background image

SATK20 & SATK30

9

Components - SATK20103 LOW Temperature HIU

Item Component

1

Frame

2

Electronic controller

3

Thermal safety relief valve

4

Heating mixing valve

5

DHW production modulating valve 

6

Heat flow temperature probe

7

Thermal safety thermostat

8

DHW temperature probe

9

DHW heat exchanger

10

Drain cock

11

UPS 15-60 pump

12

Protective pump by-pass

13

Flow temp. compensation return probe

14

DHW priority flow meter

15

Heat meter spool piece

16

Air vent cock

17

System strainer/heat meter flow probe pocket

18

Primary circuit isolating valve

Functional characteristics

Heating range: 

25 to 45˚C

Set point regulation

DHW production range:

42 to 60˚C

Optional functions

Domestic water cycle:

domestic water preheating function

Heating cycle:

modulating temperature regulation 
with compensated set point

floor slab heating function

Factory settings

Components - SATK20203 MEDIUM Temperature HIU

Item Component

1

Frame

2

Electronic controller

3

Heat mixing valve

4

DHW production modulating valve 

5

Heating flow temperature probe

6

DHW temperature probe

7

DHW heat exchanger

8

Drain cock

9

UPS 15-60 pump

10

Protective pump by-pass

11

DHW priority flow meter

12

Heat meter spool piece

13

Air vent cock

14

System strainer/heat meter flow probe pocket

15

Primary circuit isolating valve

Functional characteristics

Heating range:

50 to 75˚C

Set point regulation

DHW production range:

42 to 60˚C

Optional functions

Domestic water cycle:

domestic water preheating function

Factory settings

1

2

3

4

5

6

4

ON

10

11

12

13

14

15

1

2

3

4

6

7

5

9

8

1

2

3

4

5

6

4

ON

9

10

11

12

13

14

15

16

1

2

3

4

6

7

8

5

17

18

Содержание Altecnic SATK20

Страница 1: ...SATK20 SATK30 heat interface unit Installation Operation Maintenance Instructions...

Страница 2: ...roduct range 1 Safety instructions 1 Dimensions and technical speci cation 3 Installation 4 First operation 5 Electronic controller 6 Safety and alarms 7 SATK20103 and SATK20203 components 8 SATK20303...

Страница 3: ...e operation of the device and or system NOTE Risk of electric shock Live parts Shut off the electric supply before opening the HIU cover 1 During installation and maintenance operations always avoid d...

Страница 4: ...Dimensions SATK30 A B C kg G B G B G B 16 A B C kg G B G B G B 19 550 A A B B 65 65 450 C C 59 101 160 65 190 195 430 15 490 46 10 245 110 265 110 85 A A B B 629 65 65 550 C C 159 101 160 65 290 195 5...

Страница 5: ...changer brazed stainless steel Installation The SATK series HIUs are designed for installation in a sheltered domestic environment or similar therefore cannot be installed or used outdoors i e in area...

Страница 6: ...ent Connection to the main supply The device is supplied with an electric supply cable plug not supplied The device should be electrically connected to a 230 V ac single phase earth mains supply using...

Страница 7: ...e cover close the isolating valves empty the HIU using the drain cocks provided remove the spacer piece A remove the blanking plug B install the ow probe in the 1 4 pocket B provided install the ow me...

Страница 8: ...vated the circulation pump shuts down and the and the regulating valve closes Heating cycle activation is indicated by a ashing fault LED on the electronic controller This fault does not affect the ge...

Страница 9: ...d Safety valve fault Error code 76 SATK20103 LOW temperature Removing a fault Normal operating conditions are restored automatically once the faulty safety valve is working correctly again Safety sett...

Страница 10: ...tic water preheating function Heating cycle modulating temperature regulation with compensated set point floor slab heating function Factory settings Components SATK20203 MEDIUM Temperature HIU Item C...

Страница 11: ...ds the drying of the under oor heating screed at low temperatures This function can only be activated and executed if there are no faults It can be activated by pressing and holding the RESET button f...

Страница 12: ...al load under control The thermal response time of the system is thus minimised Safety and alarms Error codes associated with faults signalled by the lighting up of the FAULT LED are also shown on the...

Страница 13: ...The function is enabled by setting dip switch 5 to the ON position During periods when the domestic water cycle is not used if the DHW probe detects a temperature 10 C below the SET value the control...

Страница 14: ...eturn temperature sensor 22 Pressure gauge 23 Filling loop isolation valve 24 Filling loop double check valve 25 Filling loop Not shown on Components illustration Functional characteristics SATK30103...

Страница 15: ...rying of the under oor heating screed at low temperatures This function can only be activated and executed if there are no faults It can be activated by pressing and holding the RESET button for 8 sec...

Страница 16: ...l maintenance procedures should be carried out by an authorised technician Regular maintenance guarantees better ef ciency and helps to save energy Before carrying out any maintenance repair or part r...

Страница 17: ...the new probe Reconnect the connector respecting the only possible way it can be inserted When carrying out maintenance on the electrical system for the connections follow the diagram on page 16 Afte...

Страница 18: ...HW production valve actuator x x x x Thermal safety relief valve x x Thermal safety thermostat x x Heating flow temperature probe x x x x x x x x x x x x x x x Electric supply 230 V ac x x x x x x x x...

Страница 19: ...artly clogged call quali ed personnel to have it serviced modulating valve actuator faulty call quali ed personnel to have it replaced valve obturator blocked in intermediate position call quali ed pe...

Страница 20: ...valves terminals closed open the valves centralised system temperature insuf cient contact person in charge of system electronic controller not working call quali ed personnel to have it replaced prim...

Отзывы: