background image

D

B

E

A

A

A

D

B

E

A

A

D

B

E

A

F

G

F

B

A

D

E

F

F

A

D

B

E

F

A

G

F

B

A

D

E

T

max

 250 F

P

max

150 psi

T

max

 220 F

P

max

 150 psi

BI-DIRECTIONAL

38466.01

T

max

 250 F

P

max

150 psi

T

max

 220 F

P

max

150 psi

BI-DIRECTIONAL

38466.01

A

A

D

E

C

C

C

C

C

C

C

B

G

A

D

B

E

A

F

C

* Add suffix C to sweat and NPT code number when ordering the brass 

DISCAL to ship with expansion tank service check valve, code 561402A.

1/2”

E

C

B

F

D

Code

A

B

C

D

E

F

Wt (lb)

5517

05A

3

4

" NPT

5

1

8

"

2

3

16

"

5

3

8

"

9

1

4

" 3

1

2

"

4.9

5517

65A

3

4

" press

6

3

8

"

2

3

16

"

5

3

8

"

9

3

4

” 3

1

2

"

4.9

5517

95A

3

4

" SWT

6"

2

3

16

"

5

3

8

" 9

3

16

” 3

1

2

"

4.9

5517

06A

1" NPT

6

3

4

"

2

3

16

"

5

3

8

"

9

3

4

” 3

1

2

"

4.9

5517

66A

1" press

6

3

4

"

2

3

16

"

5

3

8

"

9

3

4

” 3

1

2

"

4.9

5517

96A

1" SWT

7"

2

3

16

"

5

3

8

"

9

3

4

” 3

1

2

"

4.9

5517

16*

--

3

3

4

2

3

16

"

5

3

8

"

9

1

4

" 3

1

2

"

4.4

* Body only, no end connection fittings. Source separately, see Caleffi 

catalog for end connection code numbers.

Code

A

Lay length

5517

65A

3

4

" press

5

8

"

5517

66A

1" press

3

4

"

Dimensions

Code

A

B

C

D

E

F

Wt (lb)

551

003A*

3

4

" NPT

3

1

16

"

2

3

16

"

5

3

8

" 6

7

8

"

1

2

"

2.0

551

022A*

3

4

" SWT

3

1

16

"

2

3

16

"

5

3

8

" 6

7

8

"

1

2

"

2.0

4

Содержание DISCAL 5517 Series

Страница 1: ...k valve AC with service check 551 series DISCAL air separator for horizontal pipes in brass with drain Sizes 1 1 1 2 NPT female 1 1 1 2 integral sweat A without service check valve AC with service che...

Страница 2: ...es and 1 sweat press and NPT male union lay length press connection see page 4 and 5 drain 1 2 NPT female 5517 series 1 2 straight female Steel air separator Materials body epoxy resin painted steel i...

Страница 3: ...his manual for the user SAFETY INSTRUCTION This safety alert symbol will be used in this manual to draw attention to safety related instructions When used the safety alert symbol means ATTENTION BECOM...

Страница 4: ...53 8 93 4 31 2 4 9 551795A 3 4 SWT 6 23 16 53 8 93 16 31 2 4 9 551706A 1 NPT 63 4 23 16 53 8 93 4 31 2 4 9 551766A 1 press 63 4 23 16 53 8 93 4 31 2 4 9 551796A 1 SWT 7 23 16 53 8 93 4 31 2 4 9 551716...

Страница 5: ...16 69 16 81 4 1 2 4 9 551008A 11 2 NPT 47 8 23 16 69 16 81 4 1 2 4 9 551009A 2 NPT 51 8 23 16 69 16 81 4 1 2 5 5 551028A 1 SWT 51 16 23 16 53 4 71 2 1 2 3 7 551035A 11 4 SWT 53 16 23 16 65 16 81 4 1...

Страница 6: ...minimum of 3 wall clearance to accommodate insulation if used Code A B C D E F G H J Wt lb 551050A 2 133 4 1 143 4 1915 16 65 8 213 16 6 65 16 34 551060A 21 2 133 4 1 143 4 1915 16 65 8 213 16 7 65 16...

Страница 7: ...8 1 2 20 32 1 2 56 335 NA551250A 10 41 3 4 26 8 1 2 22 5 8 38 1 4 110 617 NA551300A 12 46 1 2 30 8 1 2 25 3 8 43 3 8 169 871 These models are ASME tagged and registered with the National Board of Boi...

Страница 8: ...0 4 0 025 0 03 0 02 6 7 8 9 12 14 16 18 25 30 35 40 45 60 70 80 90 120 140 160 180 250 400 450 300 350 600 700 800 900 1 2 1 4 1 6 1 8 2 6 4 5 1 2 1 4 1 6 1 8 2 69 83 97 111 125 2000 1200 1400 1600 1...

Страница 9: ...i BI DIRECTIONAL 38466 01 T max 250 F P max 150 psi T max 220 F P max 150 psi BI DIRECTIONAL 38466 01 T max 250 F P max 150 psi T max 220 F P max 150 psi BI DIRECTIONAL 38466 01 T max 250 F P max 150...

Страница 10: ...g due to accumulating residue in the flowing fluids 6 5 5 3 4 4 3 6 5 4 59829 even when the DISCAL air separator is not installed perfectly vertical A replacement air vent assembly for the DISCAL bras...

Страница 11: ...6 5 5 3 4 4 3 6 4 4 4 11...

Страница 12: ...562100 Small anti vacuum vent cap 59119 Replacement DISCAL air vent cap 7 15 20 12 Insulation shells for brass DISCAL series for horizontal pipes These are not designed for the compact or 517 series r...

Отзывы: