PRIMINg ThE PUMP(S)
Upon filling or refilling the spa, if a pump is operating and water is not flowing from any of its jets, the pump may not be properly primed. To correct,
refer to the illustration below and perform the following procedures:
• Turn off power to the spa at the breaker and remover the equipment compartment door.
•
loosen
the union on the top of the pump(s) to allow the air to escape. When water is present, hand-tighten the union.
• Turn power back on, activate the pump and check to make sure union is tight enough to keep it from leaking. Re-install equipment door.
NOTe: equipment compartment illustrated below will vary depending on spa model.
PUMP
UNIONS
PUMP
UNIONS
hEATER
UNIONS
dRAIN
PlUg
dRAIN
PlUg
IMPORTANT
ThE dRAIN PlUg ANd UNION FITTINgS IN ThE EQUIPMENT
COMPARTMENT MAY lOOSEN dURINg TRANSPORTATION. TO AvOId
lEAkS, PlEASE ChECk TO MAkE SURE ThESE ARE hANd-TIghT
PRIOR TO FIllINg YOUR SPA.
SPa TrOUBleSHOOTING