Inspection
Inspect packages for damage. If damaged, notify the appropriate carrier immediately. If
undamaged, open the package and inspect the device for obvious damage. Return damaged
products.
•
Use only copper conductor supply wire suitable for at least 105° C
•
All circuits must have a common disconnect and be connected to the same pole of the disconnect
Maintenance and Repair
The Caleffi Z-one
™
switching relay box contains a spare fuse and requires no maintenance. If
any product fails or is damaged, replace product with functional one.
Mounting
Mount the Caleffi Z-one
™
switching relay box to a suitable surface. Slotted holes are provided
for mounting purposes. Do not mount to a surface that exceeds 115°F (45°C). The unit must be
only located in dry interior locations. It is not suitable for installation in hazardous locations and
should not be placed close to any electromagnetic fields.
Installation
•
Remove cover of relay box.
•
Identify the four mounting
holes on relay box, mark on
the wall the desired location of
mounting.
•
Drill, anchor, and fasten four
screws for mounting.
•
Hang relay box and fasten tight
to desired locations.
•
Complete wiring connections
in accordance with terminal
locations.
•
Place cover back on relay box.