Safety

· Tempering valves must only be installed by a licensed plumber.

· A minimum temperature differential of 10°C is required between the hot water inlet

and the mixed water outlet to ensure correct operation of the thermal shutoff feature.

· Water temperatures higher than 50°C can endanger people.

· Ensure that the valve is supported and that the connecting pipework is not overstressed as

breakages can cause harm to people and/or water damage to property.

· In the case of highly aggressive water, in accordance with the current legislation, treat the

water before it enters the tempering valve. This will avoid damage to the valve.

· If the tempering valve is not installed, commissioned and maintained properly, according to

the instructions contained in this manual, it may not operate correctly and may endanger the user.

Leave this manual for the user.

CALEFFI

S.R. 229, n. 25 · 28010 Fontaneto d’Agogna (NO) · Italy · Tel. Int. +39 322 8491 R.A. · Fax +39 322 863723

Http://www.caleffi.com · E-mail:[email protected]

AUSTRALIAN AGENT

All Valve Industries

Unit 2, 18-28 Sir Joseph Banks Drive

Kurnell NSW 2231

Ph: (02) 8543 9811

Fax: (02) 8543 9822

Email: [email protected]

Содержание 2522HP Series

Страница 1: ...meet the requirements of AS 4032 2 2005 Tempering valves and end ofline temperature actuated devices This particular series of tempering valves has been developed primarily for installation in solar h...

Страница 2: ...erature 55 C Maximum hot inlet temperature 100 C Maximum working pressure static 1400 kPa Maximum working pressure dynamic 500 kPa Minimum working pressure dynamic 20 kPa Maximum unbalanced dynamic su...

Страница 3: ...water entering the valve If there are variations of temperature or pressure at the inlets the internal element automatically reacts attempting to restore the original temperature setting Thermal shut...

Страница 4: ...er heater In order to maintain the set temperature the tempering valve must have a minimum flow rate of 4 l min When used in instantaneous hot water systems the most stable conditions are achieved wit...

Страница 5: ...5 8 7 4 1 2 6 9 1 CAP 3 4 7 9 8 5 6 3 2 VALVE BODY UNION NUT GASKET INSERT CHECK VALVE TAIL PIECE BODY INSERT STRAINER TEMPERATURE ADJUSTMENT SPINDLE LOCKING NUT Exploded diagram KIT A 5...

Страница 6: ...The hot and cold water supplies must be connected to the valve strictly in accordance with the indications on the body of the valve The inlets of the valves are clearly marked with the letter H Hot an...

Страница 7: ...lar system MAINS SUPPLY System without recirculation System with recirculation MAINS SUPPLY MAINS SUPPLY HOT WATER STORAGE HEATER HOT WATER STORAGE HEATER SOLAR HOT WATER STORAGE 7 Application diagram...

Страница 8: ...commissioned The temperature setting can be adjusted by removing the cap and rotating temperature adjustment spindle We suggest that the following sequence is followed when commissioning the valve a...

Страница 9: ...9 1 2 3 4 Temperature adjustment Remove the cap Direction of temperature adjustment Temperature adjustment Lock adjustment spindle with locking nut...

Страница 10: ...should be removed for cleaning by unscrewing the inlet union nuts and carefully pulling apart the connecting pipework B The built in check valves 7 can be accessed in a similar way to A Ensure freedom...

Страница 11: ...Starvation of the water supplies at the inlets of the valve c Incorrect commissioning of the valve a Insufficient water supplies b Fluctuations in supply pressures temperatures c Adverse effect create...

Страница 12: ...highly aggressive water in accordance with the current legislation treat the water before it enters the tempering valve This will avoid damage to the valve If the tempering valve is not installed comm...

Отзывы: