figs below in order to safely dissipate unburned gas vapors in the event of a gas supply leak WARNING Note specific built in enclosure ventilation requirements See text and illus...

Страница 11: ...5 kPa The installation of this appliance must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 Installation in Canada must be in accordance with th...

Страница 12: ...ve Always check for leaks after ev ery LP tank change The LP gas cylinder must be constructed and marked in accordance with the specifications for LP gas cylinders of the U S Department of Transportat...

Страница 13: ...ustrate how to properly locate and install the LP tank restraint within the Built in enclosure NOTE The grill comes with the LP Regulator Hose assembly installed at the factory The assembly along with...

Страница 14: ...d on male thread only Do not use threading com pound on the male end of 1 2 NPT to 3 8 flare adaptor Use second pipe wrench to hold the grill inlet pipe to avoid shifting any internal gas lines of the...

Страница 15: ...ion type QCC 1 in the standard for compressed gas cylinder valve outlet and inlet connec tion ANSI CGA V 1 NOTE The LP Tank is NOT INCLUDED with the grill and must be purchased separately from your lo...

Страница 16: ...he grill until all connections have been checked and DO NOT leak Make sure all control valves are in the OFF position Turn the gas supply ON Check all connections from the supply line or LP cylinder u...

Страница 17: ...Leak test points LP Gas Nat Gas Check all gas supply fittings for leaks before each use Leak test point LP tank NG safety shut off valve Leak test points Leak test points Leak test points Leak test po...

Страница 18: ...he burner Loosen the lock screw of the air shutter Make certain that the burners are sitting properly around the orifices and then light the burners WARNING If the burner is not sitting around the ori...

Страница 19: ...as been replaced that there may be air in the gas line that needs to be purged so the push and turn to HI may need to be repeated several time to purge the line of air PRE LIGHTING CHECKLIST Ensure th...

Страница 20: ...not light within 4 seconds turn the knob to the OFF position and wait 5 minutes before attempting to light the burner again Below To match Light the rear Rotisserie burner on equipped models NOTE The...

Страница 21: ...tor and bracket from protective wrapping Remove nuts and screws on bracket and insert screws on bracket and insert screws with bracket attached into holes on left side of the grill body Replace nuts a...

Страница 22: ...e GRILL BURNERS Frequency of cleaning will depend upon how often you use the grill Ensure that the gas supply is OFF and all knobs are in the OFF position Extreme care should be used when removing any...

Страница 23: ...ons where the product is used extensively Caliber will at its option repair or replace any defective part with the owner paying for all other costs including freight and labor WARRANTY DEFINITIONS LIM...

Страница 24: ...and dealer name model and serial number of the grill date of purchase and an accurate description of the problem Caliber will not pay for service calls for correcting an improper installation or for...

Страница 25: ...truction combustible verticale adjacent d passant la partie sup rieure de l appareil soit _ pouces des c t s et _ pouces de l arri re Il est interdit d installer le pr sent appareil au dessous des sur...

Страница 26: ...rds de l aapareil ne fuient pas Pour allumer l appareil suivre les instructions du manufacturier Lorsqu on ne se sert pas de l appareil maintenir le robinet de la bouteille ferm N enlevez pas ne d t r...

Страница 27: ......

Страница 28: ...pecifications All material contained herein may not be reproduced without prior written consent of Caliber Appliances Copyright 2017 CALIBERAPPLIANCES COM Caliber Appliances 17812 Metzler Lane Hunting...

Отзывы: