dON'T use a water clarifier; Clarifiers will cause the spa water to become cloudy.

• 

dON'T use the MONarCH silver cartridge with FrOG.

ChlORINE (SOdIUM dIChlOR) 

(uSE 

MONarCH

 CHlorinE)

A.  Sanitizing chemicals, such as chlorine, are oxidants that kill bacteria and viruses in the water. The Free Available Chlorine (FAC) is a 

measure of the amount of unused chlorine available to sanitize the spa. The recommended FAC for your spa water is 3.0-5.0 ppm.

B.   Watkins Manufacturing Corporation recommends the use of sodium dichlor type granulated chlorine for sanitizing the water. Sodium 

dichlor is preferred because it is totally soluble, dissolves quickly and is nearly pH neutral.

C.   Maintaining the proper level of chlorine during use is extremely important.
D.   If the FAC is too low, bacteria and viruses can grow rapidly in the warm water. Increase the FAC by adding granulated sodium 

dichlor.

E.   If the FAC is too high, the water can cause discomfort to the user’s eyes, lungs and skin. Simply allow some time to pass. The FAC 

level will drop naturally over time.
F.   When the Free Available Chlorine is within the recommended range, the spa is ready to be enjoyed.

SUPER ChlORINATION

Super Chlorination is a process used to eliminate chlorine smell (if you are using chlorine) by “burning-off” chloramines (used chlorine). This helps maintain the proper 

level of free chlorine.
When giving your water a super chlorination treatment, open the cover at least half way for twenty minutes to allow the chlorine gas to vent off. The high concentration 

of chlorine gas which may exist as a result of super chlorination (not daily sanitation) may eventually cause discoloration or degradation to the bottom of the cover, which 

would not be covered under the terms of your warranty.

WarNING

: There are several forms of stabilized chlorine available for use in spas and swimming pools.  Each form has specific chemical characteristics. It is 

extremely important that the form you choose is specifically designed for use in spas. Use of an incorrect product such as tri-chloro, which has a very low pH (2.6), 

dissolves too quickly in hot water resulting in extremely high levels of chlorine, and is designed for concrete or plaster swimming pools, WILL cause damage to your spa.  

Use of a liquid, or any type of compressed bromine or chlorine, acid, or any type or sanitizer which is not recommended by Watkins Manufacturing Corporation, WILL 

damage your spa and is specifically not covered under the terms of the limited warranty.

IMPOrTaNT: 

Granulated chlorine (sodium dichlor) will degrade if stored improperly. We recommend purchasing chlorine in one, two, or five pound containers and 

storing it in a cool, dry place to maintain its potency. 

WarNING

: Never leave an open spa unattended, especially if there are children present!

SUPPlEMENTAl wATER MAINTENANCE

Proper water sanitation and mineral balance (pH control) are absolutely essential for a complete spa water maintenance program. Here are two other popular water 

additives that are optional:

1.  Mineral deposit Inhibitors 

(uSE 

MONarCH

 STAin/SCAlE)

As water evaporates from your spa and new water is added, the amount of dissolved minerals will increase. (Minimize evaporation by keeping the cover on the spa 

whenever possible.) The spa water may eventually become “hard” (Calcium Hardness too high) enough to damage the heater by calcifying its surface. Proper pH control 

can minimize this.

WaTer QUalITY aNd MaINTeNaNCe

26

*

MONarCH

 MPS and MPS Plus is an oxidizer, not a sanitizer

WaTKINS 

 

WaTer TreaTMeNT GUIde

at spa startup or refill

Follow spa Start-Up and Refill Procedures.

Prior to each use

(Test before adding any chemicals; do not add any 

chemicals if proper or higher levels are found.)

Add one-half (½) teaspoon of 

MONarCH 

sodium dichlor per 

250 gallons,

 

Or

 Add one (1) tablespoon 

MONarCH

 MPS 

Plus (monopersulfate)* per 250 gallons

Once a week

Add one-half (½) teaspoon of 

MONarCH 

sodium dichlor 

per 250 gallons,

 

Or

 Add three (3) tablespoons 

MONarCH

 

MPS Plus (monopersulfate)* per 250 gallons

every four months

Drain and refill your spa.
Follow spa Start-Up and Refill Procedures.

as needed

(If water is hazy, cloudy or has an odor)

Add one and one half (1-1/2) teaspoons of sodium 

dichlor per 250-gallons, as needed.

Содержание vacanza series

Страница 1: ...VACANZA SERIES 2 0 1 4 O W N E R S M A N U A L...

Страница 2: ...SPA MODEL SERIAL NUMBER ____________________________ COVER SERIAL NUMBER ________________________________ In most cities and counties permits will be required for the installation of electrical circu...

Страница 3: ...ONS Control Operation 14 System Mode 15 Manual Clean Cycle 15 Tools Menu 15 Audio Menu Optional 17 Air Control 19 Hydrotherapy Jets 19 Waterfall Valve 19 WATER QUALITY AND MAINTENANCE Water Terminolog...

Страница 4: ...tion of this important safety device test according to the following instructions per electrical configuration Cord Connected 115 volt 20 amp models The GFCI is located at the end of the power cord Be...

Страница 5: ...ion fitting There is a danger of slipping and falling Remember that wet surfaces can be very slippery Take care when entering or exiting the spa Never operate spa if the suction fittings are broken or...

Страница 6: ...the control box by the spa owner will void the warranty If you have an operational problem carefully go through the steps outlined in the Troubleshooting section If you are not able to resolve the pro...

Страница 7: ...manual and printed instructions on all water care chemical products packaging Test the water regularly to ensure proper levels of sanitizers pH and other water care requirements Drain clean and refil...

Страница 8: ...he spa s safety features Improper wiring may also cause electrocution risk of fire and other risks of injuries Please read and follow the electrical installation requirements and instructions for your...

Страница 9: ...to the wiring diagram below 1 Connect the 8 AWG WHITE NEUTRAL wire from the Neutral Ground Bar on the main electrical service to the WHITE NEUTRAL Panel Neutral Pigtail of the subpanel 2 Connect the...

Страница 10: ...ALS adjust Total Alkalinity TA to 80 180 ppm Calcium Hardness CH to 50 150 ppm then spa water pH to between 7 2 and 7 8 These procedures are listed in the Water Quality and Maintenance section OPERATI...

Страница 11: ...5 volt 20 amp electrical configuration the heating system does not operate simultaneously with the high speed pump On the other hand on the 230 volt system the heating system does operate simultaneous...

Страница 12: ...AdaptaFlo jets 7 AdaptaSsage Jets 8 Outlet for optional ozone 9 Drain suction fitting 10 Pillow 11 Waterfall valve 12 Acquarella Waterfall 13 FROG Palatino Marino 1 1 2 4 7 9 5 1 1 6 10 8 8 9 3 11 12...

Страница 13: ...IT IN THE FILTER COMPARTMENT AREA THIS IS NOT A SEAT Sitting in this area can cause Restriction of filter pump suction vacuum Damage to components Both can result in bodily harm Should damage occur to...

Страница 14: ...r optional ozone 10 Drain suction fitting 11 Pillow 12 Grab Rail 13 FROG aventine 1 2 3 4 6 7 8 7 12 5 11 6 8 10 9 8 13 WARNING DO NOT SIT IN THE FILTER COMPARTMENT AREA THIS IS NOT A SEAT Sitting in...

Страница 15: ...aSsage Jets in back right 2 AdaptaFlo Jets and 1 Euro Jet in right center 4 Euro Jets in footwell PALATINO MARINO System 1 8 Euro Jets in back left 2 AdaptaFlo Jets in back center Acquarella Waterfall...

Страница 16: ...taFlo Jet and 1 AdaptaSsage in front left tarino System 1 Menu A Diverter in position 8 Euro Jets in back left 2 AdaptaSsage Jets in back right Lounge Acquarella Waterfall 2 Euro Jets in footwell 3 Eu...

Страница 17: ...T MENUS 14 AVENTINE System 1 2 Euro Jets in back left 3 AdaptaFlo Jets in back left 2 Euro Pulse Jets in arm rests 4 Euro Jets in back right 2 AdaptaFlo Jets in back right 1 AdaptaFlo Jet in front rig...

Страница 18: ...ystem 1 jet pump runs on high speed 3rd press System 1 System 2 jet pumps run on high speed 4th press System 2 jet pump runs on high speed 5th press Both Systems jet pumps are off Tarino Aventine Spa...

Страница 19: ...ng features SPA Lock and Temperature Lock are enabled from the control panel by pressing the SET button until the Tools menu is illuminated Then press the TEMP button to enter the TOOLS submenus Use t...

Страница 20: ...leep mode to work in the evening hours the spa must be powered up in the early morning hours The Sleep Mode will always be active the 6 12 hours between the end of F2 and the begining of F1 depending...

Страница 21: ...stem ON Press the TEMP button to display PWR and turn the audio system OFF Audio power must be ON to advance to the other audio screens IMPORTANT The power can take up to a few seconds to turn on or o...

Страница 22: ...button to raise the Bass or press TEMP button to lower the Bass TO ADJUST BAlance From the SETUP menu 1 Press the TEMP button to display one of four audio sources IPOD TV AUX BLUE 2 Press the SET but...

Страница 23: ...jets provide a rotating massage pattern Euro Jets The Euro Directional jets with eyeball nozzles deliver a direct more focused massage The Euro Pulse jet features a special insert that creates a soft...

Страница 24: ...ramines and will not alter the water s pH Pathogen A microorganism such as bacterium that cause disease pH The measure of the spa water s acidity and alkalinity The recommended pH for the spa water is...

Страница 25: ...substance can be identified Don t let chemicals get on surrounding surfaces or landscaping Don t use a vacuum cleaner to clean up chemical spills Never smoke around chemicals Some fumes can be highly...

Страница 26: ...lution a mixture of 75 hard and 25 soft water will usually yield a reading within the correct range If soft water is not available or practical for you a stain and scale inhibitor should be added to t...

Страница 27: ...Plus or sodium dichlor chlorine Sodium dichlor may be a more appropriate weekly shock for those users that experience heavy bather load conditions The following optional products can be used in conjun...

Страница 28: ...er to establish the correct setting on cartridges for User Load and Usage Time versus Sanitizer Needed User Load is the spa is the number of times anyone enters the spa Usage Time is simply the amount...

Страница 29: ...n incorrect product such as tri chloro which has a very low pH 2 6 dissolves too quickly in hot water resulting in extremely high levels of chlorine and is designed for concrete or plaster swimming po...

Страница 30: ...em to assure water sanitation and the highest quality of purified water Cleaning the Ozone Injector On occasion a mineral build up may clog the ozone injector causing a lack of flow or low flow of ozo...

Страница 31: ...e chemically induced spa surface blistering chemical abuse very quickly WATER QUALITY AND MAINTENANCE Spa water maintenance troubleshooting guide Cloudy Water Water Odor Chlorine Odor Musty Odor Dirty...

Страница 32: ...ldera Spa Water Maintenance program are needed to protect the user from water borne pathogens disease causing microbes and to prevent corrosion of spa components Question Why isn t water chemistry dam...

Страница 33: ...illow retainers to slip into the recess in the back of the pillow 4 Keeping the pillow slightly bent slide the other pillow retainer into the recess in the back of the pillow 5 After all the pillow re...

Страница 34: ...the outlet of the hose to an appropriate draining area Spa water with a high sanitizer level may harm plants and grass 3 Open the valve by turning the knob The spa will drain by gravitational flow IMP...

Страница 35: ...re install your filter and follow the Start up and Refill Procedures in the Operating Instructions section of the Owner s Manual IMPORTANT Always keep spa covered when not in use whether it is empty...

Страница 36: ...conds to reset the heater high limit If tripping continues clean the filter then if tripping still occurs call for service Water temperature significantly different from display temperature Display sh...

Страница 37: ...pump s to allow the air to escape When water is present hand tighten the union Turn power back on activate the pump and check to make sure union is tight enough to keep it from leaking Re install equi...

Страница 38: ...r purchaser of the Caldera spa when purchased and originally installed within the boundaries of the United States This warranty begins on your delivery date of the spa but in no event later than one y...

Страница 39: ......

Страница 40: ...lbs 120 lbs per Square foot 230 volt 50 amp Single phase GFCI circuit Marino Model MRN 7 0 x 7 0 36 65 square feet 4 000 360 gallons 836 lbs 4 888 lbs 120 lbs per Square foot 230 volt 50 amp Single p...