background image

METHODS FOR TESTING THE SPA WATER 

Accurate water testing and analysis is an important part of effectively managing your spa water. You must have the ability to test for:

•   Total Alkalinity (TA)

•   pH

•   Calcium Hardness (CH)

•   Sanitizer

Two types of testing methods are recognized and recommended by Watkins

®

Manufacturing Corporation:

The Reagent Test Kit

is a method which provides a high level of accuracy. The reagents come in either liquid or tablet form.

Test Strips

are a convenient testing method used by many spa owners. Keep in mind that test strips are susceptible to heat and moisture contamination, which will

result in inaccurate readings. 

IMPORTANT:

Always read and carefully follow the directions included with the Test Kit or Test Strips to ensure the accuracy of the test results.

BASIC CHEMICAL SAFETY 

When using chemicals, read the labels carefully and follow directions precisely. Though chemicals protect you and your spa when used correctly, they can be hazardous
in concentrated form. Always observe the following guidelines:

• Allow only a responsible person to handle spa chemicals. 

KEEP THEM OUT OF THE REACH OF CHILDREN

.

• Accurately measure the exact quantities specified, never more. Do not overdose your spa.
• Handle all containers with care. Store in a cool, dry, well ventilated place.
• Always keep chemical containers closed when not in use. Replace caps on their proper containers.
• Don’t inhale fumes or allow chemicals to come in contact with your eyes, nose, or mouth. Wash your hands

immediately after use.

• Follow the emergency advice on the product label in case of accidental contact, or if the chemical is swallowed.

Call a doctor or the local Poison Control Center. If a doctor is needed, take the product container along with you
so that the substance can be identified.

• Don’t let chemicals get on surrounding surfaces or landscaping. 
• Don’t use a vacuum cleaner to clean up chemical spills.
• Never smoke around chemicals. Some fumes can be highly flammable.
• Don’t store any chemicals in the spa equipment compartment.

HOW TO ADD CHEMICALS TO THE WATER

IMPORTANT:

All spa water chemicals, including granulated dichlor, MPS (monopersulphate) granulated pH increaser or decreaser, granulated total alkalinity increaser,

calcium hardness increaser, liquid stain and scale inhibitor, and liquid de-foamer must always be added directly into the filter compartment while the jet pump is running,
and it must run for a minimum of ten minutes. 

To Administer Spa Water Chemicals:

1. Fold back the cover. Carefully remove and set aside the filter compartment cover (if applicable).

2. Press the “JETS” button twice to turn the jet pump on high.

3. Carefully measure the recommended amount of chemical and slowly pour it into the filter compartment. Use care not to splash chemicals on your hands, in your

eyes, on the spa shell surface or on the siding.

4. Replace the filter compartment cover (if applicable). After ten minutes, shut off the jet pump(s) and close and lock the cover to complete the procedure. 

Risk of

Drowning:

Never leave an open spa unattended!

WARNING: 

High sanitizer levels can cause discomfort to the user’s eyes, lungs and skin. Always allow the sanitizer level to fall to the recommended range before

using the spa.

IMPORTANT “SUPER CHLORINATION/NON-CHLORINE SHOCK TREATMENT” NOTE:

After administering a super chlorination treatment or non-chlorine shock to

your spa, leave the cover open for a minimum of 20 minutes to allow the oxidizer gas to vent. A high concentration of trapped oxidizer gas which may exist as a result of
the shock treatment (not daily sanitation) may eventually cause discoloration or vinyl degradation to the bottom of the cover. This type of damage is considered chemical
abuse and is not covered under the terms of the limited warranty.

THE WATKINS

®

SPA WATER MAINTENANCE PROGRAM

Each step in your water maintenance program is dependent on the completion of the previous steps. Omitting a step or failing to reach the recommended range may
cause an imbalance in your water’s chemistry. Unbalanced water chemistry can damage the spa and its components, as well as cause discomfort for the user.

BALANCING THE TOTAL ALKALINITY (TA)

A. The recommended Total Alkalinity (TA) for your spa water is 125-150 ppm.

B. Total Alkalinity is a measure of the total levels of carbonates, bicarbonates, hydroxides, and other alkaline substances in the water. TA is referred to as the water’s

“pH buffer”. In other words, it’s a measure of the ability of the water to resist changes in pH level.

C. If the TA is too low, the pH level will fluctuate widely from high to low. Fluctuations in pH can cause corrosion or scaling of the spa components. 

Low TA can be

WATER QUALITY AND MAINTENANCE

13

ALKALINE

SPA

WATER

(SCALING

ZONE)

ADD pH

DECREASER

TO LOWER

pH

ACIDIC

SPA

WATER

(CORROSIVE

ZONE)

ADD pH

INCREASER

TO RAISE

pH

COMFORT

ZONE

IDEAL

Содержание Highland Series

Страница 1: ...Olympia Cumberland AventineTM Highland Series Owner s Manual ...

Страница 2: ... SPA MODEL SERIAL NUMBER ______________________________ COVER SERIAL NUMBER ____________________________________ In most cities and counties permits will be required for the installation of electrical circuits or the construction of exterior surfaces decks and gazebos In addition some communities have adopted residential barrier codes which may require fencing and or self closing gates on the prop...

Страница 3: ...AINTENANCE General Information 12 Methods for Testing the Spa Water 12 The Watkins Spa Water Maintenance Program 13 Chlorine sodium dichlor 15 Monarch Ozone System Optional 17 PureWater Ozone System Optional 17 Common Water Chemistry Questions 18 Water Terminology 18 Spa Water Maintenance Troubleshooting Guide 19 MAINTENANCE Filter Maintenance 20 Care of the Spa Pillows 20 Care of the Exterior 21 ...

Страница 4: ...ment protection To ensure proper operation of this important safety device test according to the following instructions per electrical configuration Cord Connected 115 volt 20 amp models The GFCI is located at the end of the power cord Before each use with the unit operating push the TEST button The unit should stop operating and the GFCI power indicator will go out Wait 30 seconds and then reset ...

Страница 5: ...spa if the suction fittings are broken or missing People with infectious diseases should not use the spa Keep any loose articles of clothing or hanging jewelry away from rotating jets or other moving components Increased side effects of medication The use of drugs alcohol or medication before or during spa use may lead to unconsciousness with the possibility of drowning Persons using medications s...

Страница 6: ...Lift or drag the cover by using the cover lock straps always lift or carry the cover by using the handles Attempt to open the electrical control box There are no user serviceable parts inside Opening of the control box by the spa owner will void the warranty If you have an operational problem carefully go through the steps outlined in the Troubleshooting section If you are not able to resolve the ...

Страница 7: ...iratory infection If you or other bathers are affected by this condition please seek medical attention as soon as possible In addition to the above properly clean and maintain your spa as follows Follow all procedures in this owner s manual and printed instructions on all water care chemical products packaging Test the water regularly to ensure proper levels of sanitizers pH and other water care r...

Страница 8: ...rician A wiring diagram is provided inside the equipment module showing where the connections are to be made ELECTRICAL REQUIREMENTS AND PRECAUTIONS Your Caldera spa has been carefully designed to give you maximum safety against electrical shock Connecting the spa to an improperly wired circuit will negate many of the spa s safety features Improper wiring may also cause electrocution risk of fire ...

Страница 9: ...he Neutral terminal on the spa s control box 6 Connect the 8 AWG BLACK L1 wire from the subpanel breaker to terminal L1 on the spa s control box 7 Connect the 8 AWG RED L2 wire from the subpanel breaker to terminal L2 on the spa s control box 8 Connect the 8 AWG GREEN wire from the subpanel GRD to the GROUND terminal of the spa s control box 9 Bond the spa to all exposed metal equipment or fixture...

Страница 10: ...intenance section IMPORTANT Activate the Clean cycle Press SET then JETS button before adding spa water chemicals directly into the filter compartment OPERATION NOTE Adjusting the Total Alkalinity as the first step is important as out of balance TA will affect your ability to adjust the pH correctly and will prevent the sanitizer from operating effectively 5 Activate the Clean cycle then superchlo...

Страница 11: ...ter compartment 4 Temperature sensor 5 Spa light 6 Drain suction fitting OLYMPIA MODEL OLY 7 Outlet for optional Ozone 8 Magna Jets 9 Euro Directional Jets 10 Pillow 11 Waterfall Valve 12 Waterfall Feature 1 1 2 4 7 9 10 5 8 1 1 6 10 10 6 6 8 8 8 9 9 9 3 11 12 ...

Страница 12: ... Jets 8 Magna Jets 9 Outlet for optional Ozone 10 Drain suction fitting 11 Pillow 13 Grab Rail 1 2 3 4 6 7 8 7 12 5 11 2 3 4 7 10 5 8 1 6 6 8 9 11 CUMBERLAND MODEL CUH 1 Air control 2 Spa side control panel 3 Spa light 4 Filter compartment 5 Temperature sensor 6 Euro Directional Jets 7 Magna Jets 8 Diverter Valve 9 Outlet for optional Ozone 10 Drain suction fitting 11 Pillow 7 7 3 1 6 8 10 9 8 ...

Страница 13: ...perature will increase by one degree every half second When the set temperature has been reached the READY icon will diplay Pressing the TEMP button displays the spa s set temperature To decrease the set temperature press the TEMP button again once for each degree of decreased temperature desired If you hold the button down the set temperature will decrease by one degree every half second When the...

Страница 14: ...ally turn the filter cycle on twice each day When the spa is first powered up the automatic filter cycle will wait 10 minutes before starting A 1 5 hour filter cycle using the low speed of the jet pump is the programmed default filter cycle time The display will read 1 30 The filter cycle occurs twice a day every 12 hours NOTE The optional Monarch and PureWaterTM ozone systems only work during the...

Страница 15: ... can be accomplished by simply twisting off the Euro jet face adding the nozzle and nozzle retainer then reinstalling the Euro jet face DIVERTER VALVE The diverter valve on the Cumberland spa model allows you to direct the flow of water from the pump to several combinations of jets The functions of this diverter valve can best be learned by experimentation as follows 1 Set all air controls to the ...

Страница 16: ... be added directly into the filter compartment while the jet pump is running and it must run for a minimum of ten minutes To Administer Spa Water Chemicals 1 Fold back the cover Carefully remove and set aside the filter compartment cover if applicable 2 Press the JETS button twice to turn the jet pump on high 3 Carefully measure the recommended amount of chemical and slowly pour it into the filter...

Страница 17: ... the effectiveness of the sanitizer Maintaining water that is comfortable for the user Preventing equipment deterioration C If the spa water s pH level is too low the following may result The sanitizer will dissipate rapidly The water may become irritating to spa users The spa s equipment may corrode If the pH is too low it can be increased by adding sodium hydrogen pH Alkalinity Up carbonate to t...

Страница 18: ...y shock for those users that experience heavy bather load conditions IMPORTANT NOTE MPS is an oxidizer not a sanitizer MONARCH SILVER ION PURIFIER INSTALLATION INSTRUCTIONS When replacing the silver ion purifier every four months it is highly recommended that the spa be drained and refilled at the same time After refilling the spa with water balance the Total Alkalinity TA Calcium Hardness CH and ...

Страница 19: ...idizer for spas only DO store all chemicals in a tightly sealed container in a cool dry place DON T use bromine sodium bromide or biguanides These are an active sanitizer and will combine with the silver ions to inactivate them DON T use a water clarifier Clarifiers will cause the spa water to become cloudy CHLORINE SODIUM DICHLOR A Sanitizing chemicals such as chlorine are oxidants that kill bact...

Страница 20: ...ENANCE Proper water sanitation and mineral balance pH control are absolutely essential for a complete spa water maintenance program Here are three other popular water additives that are optional Mineral Deposit Inhibitors As water evaporates from your spa and new water is added the amount of dissolved minerals will increase Minimize evaporation by keeping the cover on the spa whenever possible The...

Страница 21: ...ter Cleaning the Ozone Injector On occasion a mineral build up may clog the ozone injector causing a lack of flow or low flow of ozone bubbles To prevent this refer to the following instructions to clean the injector 1 Disconnect power to the spa 2 Access the equipment compartment 3 Locate the ozonator in the equipment compartment and unplug the ozonator from the control box 4 Place 16 ounces of w...

Страница 22: ...s type of highly concentrated chemical Remember chemical abuse is specifically not covered under the terms of the warranty Question When I open my spa I smell chlorine How do I get rid of this smell Answer There are two types of chlorine in your spa The first is the Free Available Chlorine which is the chlorine available to sanitize your spa This free Available Chlorine does not have an odor The s...

Страница 23: ...known as super chlorination when chlorine is used Shock treatment is a process of adding significant doses of a quick dissolving sanitizer sodium dichlor is recommended to oxidize non filterable organic waste and to remove chloramines and bromamines Total Alkalinity The amount of bicarbonates carbonates and hydroxides present in spa water Proper total alkalinity is important for pH control If the ...

Страница 24: ...ter then replace basket and weir by inserting and rotating clockwise to lock into position CARE OF THE SPA PILLOWS Spa pillows will provide years of comfort if treated with care They have been positioned above the water level to minimize the bleaching effects of chlorinated water and other spa water chemicals To extend their life whenever the spa shell is being cleaned the spa pillows should be re...

Страница 25: ...cleaners out of the reach of children and use care when applying CARE OF THE SPA COVER WARNING The cover is a manual safety cover that meets or exceeds all prevailing requirements of ASTM Standards for spa safety covers when installed and used correctly as of the date of manufacture Non secured or improperly secured covers are a hazard Open the cover to its fully open position before use VINYL COV...

Страница 26: ...REEZING TEMPERATURES DO NOT OCCUR it may be desirable to turn the heater to the lowest temperature The automatic filter cycles will keep the spa water clean and sparkling When preparing the spa for use check the water chemistry to assure correct chlorine or bromine and pH levels You can keep the water in the spa during the time of year when freezing at the spa location may occur If a freeze condit...

Страница 27: ...suse and abuse shall include any operation of the spa other than in accordance with Watkins Manufacturing Corporation printed instructions or use of the spa in an application for which it is not designed specifically use of the spa in a non residential application damage caused by operation of the spa at water temperatures outside the range of 35 F and 120 F damage caused by a dirty clogged or cal...

Страница 28: ...ot reset check for clogged filter If tripping continues call for service Check for clogged filter The pressure switch will reset when the flow of water through the heater has been restored Call for service if the pressure switch trips frequently Contact an Authorized Service Technician Add water Clean filters Clean suction screens Open jet nozzles Open air valve Contact an Authorized Service Techn...

Страница 29: ...NOTES 26 ...

Страница 30: ...NOTES 27 ...

Страница 31: ...NOTES 28 ...

Страница 32: ...eer or contractor be consulted before the spa is placed on an elevated deck NOTE The Filled weight and Dead weight of the spa includes the weight of the occupants assuming an average occupant weight of 175 lbs 5 4 x 5 4 AventineTM 29 35 square feet 1 000 or 4 000 150 gallons 395 lbs 2 020 lbs 80 lbs per square foot 115 volt 20 amp Dedicated GFCI protected cord or 230 volt 50 amp Single phase GFCI ...

Отзывы: