background image

Page 14

o

peratInG

 I

nStructIonS

 

MAIN CONTROL PANEL

The main control panel provides a quick visual check of the spa’s status 

and allows the user to set the temperature, activate the jets & lights, lock 

the temperature and/or spa functions. Other optional functions may also 

be available depending on the spa model and accessory equipment that 

has been installed into the spa. The main control panel has eight buttons. 

HARD BUTTONS

The four labeled outer buttons are referred to as "Hard buttons".  These 

buttons are fixed and their functions do not change.

JETS -

 If jet pump indicator light is off and JETS hard button is pressed, 

the 1st jet pump function will activate and the main control panel display 

will advance to the Jets menu.
If jet pump indicator light is on and the JETS hard button is pressed while 

in any screen other than the Jets menu, the jets pump function does not 

change, only the main panel screen will change to the Jets menu.

LIGHTS

 - If lights are off, press LIGHTS hard button from any screen 

to turn on all lights and display the Lighting Options menu. Continue to 

press the LIGHTS hard button to cycle through lights zones.

OPTIONS

 - Transitions to the Options screen to access temperature and 

setup menu

BACK

 - Goes back one menu. In Home screen Hold BACK button until 

screen rotates 180° to view from inside spa. Repeat to reverse.

SOFT BUTTONS

The four inside buttons are referred to as "soft buttons". Pressing a soft 

button will activate the function on the control panel screen closest to that 

button. After a period of non-use (45 seconds) the display will go back to 

the Home screen and will remain on for several minutes before going to 

sleep mode. Pressing any button will wake up a sleeping display.

INDICATOR ICONS

At a glance, the indicator icons are visible on the main control panel. 

The indicator icons work independently from the rest of the control panel 

display. They are displayed so that you may know the status of your spa 

at a glance. NOTE: Indicators will not be visible when Main Control Panel 

goes into sleep mode.

 

READY Indicator:

 The READY indicator will display when the 

spa water temperature is within 1°C (2°F) of the set 

temperature, and will turn off when the temperature is outside of 

that range. If you increase or decrease the temperature setting 

of the spa, the ready indicator will turn off until the water 

temperature reaches the acceptable range for the new 

temperature setting. A flashing READY indicator means a 

problem may exists with the temperature sensor (see 

Troubleshooting section for more information)

Spa Light Indicator:

 The Spa Light indicator is displayed when 

any light inside the spa is on. The indicator icon will remain solid 

as long as any manual light is activated. Spa Light icon will flash 

only when Auto Exterior Light feature is operating the light.

Spa or Temperature Lock Indicator:

 The Spa or Temperature 

Lock indicator is displayed when either the Spa Lock, 

Temperature Lock or both are activated. Lock indicator does not 

flash.

Jet Pump Indicator:

 The Jet Pump indicator is displayed 

whenever a jet pump is on. The Jet Pump indicator will flash 

whenever the spa is in the ten-minute Clean Cycle or Auto 

Clean Cycle.

Summer Timer Indicator:

 The Summer Timer indicator is 

displayed when the summer timer is set to ON. In summer timer 

mode, the heater and circulation pump cycle are off for eight 

hours. The Summer Timer indicator will not flash.

 

POWER Indicator:

 The POWER indicator is ‘on’ when the spa 

is properly supplied with power. It also provides a diagnostic 

function–a flashing power indicator indicates that the heater high 

limit has tripped, meaning that either the spa water is above its 

acceptable temperature range, or a malfunction has occurred 

within the spa (such as low circulation due to clogged filters). 

When the power indicator is not displayed it means that there is 

a problem with the spa control box or the power supplied to the 

spa (see Troubleshooting section for more information).

HOME SCREEN

The temperature displayed in the center of the Home screen is the actual 

temperature of the spa water. If the READY icon is displayed and solid on 

the control panel, then the actual spa temperature is within 1°C (2°F) of 

the set temperature. The corner soft button functions are as follows:

MEMORY

This feature will recall the last active 

setting for jets and lights prior to 

pressing the All Off button.

ALL OFF  

This feature will shut jets, lights and 

audio (if installed) off immediately, while saving the last active jets and 

lights settings.

JETS Hard Button

Soft Button

Soft Button

LIGHTS Hard Button

OPTIONS

Hard Button

BACK

Hard Button  

 

Indicator Icons

Operating Instructions

Содержание Makena

Страница 1: ...PARADISE SERIES 2 0 1 9 O W N E R S M A N U A L 5 0 H z...

Страница 2: ...ERIAL NUMBER ___________________________ COVER SERIAL NUMBER _______________________________ In most cities and counties permits will be required for the installation of electrical circuits or the con...

Страница 3: ...ET SYSTEM MENU 22 REUNION JET SYSTEM MENU 23 KAUAI JET SYSTEM MENU 24 SPA CARE AND MAINTENANCE FILTER MAINTENANCE 25 FILTER CARTRIDGE REMOVALAND CLEANING INSTRUCTIONS 25 DIVERTER VALVE MAINTENANCE 25...

Страница 4: ...ss remote is permitted and acceptable Do not connect any auxiliary components for example cable additional speakers headphones additional audio components to the audio system unless approved by Watkin...

Страница 5: ...evels for your CALDERA spa are Free Available Chlorine 1 5 ppm Total Alkalinity 40 120 ppm Water pH 7 2 7 8 Calcium Hardness Standard 75 150 ppm Salt System 25 75 ppm Refer to Water Quality and Mainte...

Страница 6: ...over the telephone by an Authorized Service Technician SPA SHELL Your CALDERA spa has an acrylic shell Stains and dirt generally will not adhere to your spa s surface Asoft rag should easily remove mo...

Страница 7: ...ition of the nozzle 7 The Euro Directional jets with eyeball nozzles deliver a direct more focused massage 8 The Euro Pulse KAUAI model only jets feature a special insert that creates a soft pulsating...

Страница 8: ...ets allow you to regulate the force of the massage Rotate the fascia ring counter clockwise to reduce the force or clockwise to increase the force Notice that turning off the flow to some jets increas...

Страница 9: ...elivery Before filling the spa wipe the spa shell clean with a soft rag The following instructions must be read and followed exactly to ensure a successful start up or refill CAUTIONS Do NOT fill the...

Страница 10: ...n using the FRESHWATER Salt system the Calcium Hardness must be between 25 75 ppm if hardness is above 75 ppm use VANISHING ACT see pg 11 IMPORTANT Activate the Clean cycle Press the soft button next...

Страница 11: ...in concentrated form Always observe the following guidelines Allow only a responsible person to handle spa chemicals Keep them out of the reach of children Accurately measure the exact quantities spec...

Страница 12: ...use FRESHWATER pH Alkalinity Down sodium bisulfate To raise the pH level use pH Alkalinity Up sodium carbonate Water Conditioners Spa fill water varies from location to location and user to user there...

Страница 13: ...rts water and sodium chloride salt into chlorine sanitizer The FRESHWATER Salt System is compatible with chlorine based systems and chemicals Although the system is reduced maintenance it is not autom...

Страница 14: ...VANISHING ACT calcium remover will be placed up over Use the circle to determine location a Press OPTIONS hard button on the Control panel Press the soft button next to Set Up Press the soft button n...

Страница 15: ...limited warranty Floating dispensers can become trapped in one area and cause an over sanitization or release large chunks of sanitizer that very quickly chemically burn the shell and cover DON T Use...

Страница 16: ...urine perspiration etc Chloramines can cause eye irritation as well as having a strong odor Unlike bromamines chloramines are weaker slower sanitizers Chlorine An efficient sanitizing chemical for sp...

Страница 17: ...range If you increase or decrease the temperature setting of the spa the ready indicator will turn off until the water temperature reaches the acceptable range for the new temperature setting A flashi...

Страница 18: ...Celsius Press the soft button next to the F C to choose one or the other LOCKING FEATURES The two locking features Temperature Lock and Spa Lock are activated at the main control panel Once activated...

Страница 19: ...hut down The circulation pump will remain on for approximately 5 minutes pushing water through the heater to cool it down Both heater and circulation pump will then remain off for eight hours The summ...

Страница 20: ...ake a few seconds to turn on or off TO PAIR BLUETOOTH 1 Press the Function SET soft button 3 times to advance to the Enter Setup screen Press the Enter Setup soft button to advance to the Setup Source...

Страница 21: ...le soft button to advance to the SETUP Tone Bass screen Press SETUP Tone Bass soft button to advance to the SETUP Balance screen Press SETUP Balance soft button to advance to the SETUP Subwoofer scree...

Страница 22: ...NU A Diverter in position a 2 Euro Directional jets b 1 VERSASSAGE jet Located in UltraMassage lounge c 6 Sole Soothers d 3 VERSASSAGE jets e 6 Euro Directional jets COMBINATION JET SYSTEM Diverter in...

Страница 23: ...HORIA jet b 2 Euro Directional jets c 2 Euro Directional jets d 1 VERSASSAGE jet COMBINATION JET SYSTEM Diverter in mid position activates both menus in systems 1 2 SYSTEM 1 MENU B Diverter in positio...

