Description of symbols

Disposal

Signal words describe the danger that may occur, when it 
is not avoided.
Warning means that injury, possibly life-threatening injury, 
can occur.
Attention means that damage to the appliance can occur.

 

• Dispose of the packaging in an environmentally sound 

manner.

 

• Dispose of old appliances in an environmentally sound 

manner. Upon request we will take back your old 
 appliances bought from us and guarantee an environ-
mentally sound disposal of the devices.

Information about the product

Proper usage
The iSolar WMZ-G1 is to be used for the measurement 
and the display of system data by means of Grundfos Direct 
Sensors

™ 

in compliance with the technical data specified in 

this manual. 
Improper use excludes all liability claims.

Note
Notes are indicated with an information symbol.

Arrows indicate instruction steps that should be carried 
out.

Table of contents

General .......................................................................2
Instructions ................................................................2
Description of symbols .............................................2
Disposal ......................................................................2
Information about the product ................................2
Technical data and overview of functions ...............3
VBus board.................................................................4
1. 

Installation .....................................................5

1.1 

Mounting ........................................................5

1.2 

Connections ..................................................5

1.3 

Data communication / Bus ..........................5

2. 

Operation and function ................................6

2.1 

Push buttons for adjustment .......................6

2.2 

Menu structure .............................................7

2.3 

Initial commissioning ...................................7

2.4 

Operating control lamp ...............................7

3. 

Measured values ............................................7

4. 

Balance values ...............................................7

5. 

Adjustment values ........................................8

6. 

Reports ........................................................12

7. 

Examples of connection .............................15

Imprint .....................................................................16

WARNING!

Warnings are indicated with a 
warning triangle!

 

Î

They  contain  information 
on how to avoid the danger 
described.

Safety advice
Please pay attention to the following safety advice in order 
to avoid danger and damage to people and property.
Instructions
Attention must be paid to the valid local standards, regula-
tions and directives!
Equipment to be installed and used in accordance with the 
rules of the National Electrical Code (NEC) or with Cana-
dian Electrical Code (CEC), Part I.

Target group
These instructions are exclusively addressed to authorised 
skilled personnel.

 

• Only qualified electricians should carry out electrical 

works.

 

• Initial installation must be effected by qualified personnel 

named by the manufacturer.

General

Содержание iSolar Wmz-G1

Страница 1: ...G1 Mounting Connection Operation Manual 11200827 11200827 Thank you for buying this product Please read this manual carefully to get the best performance from this unit Please keep this manual careful...

Страница 2: ...2 Description of symbols 2 Disposal 2 Information about the product 2 Technical data and overview of functions 3 VBus board 4 1 Installation 5 1 1 Mounting 5 1 2 Connections 5 1 3 Data communication...

Страница 3: ...nding on the number and type of sensors connected the unit is capable to show temperature values flow rates and relative or differential pressures or a combination of them Heat quantity measurement is...

Страница 4: ...theVBus slave board When several iSolar WMZ G1 modules are cascaded and connected to a datalogger or PC see p 14 only theVBus master boards of the iSolar WMZ G1 modules with the subaddress 1 or higher...

Страница 5: ...l allocations Put the cover on the housing and attach with the cross head screw 1 Installation 1 2 Connections The power supply of the device must be carried out via an external power supply switch on...

Страница 6: ...to confirm the adjust ment Please reply to the following security inquiry Save by choosing yes or no buttons 1 and 2 and confirm with button 3 Note If button 3 is kept pressed for 2 seconds the displa...

Страница 7: ...e sensors connected is a VFS type sensor and the option Heatmeter in the submenu Adj values has previously been set to Yes S1 measures the flow temperature S2 the return temperature If the flow temper...

Страница 8: ...sensor 1 in l min m h gallon h Max maximum flow rate at sensor 1 in l min m h gallon h Acc accumulated volume since commissioning last re set in l m or gallons Display of balance values Sensor 2 Temp...

Страница 9: ...1 6 bar 0 2 5 bar 0 4 bar 0 6 bar 0 10 bar 0 16 bar 0 25 bar 0 40 bar DPS Range Custom Min 0 00 15 99 bar Max 0 00 16 00 bar 0 0 6 bar 0 1 bar 0 1 6 bar 0 2 5 bar 0 4 bar 0 6 bar 0 10 bar 0 16 bar Adj...

Страница 10: ...depends on the sensor type Therefore the following parameters and adjust ment values depend on the sensor type flow rate forVFS pressure for RPS differential pressure for DPS Adjust the parameters re...

Страница 11: ...has to be adjusted Adjustment range 0 99 9 bar Heat quantity measurement Heat quantity measurement is carried out by means of the difference between the flow and the return temperature as well as the...

Страница 12: ...Do not change the factory setting if the WMZ G1 is connected to a controller with VBus output terminal corresponds to the bus mode Passive Select bus mode Active if theWMZ is not connected to a contr...

Страница 13: ...arm Reports Sensor 1 Min d p alarm The differential pressure at sensor 1 has fallen below the adjusted minimum value Signal failure at sensor 1 signal 1 temperature Signal failure at sensor 1 signal 2...

Страница 14: ...2 Min d p alarm Signal failure at sensor 2 signal 1 temperature Signal failure at sensor 2 signal 2 this can be flow rate relative pressure or differential pressure depending on the sensor type The ad...

Страница 15: ...Yes iSolar WMZ G1 1 15 slave board subaddress 1 15 bus mode Cascaded The connection sequence at theVBus is arbitrary Cascade with controller controller No adjustments have to be made iSolar WMZ G1 mod...

Страница 16: ...ectronic systems Editor CALEFFI NORTH AMERICA Inc Important notice The texts and drawings in this manual are correct to the best of our knowledge As faults can never be excluded please note Your own c...

Отзывы: