SR
-SERIES
54
COMBUSTION AIR HORIZONTAL
HORIZONTAL
COMBUSTION AIR VERTICAL
VERTICAL
Figure 53. OUTSIDE COMBUSTION AIR SUPPLY
40,000
–
150,000 Btu/hr input
MAXIMUM LENGTH IS 45' (13.7m)
MINUS EXHAUST VENT LENGTH.
DEDUCT 10’ (3m) FOR EVERY 90
°
ELBOW USED AND 5’ (1.53m) FOR
EVERY 45° ELBOW USED.
175,000
–
200,000 Btu/hr input
MAXIMUM LENGTH IS 30' (9.1m). TOTAL LENGTH OF HEATER
INCLUDING THE LENGTH OF OUTSIDE COMBUSTION AIR
(INTAKE) DUCT AND EXHAUST VENTING IS NOT TO EXCEED
110’ (33.6m). SHORTEN DUCT LENGTH BY 10’ (3m) FOR EVERY
90° ELBOW USED A
ND 5’ (1.53m) FOR EVERY 45° ELBOW USED.
36” (92cm) MAXIMUM
FLEXIBLE DUCT LENGTH
FRESH AIR INTAKE HOOD
4” (10.2 cm
)
40,000
–
80,000 input
6” (15.3 cm)
100,000
–
200,000 input
Содержание SR Series
Страница 17: ...SR SERIES 13 8 0 PACKAGING CONTENTS DESCRIPTION OF PARTS BURNER PACKAGE Figure 10 BURNER PACKAGE CONTENTS...
Страница 18: ...SR SERIES 14 PIPE BOXES Figure 11 PIPE BOX CONTENT...
Страница 19: ...SR SERIES 15 10 3 M REFLECTOR PACKAGE Figure 12 10 3 M REFLECTOR PACKAGE CONTENTS...
Страница 20: ...SR SERIES 16 15 4 16 M REFLECTOR PACKAGE Figure 13 15 4 16 M REFLECTOR PACKAGE CONTENTS...
Страница 21: ...SR SERIES 17 20 6 1 M REFLECTOR PACKAGE Figure 14 20 6 1 M REFLECTOR PACKAGE CONTENTS...
Страница 22: ...SR SERIES 18 30 9 1 M REFLECTOR PACKAGE Figure 15 30 9 1 M REFLECTOR PACKAGE CONTENTS...
Страница 23: ...SR SERIES 19 40 12 2 M REFLECTOR PACKAGE Figure 16 40 12 2 M REFLECTOR PACKAGE CONTENTS...
Страница 24: ...SR SERIES 20 50 15 2 M REFLECTOR PACKAGE Figure 17 50 15 2 M REFLECTOR PACKAGE CONTENTS...
Страница 25: ...SR SERIES 21 60 18 3 M REFLECTOR PACKAGE Figure 18 60 18 3 M REFLECTOR PACKAGE CONTENTS...
Страница 26: ...SR SERIES 22 70 21 3 M REFLECTOR PACKAGE Figure 19 70 21 3 M REFLECTOR PACKAGE CONTENTS...
Страница 27: ...SR SERIES 23 80 24 4 M REFLECTOR PACKAGE Figure 20 80 24 4 M REFLECTOR PACKAGE CONTENTS...
Страница 28: ...SR SERIES 24 10 3 M EXTENSION KIT Figure 21 10 3 M EXTENSION PACKAGE CONTENTS...
Страница 29: ...SR SERIES 25 SIDE REFLECTOR PACKAGE Figure 22 SIDE REFLECTOR PACKAGE CONTENTS...
Страница 30: ...SR SERIES 26 90 ELBOW PACKAGE Figure 23 90 ELBOW PACKAGE 180 U BEND PACKAGE Figure 24 180 U BEND PACKAGE...
Страница 34: ...SR SERIES 30 HORIZONTAL INSTALLATION 10 3 M REFLECTOR PACKAGE Figure 28 HORIZONTAL INSTALLATION 10 3 M PACKAGE...
Страница 56: ...SR SERIES 52 SIDE REFLECTOR Figure 52 SIDE REFLECTOR INSTALLATION...
Страница 62: ...SR SERIES 58 ROOF EXHAUST Single Unit Use B style chimney SINGLE UNIT INTO ONE 1 B Vent Chimney...
Страница 78: ...SR SERIES 74 24 0 GAS VALVES Figure 62 GAS VALVE Figure 63 PRESSURE REGULATOR...
Страница 94: ...SR SERIES 90...
Страница 95: ...SR SERIES 91...