To trace an activity:
1.
Use Category 5 or better Ethernet cable to connect the correct computer Ethernet port to the transceiver’s
MAINT
port.
2.
The Ethernet port must be configured to communicate with the
MAINT
port. See
D.1 To Configure the Computer
Ethernet 1 Interface for Communication with the Transceiver MAINT Port
.
3.
On the computer, open the
XtermW
application.
4.
Specify the transceiver port you want to communicate with: Click
Send
, click
Command
, and then type:
TRACE,port,maint
where:
TRACE
is the trace command,
port
is a subcommand, and
maint
refers to the
MAINT
port.
5.
Click
OK
.
6.
Select the trace feature and output destination: Click
Send
, click
Command
, and then type:
TRACE,level,feature,destination
where:
TRACE
is the trace command,
level
is a number from
0
to
7,
feature
is the name of the feature you want to trace, and
destination
is the location of the trace output, which can be port, file, or both. If you do not enter a
destination, the trace output is sent to the port only.
7.
Click
OK
.
To suspend a trace:
1.
In
XtermW
, click
Send
, Click
Command
, and then type:
TRACE,SUSPEND
2.
Click
OK
.
To resume a trace:
1.
In
XtermW
, click
Send
, click
Command
, and then type:
TRACE,RESUME
2.
Click
OK
.