Страница 24: ...Diverter in position Located in ULTRAMASSAGE lounge front a 6 SOLE SOOTHERS b 3 VERSASSAGE jets c 6 Euro Directional jets d Waterfall COMBINATION JET SYSTEM Diverter in mid position activates both me...

Страница 25: ...et Located in ULTRAMASSAGElounge c 2 Euro Directional jets d 3 VERSASSAGE jets a a b c d SYSTEM 1 MENU A Diverter in position Located in ECSTASEAT a 14 Euro Directional jets b 1 ADAPTAFLO jet c Waterf...

Страница 26: ...E jets b 1 ADAPTAFLO jet c Waterfall Located in ECSTASEAT d 2 Euro Directional jets e 2 VERSASSAGE jets SYSTEM 2 MENU A Diverter in position Located in front right seat a 4 Euro Directional jets b 2 V...

Страница 27: ...TASEAT d 8 Euro Directional jets e 2 EURO PULSE jets SYSTEM 1 MENU A Diverter in position Located in ULTRAMASSAGElounge a 6 SOLE SOOTHERS b 3 VERSASSAGE jets c 6 Euro Directional jets Located in LUMBA...

Страница 28: ...ome difficult to turn it is likely that sand or grit is lodged inside the valve body It is very important that this debris is removed as soon as possible to avoid damage to the valve To clean the valv...

Страница 29: ...y warranty It is strongly recommended that you contact your local dealer to perform this service 1 Drain your spa following the Draining Your Spa section in the owner s manual 2 Remove the filter cart...

Страница 30: ...Most household chemicals are harmful to your spa s shell Always rinse off any spa shell cleaning agent with fresh water SPA SKIRT When cleaning the skirt of your spa use only a soft cloth or sponge w...

Страница 31: ...EUNION spas require a dual electrical service using a 16 25 amp breaker and wired per the illustration found on the next page Additionally one main disconnect switch with at least 3mm separation betwe...

Страница 32: ...MM 40 Amp Electrical Requirements HOT HOT NEUTRAL NEUTRAL GROUND RCD BREAKER Tahatian 7 2 3 4 5 6 8 1 EQUIPMENT COMPARTMENT The illustration below is to be used as a reference only your spa may look d...

Страница 33: ...y rot mildew or other problems Check for airborne moisture s effects on exposed wood paper etc in the room To minimize these effects it is best to provide plenty of ventilation to the spa area An arch...

Страница 34: ...ane will be required Don t be alarmed The crane has a truck mounted boom which can fit right in your driveway It is run by a licensed and insured operator For a charge the crane operator will lift you...

Страница 35: ...dead weight found in the spa specification chart WARNING The MAKENA and SALINA must not be shimmed in any manner MAKENA AND SALINA DIMENSIONS NOTE All dimensions are approximate measure your spa befor...

Страница 36: ...upport the dead weight found in the spa specification chart WARNING The MARTINIQUE must not be shimmed in any manner MARTINIQUE NOTE All dimensions are approximate measure your spa before making criti...

Страница 37: ...ck reinforced concrete pad or structurally sound deck able to support the dead weight found in the spa specification chart WARNING The SEYCHELLES must not be shimmed in any manner Installation 33 83 9...

Страница 38: ...10 cm 4 thick reinforced concrete pad or structurally sound deck able to support the dead weight found in the spa specification chart WARNING The REUNION must not be shimmed in any manner 33 83 9 cm...

Страница 39: ...support the dead weight found in the spa specification chart WARNING The KAUAI must not be shimmed in any manner KAUAI NOTE All dimensions are approximate measure your spa before making critical desi...

Страница 40: ...high limit tripping are discussed in the previous section If the spa is not heating the red and green lights are blinking but the pump and light are operating then the pressure switch may be open Open...

Страница 41: ...d warranty lasts Under no circumstances shall Watkins Wellness or any of its representatives be held liable for injury to any person or damage to any property however arising Some states do not allow...

Страница 42: ...set too low Spa cover improperly positioned Dirty filter Summer Timer on Set control panel to a higher temperature Align spa cover Clean filter Turn summer timer mode to off position Pump motor will...

Страница 43: ...notch on other side of panel and place fingers inside the notch and center notch Pull panel away from spa lower panel and store in a cool and shaded place NOTE It may be possible when pulling out the...

Страница 44: ...s 226 cm x 193 cm 7 5 x 6 4 88 cm 34 5 m 3 000 1 080 liters 285 gallons 420 kg 930 lbs 1 895 kg 4 180 lbs 540 kg m 110 lbs ft 220 240 volt 16 25 amp Single phase RCD protected circuit SEYCHELLES Model...